Measuring Specialist
Based on ISO 9001:2015Calibration lab ILAC ISO/IEC 17025
Factory automatic QC inspection system IEC 61298
ILAC | TAF ( ISO / IEC 17025 )Accredited No. 3032Air Velocity Standard Calibration Laboratory
Accredited capabilities ● Air velocity : 0.2 . . . 6 0 m / s;Smallest Uncertainty:0.08 m/s ... 0.63 m/s
● Low uncertainty, quickly repeat testing, suitable for calibration of the air velocity transmitter
eYc Brand Concept"eYc" is developed with the core concept "Precision, Professionalism and Stability" Our product application in refrigeration, HVAC, pharmaceutical, greenhouse, environmental engineering, food, hospitals, agro-industry, heavy industry and other related industries. We start from Taiwan and then move forward into the world over, with this vision, to develop Innovative products and service, and also try to do best to create our core competency along with the utmost value for our customers and the society.
eYc’s core professional calibration laboratory, include temperature and humidity, dew point, air velocity, flow rate, pressure. The calibration is based on references, which are traceable to national or international measurement standards, also we work according to EN ISO/IEC 17025 standard. All of our calibration laboratory certified by TAF (ISO / IEC 17025) (Accreditation No.3032)The National Accreditation Foundations (TAF) a certification body, accredited by the International Laboratory Accreditation Alliance (ILAC), has signed an inspection mutual recognition agreement with ILAC. It provides accurate calibration services through TAF on behalf of Internationally recognized grade standards and can be traced back to the SI unit. Our calibration laboratory has the measurement uncertainty evaluation report and calibration procedures for each system We believe that after our service will help our clients to maintain the best quality and stability of your sensor and instrumentation standards.
Measuring Specialist
FTM09 Thermal Mass Gas Flow Meter ControllerSensor:Pt20 / Pt1000;Pt20 / Pt300
Medium:Applicable to various gases such as natural gas, including dust, sand,
moisture and other corrosive gases (except acetylene gas)
Medium range:0 ... 200°C
Accuracy:1.0% / 1.5% / 2.0%
Turndown ratio:100:1
Output:4 ... 20mA、RS-485、Pulse;HART
LED;RS-485 ,HART
Multiple mode switching:temperature, wind speed, air volume, cumulants, physical ,
RS-485 digital, analog output
Self-test function for maintenance and commissioning
FTM06 Hot Wire Thermal Air Velocity TransmitterSensor:Resistance temperature detector (RTD)
Range:0 ... 60 m/s (Air)
Medium:Gas which is compatible with stainless steel
Output:Analog:4 ... 20mA / 0 ... 10V / RS-485;3-wire
Accuracy:3% < 60 m/s
IP rating:IP67
Analog and RS-485 output
Applicable micro corrosion air
Strong stainless steel housing, for a variety of harsh environments
Built-in with temperature compensation, accommodate quickly any environment
Application: Food / Chemicals / Pharmaceuticals / Biotechnology industries
FTM84/85 Industrial Grade High Accuracy Thermo Air Velocity Transmitter
Sensor:Thermal mass flow sensor
Range:1 m/s;2 m/s;5 m/s;10 m/s;20 m/s;40 m/s;60 m/s;90m/s;120m/
Temp. Sensor / Measuring range:Pt1000, 0 ... 80°C
Accuracy( + 25°C ):Air velocity:± 1.5 % F.S.
Temperature ( > 2 m / s ):± 0.3°C
Output:0 ... 20 mA / 4 ... 20 mA / 0 ... 1 VDC / 0 ... 5 VDC / 0 ... 10 VDC;3-wire
IP rating:IP65
Monitor air velocity in supplying gas, consumption, and dry process in industry process
Application:Compressed air consumption / Measurement / Building / Factory / Cleanroom / Hospitals /
Semiconductor / Electronics / Paper / Printing / Textiles / Steel and iron industry
Measuring Specialist
Product with provide additional option (ILAC/TAF) test report
Preliminary productfor water measurement
FTS14 Air Velocity Transmitter ( OEM )Sensor:Thermal mass flow sensor
Range:20 m/s
Min. range:0.2 m/s
Medium:Air
Accuracy ( +25°C ):± 5 % F.S.
Output:4 ... 20 mA / 0 ... 10 VDC;3-wire
Electrical Connection:Terminal
IP rating:IP54
Housing:PC fire-proof ( UL94V-2 )
Temperature compensation, linear adjustment function
Switching analog output by dip switch
Off set function by button
FTS34/35 Thermo Air Velocity TransmitterSensor:Thermal mass flow sensor
Range:2 m/s;10 m/s;20 m/s;40 m/s
Min. range:0.2 m/s
Medium:Air
Accuracy ( + 25°C ):± 2 % F.S.
Output:4 ... 20 mA / 0 ... 10 VDC;3-wire
Electrical connection:Terminal / M12 connector
IP rating:IP54
Housing:PC fire-proof ( UL94V-2 )
Measuring Specialist
DPMF-M9 Flow MeterRange:-999999 ... 999999 ( Instantaneous flow );0 ... 99999999.9999 ( Totalizer )
Accuracy:±0.2% F.S.;frequency:± 1 pulse (LMS),better than 0.2%
Output Analog / Communication / Switch;Input:Analog/Pulse
Full range of automatic temperature and pressure compensation calculation,
compensation mode can be set arbitrarily. Linear calculation, square root calculation
arbitrary setting. Instantaneous flow, cumulative flow, temperature, pressure, multiple
parameters display. Small signal removal function. The accumulated flow value can be
reset through the panel key, and the reset operation can be locked. The accumulated flow
value can be reset through the panel key, and the reset operation can be locked. With power-off
memory function, the accumulated flow value can be maintained for more than 5 years, and all
set values are permanently saved after power-off.
Applications:Petroleum / Chemical / Marine / Pharmaceutical / Papermaking / Food and energy / Industrial processes /
Chemical industrial processes / High pressure gas storage and injection / Natural gas / Batch control / Mixing /
Process control / Filling and dosing
P064 Digital Differential Pressure / Pressure TransmitterMedium:Gas, Steam, Liquid level
Range:MAX.30bar;Min. -1bar
Pressure type:Relative pressure, Absolute pressure, Differential pressure
Accuracy:±0.075%F.S.;±0.1%F.S. ( typ. );±0.2%F.S.
Output:4 ... 20mA 、 4 ... 20mA+HART® ( 10.5 ... 36V, typical 24V )
IP Rating:IP65
Housing:SUS316
High accuracy, good stability, stainless steel housing
Strong resistance to frequency conversion interference
Monocrystalline silicon differential pressure sensor
Application:Petroleum / Chemical / Metallurgy / Electric power / Food / Papermaking / Medicine /
Machinery manufacturing / Scientific experiments / Aviation and military
AFMS-160 S-type Pitot TubeOperating pressure:Max. 10 bar
Operating temperature:Max. 800°C
Medium / Coefficient:Air / Flow Coefficient ( K ):0.84
Mounting:Tube type
Material:Copper or stainless steel ( Optional )
Connecting pipe length:25...1500mm ( Customization )
Stainless steel, high temperature, corrosion resistant
Large, open tip design resists fouling
Can be used in harsh environments, exhaust gas emission,
environmental protection engineering
Connect with eYc pressure transmitter PHM33/P064 to measure
the dynamic pressure(ΔP) of the airflow in the pipeline and calculate
the air velocity and air volume and temperature
PHM33 Industrial Grade Differential Pressure TransmitterSensor:Thermo differential pressure
Range:0 ... 500 pa
Accuracy ( at 25°C ):± 0.5 % of F.S.
Output:0 ... 20mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 1 ... 5V / 2 ... 10V / 0 ... 10V;3-wire
IP rating:IP65
Zero point stability and small differential pressure detection capability,
high pressure resistance
Square root function
Application:Cleanroom / Hospital / Air duct / Filter environment and monitor air flow
Measuring Specialist
The basic principle of a hot wire anemometer is to place a thin metal wire in a fluid, and heat the metal wire ( hot wire) by
current to make it temperature higher than the temperature of the fluid, when the fluid flows in vertical direction through
the wire, a part of the heat of the wire is taken away, and make the temperature of the wire is lowered.
The heat dissipated in the airflow is related to the flow rate. The heat dissipation causes the temperature of the hot wire
to change, causing a change in resistance, the flow rate signal to be converted into an electrical signal.
AFMT Average Flow Measuring Tube ( Pitot tube )Operating pressure:Max. 10 bar
Operating temperature:Max. 250°C
Medium / Coefficient:Air / Flow coefficient ( K ):1
Mounting:Tube type;Material:Measuring tube SUS316
Connection:Copper or stainless steel ( Optional )
Connecting pipe Length:100 ... 1000mm( Customization )
Stainless steel housing, high temperature resistant, corrosion resistance,
dust resistance, can measure micro flow rates
Applied in harsh environments, exhaust gas emission, environmental
protection engineering,installation location is not restricted
If connect with eYc micro differential transmitter PHM33 or PMD33
Can be customized according to customer needs
PMD33 Differential Pressure TransmitterSensor:Piezoelectric differential pressure
Range:±50 ... ±2500 pa;Medium:Air
Accuracy ( at 25°C ):± 2.0 % of F.S
Output:0 ... 20mA / 4 ... 20mA / 0 ... 1V / 0 ... 5V / 1 ... 5V / 2 ... 10V / 0 ... 10V;3-wire
IP rating:IP65
Zero point stability and small differential pressure detection capability, high pressure resistance
Square root function
Physical quantity switch:mbar / Pa / hPa / kPa / mmH2O / mmWS / inH2O / mmHg
| Application Principle |
The chemical industryAmmonia gas measurement in chemical fertilizer plant;Various gas flow measurement in battery factory;Gas flow measurement in sampling system;Gas flow measurement of induced draft fan;Smoke cycle monitoring
Metallurgical industryMeasurement and control of heating furnace gas (blast furnace gas, coking gas, natural gas, etc.) in rolling mills;Control of hydrogen, oxygen, nitrogen and other gases in heat treatment quenching furnace;Gas metering in steel works;Measurement of coke oven gas in coking and iron works
The power industryHydrogen measurement;Measurement of primary and secondary air in blast furnace of power plant;Gas measurement during gas distribution in fuel system;Measurement of various gases in boilers and auxiliary systems;Measurement of gas in a gas furnace
Environmental protectionMeasurement of the aeration tank in the process of sewage treatment;Monitoring the discharge of SO2 and NOX;Gas measurement in biogas utilization process;Measurement of chlorine gas during chlorine treatment
Food and drug industry Carbon dioxide treatment in breweries;Measurement of gas flow during thermal oxidation;Ventilation system;The addition of fresh air during processing;Boiler intake, exhaust gas, process control
Pulp and paper industry Measurement of gas and air supply for boilers;Measurement of gases in wastewater treatment systems;Flue flow monitoring;Boiler recovery secondary/tertiary air
Oil and gas industry Energy exchange;Natural gas measurement;Torch gas monitoring;Well filling gas recovery;Fuel gas metering;Gas mass analysis;Leakage gas test
Other Pipeline and industrial process;Factory compressed air measurement;Coal combustion process powder/gas ratio control fuel;Control of hot air discharge from vertical mill in cement industry
Measuring Specialist
www.eyc-tech.comTel.:+021- 54887307 诚田自动化仪表(上海)
info@eyc-tech.com
Your solution provider
www.eyc-tech.comTel.:+886-2-8221-2958
info@eyc-tech.com
ServiceGreat solutionQuick delivery
After-sales service
ProductionInternational certification
Strict quality checksAutomatic production
Customization
ProductInnovative design
High-performance R&D teamCore patent
LaboratoryILAC /ISO/ IEC17025
Professional calibration techniqueHigh grade equipment
Recommended