H i g h P e r f o r m a n c e E x t e r i o r S h e a t h i n g
CertainTeed
Est. 1665
2015®
CertainTeed respects the environment through the responsible development of sustainable building products and systems.
By utilizing Building Science,
and by taking a life cycle
perspective, our products
and systems are
manufactured to meet the
high-performance demands
of today’s buildings, as well
as to reach even higher
goals for the future. By
working with others, we’re
demonstrating that we are
genuine advocates of
building responsibly.
2
GlasRoc® Sheathing is a high performance,
water resistant, gypsum-based exterior
sheathing.
GlasRoc Sheathing offers a patented
technology of a high performance polymer
coating on reinforcing glass mat facers.
This unique coating provides a superior
water and UV resistant surface for long term
protection to weather exposures.
The “paperless” glass mat facers are
embedded into a water resistant gypsum core,
and positioned beneath a polymer modified
gypsum surface.
GlasRoc Sheathing offers:
• Long term protection (12 months) to
weather exposure.
•Asuperiorwaterresistantsurfacethat
does not inhibit water vapor permeance.
•Excellentfireresistanceproperties,
and numerous fire rated designs.
•Moldresistance.
•Durability-resistsdelaminationdueto
embedded glass mat in the gypsum core.
• Strength – with enough flexibility to bend
to curved surfaces.
• Alightweightsheathingthatcutslike
regular gypsum board and is easy to handle
andinstall–withminimalskinirritationdue
to embedded glass mats.
•Conformity to design and code requirements.
GlasRoc Sheathing is the next generation
of the industry standard for high-performance,
weather-resistive, gypsum-based sheathing.
Tobackitup,CertainTeedprovidesa:
•12 month limited warranty against exposure
•5yearlimitedwarrantyassuringproduct
performance
•12 year substrate limited warranty in
architecturally-specifiedEIFSystems
High performance polymer coating bonded to a polymer-modified gypsum surface
Reinforcing glass mats embedded beneath a polymer-modified layer of gypsum
Specially formulated water resistant core
A High Performance Exterior Sheathing*
* Covered by U.S. Patent No. 6,524,679; 6,878,321;
6,866,492, and other patents pending.
CoverPhoto:TheAvenueatWestchase,Tampa,FL
Architect:NathanGriffesCuhaci&Peterson
GeneralContractor:SikonConstruction,BocaRaton,FL
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com 3
Contents:Introduction.................................................... 2
ApplicationsDiagram .................................... 3
GlasRoc Benefits.......................................... 4
Physical Properties ........................................ 5
ExteriorWallSystems ................................... 6-9
ExteriorDesigns(Arches/Soffits) ................... 10-11
Fire-RatedExteriorWallSystems ................. 12-18
Fire-RatedInteriorSystems .......................... 19-20
Fastening ....................................................... 21
Framing&JointTreatment ........................... 21
Warranty ........................................................ 22
ArchitecturalSpecifications ........................... 23
ContactInformation ....................................... 24
GlasRoc® Sheathing Fire Resistive Applications:
FireResistanceRated MetalStudSystemsSee Pages 12-15
FireResistanceRated WoodStudSystemsSee Pages 16-17
FireResistanceRated Floor/CeilingSystemsSee Page 18
FireResistanceRated SteelBeam&ColumnSee Page 19
GlasRoc Sheathing Applications
NOTE: All drawings are for illustration purposes only.
ExteriorInsulation& FinishSystems(EIFS)
See Page 6
ExteriorArchways, Convex or Concave Surfaces
See Page 10
Conventional StuccoSee Page 8
CavityWallSee Page 7
ExteriorSoffitsSee Page 11
ExteriorCladdingSee Page 9
GlasRoc® SheathingBenefits
4
Thickness & Type Width Length Edge Standard
1/2” (12.7 mm) GlasRoc® Sheathing 4’ 8’* Square ASTMC1177
5/8” (15.9mm) GlasRoc® Sheathing Type X 4’ 8’* Square ASTMC1177
* Otherlengthsavailable.AskyourCertainTeedsalesrepresentative.
Dimensions
Better Physical Performance
TestedinaccordancewithASTMC1177,
andapplicableASTMC1396sections,
GlasRoc® Sheathing meets or exceeds all
physical property req uirements. Results
showed improved physical performance
compared to glass-faced gypsum
sheathingincluding:
•Reducedhumidifieddeflections
•Superiorflexuralstrengths
•Excellentnail-pullresistance
Enhanced Dimensional Stability
GlasRoc Sheathing will withstand normal
exposure to UV, rain, wind, ice, and snow.
Itisdimensionallystableunderchangesin
temperatureandrelativehumidity.Toback
it up, CertainTeed provides a 12 month
exposure limited warranty.
Excellent Fire Protection
TestinginaccordancewithASTME136
(CAN/ULC-S114)provedthatGlasRoc
Sheathing, with its polymer coating, is
noncombustible and offers superior fire
performance compared to paper-faced
sheathings.Ithasazeroflamespreadand
zerosmokedevelopedindex when tested per
ASTME84(5/5whentestedperCAN/ULC-S102)
for surface burning characteristics.
GlasRoc Sheathing Type X is UL and ULC
ClassifiedforFireResistanceforuseinfire-
rateddesigns.(ULandULCDesignation-
TypeEGRGorGlasRoc).
Easy to Handle and Install
GlasRoc Sheathing is handled and installed
likeregularpaper-facedsheathing.In
addition,it:
•Canbescoredandcutwithastandard
utilityknife.Nospecialtoolsrequired.
•Snapsfreeafterscoringonlytheface.
•Attachestoframingwiththesame
fasteners used for paper-faced gypsum
sheathing.Nospecialfastenersrequired.
•Iseasiertohandlebecauseskin
irritationsareminimizedduetothe
embedded glass mats and our innovative
polymer coating.
•Hasuniformfieldandedgehardness,
makingtrimming&fasteningquick
and easy.
Long Term Protection to
Weather Exposure
GlasRoc Sheathing, with its homogenous
water resistance throughout the board,
offerssuperiorfreeze/thawresistance.It
will withstand exposure to UV, rain, wind,
iceandsnow.Tobackitup,CertainTeed
provides a 12 month exposure limited
warranty. GlasRoc Sheathing provides
enhanced surface liquid water resistance
while allowing the building’s vapor drive to
be unimpeded.
Mold Resistance
BecauseGlasRocSheathingcontains
no starches or sugars, it will resist
mold growth. Whentestedin accordance
withASTMD3273,GlasRocSheathing
exhibited no evidence of mold or fungal
growthafteraperiodof28daysof
exposure,yieldingaratingof10.
Increased Durability
GlasRoc Sheathing resists delamination
because the glass mats are embedded
into the panel, creating a more durable,
dimensionally stable panel.
Standards and Code Compliance
GlasRoc Sheathing conforms to
ASTMC1177,applicableASTMC1396and
CAN/CSA-A82.27standards.
Installationstandards,whereapplicable,are
GypsumAssociationPublicationGA-253,
GA-216andASTMC1280forgypsum
sheathing and soffits.
•NYCMEA312-03-M
•CCMCEvaluationListing#13095-L
•ULEvaluationReportULER3660-1
•OntarioMinisterRulingNo:05-17-141
(13095-R)
Physical Properties High Performance Sheathing
5
Properties
Products-1/2”(12.7mm) Products-Fire-Rated 5/8”(15.9mm) Test
Method/ReferenceGlasRoc®
Sheathing
GlasRoc®
Sheathing Type X
Physical Characteristics:
NominalWidthInches(mm) 48(1219) 48(1219) ASTMC473
StandardLengthFeet(mm) 8*(2438) 8*(2438) ASTMC473
Weight-Lbs/SquareFoot(Kg/m2) 1.9(9.3) 2.4 (11.7) ASTMC473
FaceSurface Polymer/Gypsum Polymer/Gypsum -
Pliability:
BendingRadius- Dry,Lengthwise,Feet(mm)
4 (1219)
6 (1829) -
Strength:
RackingStrength-UltimateValue Lbs/Lin.Ft.-(kN/m) 540(7.88) 654(9.54) ASTME72
ParallelFlexuralStrength-Ibf(N) ≥80 (356) ≥100 (445) ASTMC473
Sag Resistance:
HumidifiedDeflection(Sag)-Inches(mm) 3/32(2.4) 1/16(1.6) ASTMC473
Permeance - perms(ng/Pa•s•m2) 26(1500) 21(1200) ASTME96
Thermal Resistance:
“R” Value - sq.ft.•h•°F/Btu(K•m2/W) 0.45(0.079) 0.57(1.00) ASTMC518
Fire Performance:
FlameSpread/ SmokeDeveloped
0/05/5
0/05/5
ASTME84 CAN/ULC-S102
Combustibility: Noncombustible NoncombustibleASTM E136
CAN/ULC-S114
Dimensional Stability:
Thermal Coefficient of Linear Expansion-in./in./°F(mm/mm/°C)
9.3X10 -6
(16.7 X10 -6)9.3X10 -6
(16.7 X10 -6)ASTME228
Mold Resistance:
MoldResistanceRating** 10** 10** ASTMD3273
* Otherlengthsavailable.AskyourCertainTeedsalesrepresentative.**Nomoldgrowthdetected.Note10ishighestratingpossible.
Water Vapor Transmission:
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com
6
Superior Strength
GlasRoc® Sheathing integrally bonds its
polymer face coating to the moisture
resistant core, resulting in a superior
protective sheathing that will perform in all
climates.
Dimensional Stability
GlasRoc Sheathing resists delamination,
rippling,bucklingandsaggingcaused
by environmental conditions, such as
freeze/thaw,heatandhumidity,anddirect
UV exposure. This technology, with its
embeddedglassmats,makesGlasRoc
Sheathing state-of-the-art, and will provide
aflatanduniformsubstrateforEIFS
applications.
Moisture Resistance
Whenproperlyinstalled,GlasRoc
Sheathingblocksliquidwaterwithout
inhibiting water vapor transmission.
The result is a protective surface that
is extremely resistant to water damage.
Easy to Install
GlasRoc Sheathing is easier to handle
andinstall.Nospecialtoolsare
required. Score it with a standard utility
knife.Installitwithstandardsheathing
fasteners.
Referenced Standards
• ASTMC514:SpecificationforNails
fortheApplicationofGypsumBoard
• ASTMC954:SpecificationforSteelDrill
ScrewsfortheApplicationofGypsum
PanelProductsorMetalPlasterBases
to Steel Studs from
0.33in.(0.84mm)to0.112in.
(2.84mm)inThickness
• ASTMC1002:StandardSpecification
forSteelDrillScrewsfortheApplication
ofGypsumPanelProductsorMetal
PlasterBases
• ASTMC1177:StandardSpecificationfor
GlassMatGypsumSubstrateforUse
as Sheathing
• ASTMC1280:StandardSpecificationfor
ApplicationofGypsumSheathing
• ASTMC1397:PracticeforApplicationof
ClassPBExteriorInsulationandFinish
Systems
• ASTME84(CAN/ULC-S102):
TestMethodforSurfaceBurning
CharacteristicsofBuildingMaterials
• ASTME96:TestMethodsforWater
VaporTransmissionofMaterials
• ASTME119(CAN/ULC-S101):Test
MethodforFireTestsofBuilding
ConstructionandMaterials
Finish Coat
Base Coat
Embedded Reinforced Mesh
EPS Insulation
Bonding Adhesive
Insulation
Metal or wood framing
GlasRoc® Sheathing
As a component of an EIF System, GlasRoc® Sheathing offers:
• Superior water shed and surface
water resistance.
• Excellenttotalwaterabsorption
resistance.
• TwelvemonthresistancetoUV
and environmental exposure.
• Improvedinsulationadhesion
due to integrated board surface.
• Approvedsubstratebythemajor
EIFSmanufacturers.
GlasRoc® SheathingExterior Wall Systems
Exterior Insulation andFinish Systems (EIFS) Applications
7
GlasRoc® Sheathing offers a protective,
smooth, water-resistant application
surface which will withstand water
penetration into the stud cavity, so a
separate weather-resistant barrier may
not be necessary, unless required by
local code. To best prevent air and water
intrusion (when a separate water-resistive
barrier is not required by local codes),
thejointsshouldbetreatedwithexterior
siliconecaulkandglassmeshtape.
Consultwithauthorityhavingjurisdiction,
prior to installation regarding local
requirements.
Installation Recommendations
Wheninstallingabrickorstoneveneerover
GlasRocSheathing,attachthebrick
or masonry ties through the GlasRoc
Sheathing to the structural framing
supports. Consult the manufacturer or local
building code authority for proper spacing
andinstallationofbrickormasonryties.
Referenced Standards
• ASTMC514:SpecificationforNails
fortheApplicationofGypsumBoard
• ASTMC954:SpecificationforSteelDrill
ScrewsfortheApplicationofGypsum
PanelProductsorMetalPlasterBases
toSteelStudsfrom0.33in.(0.84mm)
to0.112in.(2.84mm)inThickness
• ASTMC1002:StandardSpecification
forSteelDrillScrewsfortheApplication
ofGypsumPanelProductsorMetal
PlasterBases
• ASTMC1177:StandardSpecification
forGlassMatGypsumSubstratefor
Use as Sheathing
• ASTMC1280:StandardSpecification
forApplicationofGypsumSheathing
• ASTME84(CAN/ULC-S102):
TestMethodforSurfaceBurning
CharacteristicsofBuildingMaterials
• ASTME96:TestMethodsforWater
VaporTransmissionofMaterials
• ASTME119(CAN/ULC-S101):Test
MethodforFireTestsofBuilding
ConstructionandMaterials
Cavity Wall Applications
GlasRoc® Sheathing
Metal or wood framing
Flashing
Brick Veneer
Wall Tie
Air space
Insulation
Weep Holes
Water-resistive barrier as required by local code
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com
8
GlasRoc® Sheathing’s integral coated
surface with its high surface bond
strength provides an excellent water-
resistant surface for conventional stucco
applications. The treated core adds to
the water-resistive performance of the
product. Conventional stucco systems
rely on the structural soundness of the
sheathing component to which they are
applied. GlasRoc Sheathing offers physical
properties superior to competitive gypsum
sheathingproductsinthemarket.Itis
manufactured to meet or exceed the
physical property requirements outlined in
ASTMC1177.
Installation Recommendation
Inaconventionalstuccosystem,metallath
or other specified self-furring components
should be attached to the framing
members through the GlasRoc Sheathing,
after the appropriate water-resistive barrier
and flashing is installed. Use appropriate
jointtreatmentasrequiredbylocalbuilding
code.Applythestucco,asrecommended
by the manufacturer.
Referenced Standards
• ASTMC514:SpecificationforNailsfor
theApplicationofGypsumBoard
• ASTMC954:SpecificationforSteelDrill
ScrewsfortheApplicationofGypsum
PanelProductsorMetalPlasterBases
toSteelStudsfrom0.33in.(0.84mm)
to0.112in.(2.84mm)inThickness
• ASTMC1002:StandardSpecification
forSteelDrillScrewsfortheApplication
ofGypsumPanelProductsorMetal
PlasterBases
• ASTMC1177:StandardSpecificationfor
GlassMatGypsumSubstrateforUse
as Sheathing
• ASTMC1280:StandardSpecificationfor
ApplicationofGypsumSheathing
• ASTME84(CAN/ULC-S102):
TestMethodforSurfaceBurning
CharacteristicsofBuildingMaterials
• ASTME96:TestMethodsforWater
VaporTransmissionofMaterials
• ASTME119(CAN/ULC-S101):Test
MethodforFireTestsofBuilding
ConstructionandMaterials
Flashing
Conventional Stucco
Metal or wood framing
Insulation
GlasRoc® Sheathing
Metal Lath
Water-resistive Barrier
Conventional Stucco Applications
GlasRoc® SheathingExterior Wall Systems
9
There are numerous exterior claddings
availabletoday,fromshinglestoshakes
to a multitude of siding alternatives.
GlasRoc® Sheathing is an excellent choice
for any of these applications. Simply install
GlasRoc Sheathing and apply the preferred
exterior cladding, per the manufacturer’s
recommendations.Dependingonlocal
buildingcodes,ajointtreatment,water-
resistive barrier, building felt, or building
wrap may be necessary.
Referenced Standards
• ASTMC514:SpecificationforNails
fortheApplicationofGypsumBoard
• ASTMC954:SpecificationforSteelDrill
ScrewsfortheApplicationofGypsum
PanelProductsorMetalPlasterBases
toSteelStudsfrom0.33in.(0.84mm)
to0.112in.(2.84mm)inThickness
• ASTMC1002:StandardSpecification
forSteelDrillScrewsfortheApplication
ofGypsumPanelProductsorMetal
PlasterBases
• ASTMC1177:StandardSpecificationfor
GlassMatGypsumSubstrateforUse
as Sheathing
• ASTMC1280:StandardSpecificationfor
ApplicationofGypsumSheathing
• ASTME84(CAN/ULC-S102):
TestMethodforSurfaceBurning
CharacteristicsofBuildingMaterials
• ASTME96:TestMethodsforWater
VaporTransmissionofMaterials
• ASTME119(CAN/ULC-S101):Test
MethodforFireTestsofBuilding
ConstructionandMaterials
Exterior Cladding
Metal or Vinyl Siding
Fiber-Cement Siding
Wood Siding
GlasRoc® Sheathing
Insulation
Metal or wood framing
Shingle orShake Siding
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com
Water-resistive barrier as required by local code
10
Exterior Archways, Exterior Concave & Convex Surfaces
2” (50 mm) Glass Mesh Tape
Finish Coat
Base Coat
GlasRoc® Sheathing
Refer to finish system
manufacturer for glass mesh
reinforcement requirements.
GlasRoc® Sheathing is engineered for
use in curved exterior gypsum board
applications. There is no need to score or
moisten the board to bend it. To prevent
flat areas in the curved surface, framing
should be positioned at a maximum
spacingof6”(150mm).
ConsulttheGypsumAssociationdocument
GA-226forframingrecommendations.
Application to Archways
GlasRoc Sheathing can be installed in an
archway or on a concave or convex surface
by applying pressure onto the board to fit
the radius and then holding it firmly in place
while fastening it to the framing members.
To best seat the product in tight radius
applications, temporarily install a stop at
one end of the framed radius to serve as
arestraintsupport.Installtheproductwith
coated side out with one of the width ends
placed flush against the temporary stop
and secure with fasteners, one framing
member at a time. Repeat until the product
has been secured to all framing members.
Fastenersshouldbespacednogreater
than8”(200mm)apart.
Referenced Standards
• ASTMC954:SpecificationforSteel
DrillScrewsfortheApplicationof
GypsumPanelProductsorMetal
PlasterBasestoSteelStudsfrom
0.33in.(0.84mm)to0.112in.
(2.84mm)inThickness
• ASTMC1002:StandardSpecification
forSteelDrillScrewsfortheApplication
ofGypsumPanelProductsorMetal
PlasterBases
• ASTMC1177:StandardSpecificationfor
GlassMatGypsumSubstrateforUseas
Sheathing
• ASTMC1280:StandardSpecificationfor
ApplicationofGypsumSheathing
• ASTMC1397:PracticeforApplicationof
ClassPBExteriorInsulationandFinish
Systems
• ASTME84(CAN/ULC-S102):
TestMethodforSurfaceBurning
CharacteristicsofBuildingMaterials
• ASTME96:TestMethodsforWater
VaporTransmissionofMaterials
SheathingBoard Thickness
Tested-Bent Lengthwise Radii
1/2”(12.7mm) GlasRoc® Sheathing 4’-(1219mm)
5/8”(15.9mm) GlasRoc® Sheathing Type X 6’-(1829mm)
Recommended Lengthwise Bending Radii
GlasRoc® SheathingExterior Designs / Arches & Soffits
11
Finish Coat
GlasRoc® Sheathing is a superior
product for a flat ceiling entryway,
exterior ceiling, or a soffit assembly,
due to its ability to resist the deteriorating
effects of moisture and humidity.
The industry defines the amount of
permissiblesagginginahorizontal
application as humidified deflection.
ThereareseveralASTMStandard
Specifications that define a maximum
allowable humidified deflection including
ASTMC1396andASTMC1177.Of these,
ASTMC1177hasthemoststringent
requirements.NotehowGlasRoc®
Sheathing performs.
Installation Recommendations
for Exterior Ceilings & Soffits
Use GlasRoc Sheathing in exterior ceiling
and soffit systems where weather-resistant
performance is critical, including but not
limitedto,ceilings/soffitswithfinished
jointsandceilings/soffitswithoutinsulation.
Installtheproductlikeastandard
gypsumexteriorsoffitboard.Fastenthe
product to the framing members using the
recommendationsspecifiedinGA-216
andASTMC840.Finishingis
accomplishedwitheither;1)Direct-
AppliedExteriorFinishSystem(DEFS)per
the manufacturer’s specifications, or 2)
applying nominal 2” glass mesh drywall
tapeand90minutesetting-typejoint
compoundontheboardjoints,skim-
coating the entire surface of the ceiling
soffit with a setting-type compound and
priming and painting with exterior grade
primer and paint per the manufacturer’s
recommendations.
Referenced Standards
• ASTMC514:SpecificationforNails
fortheApplicationofGypsumBoard
• ASTMC931:StandardSpecification
forExteriorGypsumSoffitBoard
• ASTMC840:StandardSpecificationfor
ApplicationandFinishingofGypsumBoard
• ASTMC954:SpecificationforSteelDrill
ScrewsfortheApplicationofGypsum
PanelProductsorMetalPlasterBases
toSteelStudsfrom0.33in.(0.84mm)
to0.112in.(2.84mm)inThickness
• ASTMC1002:StandardSpecification
forSteelDrillScrewsfortheApplication
ofGypsumPanelProductsorMetal
PlasterBases
• ASTMC1177:StandardSpecification
forGlassMatGypsumSubstratefor
Use as Sheathing
• ASTMC1397:PracticeforApplication
ofClassPBExteriorInsulationand
FinishSystems
• ASTME84(CAN/ULC-S102):
TestMethodforSurfaceBurning
CharacteristicsofBuildingMaterials
• ASTME96:TestMethodsforWater
VaporTransmissionofMaterials
Properties1/2”(12.7mm)
GlasRoc Sheathing
1/2”(12.7mm) Gypsum Soffit
Board
5/8”(15.9mm) GlasRoc
Sheathing Type X
5/8”(15.9mm) Gypsum Type X
SoffitBoard
ASTM TESTMETHOD
Surface Polymer Paper Polymer Paper
Humidified Deflection(Sag) 3/32”(2.4mm) 7/8”(22mm) 1/16”(1.6mm) 1/2”(13mm) C473
GlasRoc® Sheathing in Exterior Ceiling & Soffit Applications
Exterior Soffit
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com
GlasRoc® Sheathing
Base Coat with Embedded Reinforced Mat
Flat Ceiling Entryways, Exterior Ceilings & Soffits
Water Absorption <10% 40% <10% 40% C473
12
GlasRoc® Sheathing Type XExterior Wall / Fire-Rated Systems
Reference: UL Design U465
24” (600 mm)
5/8” (15.9 mm)GlasRoc® Sheathing Type X
3-5/8” (92 mm) Steel Studs
3-5/8” (92 mm) Steel Track
1-Hour Fire-Resistance Rating
Cavity thickness ..... 3-5/8” (92 mm)
Wall thickness ......... 4-7/8” (124 mm)
Weight ..................... 6 psf (29 kg/m2)
Steel Stud System
5/8” (15.9 mm) CertainTeed® Type X gypsum board
3-1/2” (89 mm) Glass Fiber or Mineral Wool Insulation
(optional)
5/8"(15.9mm)panelswithsquareortaperededges,appliedverticallyorhorizontally.
Verticaljointscenteredoverstudsandstaggeredonestudcavityonoppositesidesof
stud.Horizontaledgejointsandhorizontalbuttjointsonoppositesidesofstudsneed
notbestaggeredorbackedbysteelframing.Panelsattachedtosteelstudsandfloor
runner with 1"(25mm)TypeSsteelscrewsspaced8"(200mm)o.c.whenapplied
horizontally,or8"(200mm)o.c.alongverticalandbottomedgesand12"(300mm)
inthefieldwhenpanelsareappliedvertically.Whenusedinwidthsotherthan
48"(1200mm),panelsaretobeinstalledhorizontally.
13
5/8” (15.9 mm)GlasRoc ® Sheathing Type X
3-1/2” (89 mm) Glass Fiber or Mineral Wool Insulation
2-1/2” (64 mm) Steel Studs
2-1/2” (64 mm) Steel Track
5/8” (15.9 mm) CertainTeed®
Type X gypsum board
24” (600 mm)
Steel Stud System
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com
2-Hour Fire-Resistance Rating
Cavity thickness ..... 2-1/2” (64 mm)
Wall thickness ......... 5” (127 mm)
Weight ..................... 11 psf (54 kg/m2)
Interior
Installinsulationbetweenstuds.Applya
baselayerof5/8”(15.9mm)CertainTeed®
Type X gypsum board vertically to interior
sidewith1”(25mm)TypeSsteelscrews
spaced16”(400mm)o.c.alongedgesand
inthefield.Jointsmustbeoffsetfrom
jointsontheoppositeside.
Applyafacelayerof5/8”(15.9mm)
CertainTeed Type X gypsum board vertically
overbaselayerwith1-5/8”(41mm)
Type S steel screws. Space fasteners 16”
(400mm)o.c.alongedgesand12”
(300mm)o.c.alongfloorandceiling
runners.Jointsmustbeoffsetfromjointsin
theunderlyinglayer.Tapeandfinishjoints.
Reference: UL Design U411
Exterior
Applyabaselayerof5/8”(15.9mm)
GlasRoc® Sheathing Type X vertically to
exteriorsidewith1”(25mm)TypeSsteel
screwsspaced16”(400mm)o.c.along
edgesandinthefield.Jointsmustbe
offsetfromjointsontheoppositeside.
Applyafacelayerof5/8”(15.9mm)
GlasRoc Sheathing Type X vertically over
baselayerwith1-5/8”(41mm)TypeS
steelscrews.Spacefasteners16”(400
mm) o.c. along edges and field and 12”
(300mm)o.c.alongthefloorandceiling
runners.Jointsmustbeoffsetfromjointsin
the underlying layer.
14
1-Hour Fire-Resistance Rating
Cavity thickness ..... 3-1/2” (89 mm)
Wall thickness ......... 4-3/4” (121 mm)
Weight ..................... 6 psf (29 kg/m2)
Interior
Installinsulationbetweenstuds.Applyone
layerof5/8”(15.9mm)CertainTeed® Type
X gypsum board vertically to interior side
with1”(25mm)TypeS-12steelscrews
spaced12”(300mm)o.c.alongedges
andinthefield.Jointsmustbeoffsetfrom
jointsontheoppositeside.Tapeandfinish
joints.
24” (600 mm)
5/8” (15.9 mm)GlasRoc® Sheathing Type X
3-1/2” (89 mm) Glass Fiber orMineral Wool Insulation
3-1/2” (89 mm) Steel Studs
3-1/2” (89 mm) Steel Track
Reference: UL Design U425(Load-Bearing)
Steel Stud System
5/8” (15.9 mm) CertainTeed®
Type X gypsum board
GlasRoc® Sheathing Type X Exterior Wall / Fire-Rated Systems
Exterior
Applyonelayerof5/8”(15.9mm)
GlasRoc® Sheathing Type X vertically to
exteriorsidewith1”(25mm)screws
spaced12”(300mm)o.c.alongedges
andinthefield.Jointsmustbeoffset
fromjointsontheoppositeside.
15
2-Hour Fire-Resistance Rating
Cavity thickness ..... 3-1/2” (89 mm)
Wall thickness ......... 6” (150 mm)
Weight ..................... 11 psf (54 kg/m2)
Interior
Installinsulationbetweenstuds.Applyone
layerof5/8”(15.9mm)CertainTeed® Type
Xgypsumboardverticallywith1”(25mm)
Type S-12 steel screws spaced 12”
(300mm)o.c.alongedgesandinthefield.
Jointsmustbeoffsetfromjointsonthe
opposite side.
Applyafacelayerof5/8”(15.9mm)
CertainTeed Type X gypsum board
verticallywith1-5/8”(41mm)TypeS-12
steelscrewsspaced12”(300mm)o.c.
alongedgesandinthefield.Jointsmust
beoffsetfromjointsintheunderlyinglayer.
Tapeandfinishjoints.
Reference: UL Design U425(Load-Bearing 80% of Design)
5/8” (15.9 mm) GlasRoc® Sheathing Type X
3-1/2” (89 mm) Glass Fiber orMineral Wool Insulation
3-1/2” (89 mm) Steel Studs
3-1/2” (89 mm) Steel Track
5/8” (15.9 mm) CertainTeed®
Type X gypsum board
24” (600 mm)
Steel Stud System
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com
Exterior
Applyabaselayerof5/8”(15.9mm)
GlasRoc® Sheathing Type X vertically with
1”(25mm)TypeS-12steelscrewsspaced
12”(300mm)o.c.alongedges
andinthefield.Jointsmustbeoffset
fromjointsontheoppositeside.
Applyafacelayerof5/8”(15.9mm)
GlasRoc Sheathing Type X vertically with
1-5/8”(41mm)TypeS-12steelscrews
spaced12”(300mm)o.c.alongedges
andinthefield.Jointsmustbeoffsetfrom
jointsintheunderlyinglayer.
Additional UL Design Listings for
Steel Stud Systems:
U017,U405,U417,U418,U420,U421,
U422,U434,U442,U445,U450,U460,
U466,U467,U473,U475,U485,U487,
U494,U501,U502,U504,U505,U506,
U510,U512,U615,U617,U622,U623,
U626,V417,V419,V469andV486.
Additional ULC Design Listings for
Steel Stud Systems:
W412,W447,W449,W456andW465.
Additional GA-600 Listings for Steel
Stud Systems:
GAFileNo.WP7210,WP8006,WP8203,
WP9020,WP9200andWP9205.
16
5/8” (15.9 mm)GlasRoc ® Sheathing Type X
2” x 4” (38 mm x 89 mm)Wood Studs
2” x 4” (38 mm x 89 mm) Wood Plates
24” (600 mm)
5/8” (15.9 mm) CertainTeed® Type X gypsum board
3-1/2” (89 mm) Glass Fiber orMineral Wool Insulation
Reference: UL Design U3091-Hour Fire-Resistance Rating
Cavity thickness ..... 3-1/2” (89 mm)
Wall thickness ......... 4-3/4” (121 mm)
Weight ..................... 7 psf (34 kg/m2)
Interior
Installinsulationbetweenstuds.Applyone
layerof5/8”(15.9mm)CertainTeedType
Xgypsumboardwith1-7/8”(48mm)nails
spaced7”(175mm)o.c.alongedgesand
inthefield.Jointsmustbeoffsetfrom
jointsontheoppositeside.Tapeand
finishjoints.
Exterior
Applyonelayerof5/8”(15.9mm)GlasRoc
SheathingTypeXwith1-7/8”(48mm)
nailsspaced7”(175mm)o.c.alongedges
andinthefield.Jointsmustbeoffsetfrom
jointsontheoppositeside.
Wood Stud System
5/8” (15.9 mm)GlasRoc ® Sheathing
Type X
3-1/2” (89 mm) Glass Fiber or Mineral Wool
Insulation
2” x 4” (38 mm x 89 mm)
Wood Studs
2” x 4” (38 mm x 89 mm) Wood Plates
16”(400 mm)
5/8” (15.9 mm) CertainTeed®
Type X gypsum board
Reference: UL Design U3051-Hour Fire-Resistance Rating
Cavity thickness ..... 3-1/2” (89 mm)
Wall thickness ......... 4-3/4” (121 mm)
Weight ..................... 7 psf (34 kg/m2)
Interior
Installinsulationbetweenstuds.
Applyonelayerof5/8”(15.9mm)
CertainTeed® Type X gypsum board
vertically or horizontallywith1-7/8”
(48mm)nailsspaced7”(175mm)o.c.
alongedgesandinthefield.Jointsmust
be offset from jointsontheoppositeside.
Tape andfinishjoints.
Exterior
Applyonelayerof5/8”(15.9mm)GlasRoc®
SheathingTypeXverticallyorhorizontally
with1-7/8”(48mm)nailsspaced7”(175mm)
o.c.alongedgesandinthefield.Jointsmust
beoffsetfromjointsontheoppositeside.
Wood Stud System (Load-Bearing)
GlasRoc® Sheathing Type XExterior Wall / Fire-Rated Systems
17
2-Hour Fire-Resistance Rating
Cavity thickness ..... 3-1/2” (89 mm)
Wall thickness ......... 6” (152 mm)
Weight ..................... 12 psf (59 kg/m2)
Interior
Applyabaselayerof5/8”(15.9mm)
CertainTeed® Type X gypsum board
verticallyorhorizontallywith1-7/8”(48mm)
nailsspaced6”(150mm)o.c.alongedges
andinthefield.Jointsmustbeoffsetfrom
jointsontheoppositeside.Verticaljoints
must be located over framing members.
Applyafacelayerof5/8”(15.9mm)
CertainTeed Type X gypsum board vertically
orhorizontallywith2-3/8”(60mm)nails
spaced8”(200mm)o.c.alongedgesandin
thefield.Jointsmustbeoffsetfromjointsin
theunderlyinglayer.Tapeandfinishjoints.
Exterior
Applyabaselayerof5/8”(15.9mm)
GlasRoc® Sheathing Type X vertically
orhorizontallywith1-7/8”(48mm)nails
spaced6”(150mm)o.c.alongedgesand
inthefield.Jointsmustbeoffsetfromjoints
ontheoppositeside.Verticaljointsmustbe
located over framing members.
Applyafacelayerof5/8”(15.9mm)
GlasRoc Sheathing Type X vertically or
horizontallywith2-3/8”(60mm)nails
spaced8”(200mm)o.c.alongedges
andinthefield.Jointsmustbeoffset
fromjointsintheunderlyinglayer.
Tapeandfinishjoints.
Wood Stud System (Load-Bearing)
5/8” (15.9 mm)GlasRoc®
Sheathing Type X
2” x 4” (38 mm x 89 mm)Wood Studs
2” x 4” (38 mm x 89 mm) Wood Plates
5/8” (15.9 mm) CertainTeed® Type X gypsum board
16” (400 mm)
Reference: UL Design U301
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com
Additional UL Design Listings for Wood Stud Systems:
U326,U329,U330,U332,U337,U338,U339,U341,U342,U344,
U354,U355,U356,U357,U358,U360,U374,U376,U391andV314.
Additional GA-600 Listings for Wood Stud Systems:
GAFileNo.WP8105,WP8109,WP8111,WP8126,WP8130,
WP8410,WP8415,WP8416andWP8420.
18
GlasRoc® Sheathing Type XExterior Wall / Fire-Rated Systems
Additional UL Design Listings for Wood Stud Systems:
U326,U329,U330,U332,U337,U338,U339,U341,U342,U344,
U354,U355,U356,U357,U358,U360,U374,U376,U391andV434.
Additional ULC Design Listings for Wood Stud Systems:
W310andW313.
Additional GA-600 Listings for Wood Stud Systems:
GAFileNo.WP8105,WP8109,WP8111,WP8126,WP8130,
WP8410,WP8415,WP8416andWP8420.
2-Hour Fire-Resistance Rating
Cavity thickness ..... 3-1/2” (89 mm)
Wall thickness ......... 10” (254 mm)
Interior
Installinsulationbetweenstuds.
Applyabaselayerof5/8”(15.9mm)
CertainTeed® Type X gypsum board
verticallyorhorizontallywith1-7/8”
(48mm)nailsspaced8”(200mm)o.c.
Verticaljointsmustbelocatedover
framing members.
Applyafacelayerof5/8”(15.9mm)
CertainTeed Type X gypsum board
verticallyorhorizontallytotheinterior
sidewith2-3/8”(60mm)nailsspaced
8”(200mm)o.c.Jointsmustbeoffset
fromjointsintheunderlyinglayer.Tape
andfinishjoints.
Exterior
Applyonelayerof1/2”(12.7mm)
GlasRoc® Sheathinghorizontallyto
theexteriorsidewith1-3/4” (44 mm)
roofing nails spaced 6” (150mm) o.c.
Verticaljointsmustbelocatedover
framing members and staggered.
Wood Stud System
3-1/2” (89 mm)Glass Fiber orMineral Wool
Insulation
Clay Face Bricks
1/2” (12.7 mm) GlasRoc® Sheathing
2” x 4” (38 mm x 89 mm)Wood Studs
2” x 4” (38 mm x 89 mm) Wood Plates
5/8” (15.9 mm)CertainTeed® Type X
gypsum board
16”(400 mm)
Air Space
Reference: UL Design U302
19
GlasRoc® Sheathing Type XFire-Rated / Floor & Ceiling Systems
1-Hour Fire-Resistance Rating
Flooring
2”(51mm)3000psi(21MPa)
compressive strength normal weight
concretepouredoversteeldeck.
Ceiling
Fastensteelfurringchannelstojoists
24”(600mm)o.c.withdoubletiewires,
except12”(300mm)o.c.atendjoints.
SeeDetailA.Adjoininglengthsofchannels
lapped2’-6”(750mm).
Applyonelayerof5/8”(15.9mm)GlasRoc®
Sheathing Type X with the long dimension
perpendicular to the furring channels with
1”(25mm)TypeSsteelscrewsspaced
12”(300mm)o.c.Locatescrews1/2”
(12.7 mm) from edges and ends of board.
Reference: UL Design L5011-Hour Fire-Resistance Rating
Thickness ........... 11” (279 mm)
Weight ................ 13.5 psf (66 kg/m2)
Framing
Setjoists16”(400mm)o.c.Cross-brace
and firestop, as required.
Flooring
Applysubflooringwithfacegrain
perpendiculartojoistwithjointsstaggered.
Finishedflooringwoodstructuralgrade
T&GDouglasFirplywoodwithface
grainperpendiculartojoistswithjoints
staggered.
Applyonelayerof5/8”(15.9mm)GlasRoc
Sheathing Type X with the long dimension
perpendiculartojoistswith1-7/8”(48mm)
nails spaced 6” (150mm) o.c.
Finishandtapejoints.
Detail A
24”(600 mm)
3/8” (9.5mm)
5/8” (15.9 mm) GlasRoc® Sheathing Type X
Steel Joist
Steel Furring Channel
24” (600 mm)
Reference: UL Design G501
5/8” (15.9 mm) GlasRoc® Sheathing Type X
Firestopped
Subflooring2” x 10” (38 mm x 235 mm)Wood Joists
1” x 3” (19 mm x 64 mm)Cross Bridging
16”(400 mm)
Additional UL Design Listings for Floor-Ceiling Systems
SteelJoistFloor-Ceiling:G520andG531.WoodJoistFloor-Ceiling:L508,L591.
Additional ULC Design Listings for Floor-Ceiling Systems
M500.
Additional GA-600 Listings for Floor-Ceiling and Roof-Ceiling Systems
SteelJoistFloor-Ceiling:GAFileNo.FC1130,FC2116,FC2120,FC4490andFC4750.
WoodJoistFloor/Roof-Ceiling:GAFileNo.FC5310,FC5406,FC5407,FC5408,FC5420,
FC5600,FC5725,FC5750,FC5751,RC2601,RC2602,RC2750andRC2751.
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com
20
GlasRoc® Sheathing Type XFire-Rated / Beam & Column Systems
2-Hour Fire-Resistance Rating
STEEL BEAM
Attachchannelstosteeldeckwith1/2”
(12.7 mm) Phillips pan head screws spaced
12”(300mm)o.c.Fabricatechannel
bracketsbycuttingnotchesinchannelat
location of corners and fold channel to form
U-bracketoftherequiredsize.Aminimum
1/2”(12.7mm)clearanceisrequiredat
sides and bottom of the beam.
Attachchanneltoangle24”(600mm)
o.c.,with1/2”(12.7mm)Phillipspanhead
screws. Place steel corner angle at lower
cornersofU-brackets.Applyabaselayer
of5/8”(15.9mm)GlasRoc® Sheathing Type
Xwith1-1/4”(32mm)Phillipspanhead
screwsspaced16”(400mm)o.c.Apply
afacelayerof5/8” (15.9mm) GlasRoc
SheathingTypeXwith1-3/4”(44mm)
Phillipspanheadscrewsspaced8”(200
mm)o.c.Jointsmustbeoffsetfromthe
jointsintheunderlayinglayer.Attachcorner
beadtocorners.Tapeandfinishjoints.
2-Hour Fire-Resistance Rating
STEEL COLUMNS
Position steel studs at column corners.
Steel studstobe1/2”(12.7mm)less
than assembly height.
Applyabaselayerof5/8”(15.9mm)
GlasRoc Sheathing Type X vertically with
1”(25mm)Phillipspanheadscrews
spaced24”(600mm)o.c.Applyaface
layerof5/8”(15.9mm)GlasRoc Sheathing
Type X vertically around the perimeter with
1-3/4”(44mm)Phillipspanheadscrews
spaced12”(300mm)o.c.Applycorner
beadwith1-5/8”(41mm)screwsspaced
12”(300mm)o.c.Tapeandfinishjoints.
5/8” (15.9 mm) GlasRoc® Sheathing Type X
Steel Beam Minimum(W8 x 24) W200 x 36 Steel Corner Bead
Steel Angle
Steel Channel
Steel Floor Unit
Concrete Slab
Finishing
Reference: UL Design N502
Reference: UL Design X528
Diagram A: WF
Additional UL Design Listings for Beam & Column Systems
BeamProtection:N501,N502andN505.ColumnProtection:X508,X516,
X517,X525andX526.
Additional GA-600 Listings for Beam & Column Systems
BeamProtection:GAFileNo.BM2120andBM2130.ColumnProtection:
GAFileNo.CM1850,CM1851,CM2017,CM2020,CM2120,CM3115,
CM3116,CM3120,CM4110andCM4600.
5/8” (15.9 mm) GlasRoc®
Sheathing Type X
Steel Corner Bead
Finishing
1-5/8” (41 mm) Steel Stud
21
Wall Framing
Whererequired,diagonallet-inbracingis
recommended for corners.
•1/2”(12.7mm)GlasRoc Sheathing should
be fastened to wood or steel framing
spaced no more than a maximum of 24”
(600mm)o.c.
•5/8” (15.9mm)GlasRoc Sheathing Type
X should be fastened to wood or steel
framing spaced no more than a maximum
of24”(600mm)o.c.
Ceiling and Soffit Framing
•1/2”(12.7mm)GlasRoc Sheathing should
be fastened to wood or steel framing
spaced no more than a maximum of 16”
(400mm)o.c.forparalleltostudframing
andmaximumof24”(600mm)o.c.for
perpendicular to stud framing.
•5/8”(15.9mm)GlasRoc Sheathing
Type X should be fastened to framing
spaced no more than a maximum of 24”
(600mm)o.c.parallelorperpendicular
to wood or steel framing.
GlasRoc® SheathingFastening Patterns
Framing & Joint Treatments
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com
Fastening Guidelines
•FastenGlasRoc® Sheathing using only recommended nails or screws.
•AlwaysapplyGlasRoc Sheathing to a flat and even framing surface.
•Drivefastenerstoapointevenwithorslightlybelow[nogreaterthan1/32”(0.8mm)] the surface of GlasRoc Sheathing, without penetrating glass mat.
•Locateperimeterfastenersaminimumof3/8”(10mm)fromedgesandendswithamaximumspacingof8”(200mm)o.c.
• Forshearresistanceapplications, space perimeter fasteners a maximum 4”(100mm)o.c.
•Spacefastenersinthefieldofthe boardamaximumof8”(200mm)o.c.
Limitations
•Donotusestaplesoradhesivestofasten GlasRoc Sheathing to framing members.
•DonotattachGlasRoc Sheathing to framing surfaces with a plane variance greaterthan1/8”(3mm).
•Donotoverdrivefasteners.Becarefulnottobreaktheprotectivesurfacecoating, fracture the underlying core, or penetrate the glass mat.
•GlasRoc Sheathing is not recommended or intended for use as a fastening base.
•Notrecommendedforapplicationswhere continuous exposure temperaturesexceed125°F(52° C).
Fasteningpatternsandotherdetailed
information for the recommended
handling, storage, and application of
gypsum sheathing can be found below
andinthefollowingGAinstallation
specificationguides:GA-253Application
ofGypsumSheathing,GA-254Fire
ResistantGypsumSheathing,GA-216
ApplicationandFinishingofGypsum
Board,GA-226ApplicationofGypsum
BoardtoCurvedSurfaces.
FramingType Fastener Description
1/2”(12.7mm) GlasRoc® Sheathing
5/8”(15.9mm) GlasRoc® Sheathing Type X
WoodHotdip11gage,7/16”(11mm)head,
galvanizednail1-1/2”(38mm) 1-3/4”(44mm)
WoodHotdip12gage,7/16”(11mm)head,
galvanizednail1-1/2”(38mm) 1-3/4”(44mm)
Wood/FurringBuglehead(TypeW),corrosionresistant
screws with coarse threads1-1/4”(32mm)
1-1/4”(32mm)to 1-5/8”(41mm)
Steel/FurringBuglehead(TypeS),corrosionresistant
screws with fine threads1”(25mm) 1-1/4”(32mm)
Light SteelBuglehead(TypeS),corrosionresistant
screws with fine threads1”(25mm) 1-1/4”(32mm)
Light SteelBuglehead(TypeS,TypeS-12)
steel drill screws1-1/4”(32mm)
1-1/4”(32mm)to 1-5/8”(41mm)
Heavy/LightSteelBuglehead(TypeS-12,TypeS)
steel drill tip screws1-1/4”(32mm)
1-1/4”(32mm)to 1-5/8”(41mm)
HeavySteelBuglehead(TypeS-12)drilltip,finethread,rust
resistant gypsum board screws1”(25mm)
1-1/4”(32mm)to 1-5/8”(41mm)
Recommendations for Fasteners Recommended Fastener Length for Board Thickness
22
What is Covered?
5 Year Limited Warranty
Against Defects
CertainTeed Gypsum (“CertainTeed”)
warrants that its GlasRoc® Sheathing
(“Product”) shall be free from defects in
themanufactureofmaterialsthatmakeit
unsuitable for its intended use, and that
it meets or exceeds the manufacturing
requirements and specifications of
ASTMC1177.
12 Month Warranty Against Exposure
CertainTeed further warrants for up to
twelve (12) months that the Product will
withstand exposure to normal weather
conditions, e.g., UV, rain, wind, ice and
snow, so long as the Product is stored
and installed according to CertainTeed’s
instructions contained in Sections 1.6 and
3.1oftheGlasRocSheathingArchitectural
Specifications.
The5YearLimitedWarrantyandthe12
MonthLimitedWarrantyextendtodealers
who sell this Product, contractors who
install this Product, and the original owner
of the building within the warranty period.
Neitherthe5YearLimitedWarrantynor
the12MonthLimitedWarrantymaybe
assigned or transferred.
How Long Does Coverage Last?
The5YearLimitedWarrantyshall
commence with the date of purchase
by the installing contractor or product
applicator,andcontinueforfive(5)years.
The12MonthLimitedWarrantyshall
commence on the date of installation of
the Product and continue for twelve (12)
months.
What is Not Covered?
CertainTeed shall not be responsible for any
lossresultingfromanyofthefollowing:
•Installationpracticesnotinaccordance
with CertainTeed’s published
recommendation and specifications.
•Improperdesignorinstallationofany
component or portion of the structure.
•DamagetoGlasRocSheathingcausedby
anEIFSsystemnotinstalledinaccordance
with the application instructions of the
EIFSmanufacturer,thearchitectural
specificationsorASTMC1397,“Standard
PracticeforApplicationofClassPB
ExteriorInsulationandFinishSystems”.
•Moistureintrusiondefectsincludinginsect,
fungus, and mold infestation resulting from
the use of other manufacturers’ products.
•Failureoftheownertomaintainthe
building with reasonable care.
•UseofGlasRocSheathingasasubstrate
for any exterior or coatings that are
directly applied to the panel surface
(excluding soffit areas).
•Excludesdamagecausedbyimproper
handling or storage, immersion in water,
floods,fires,hailstorms,earthquakes,
high winds, hurricanes, acts of nature,
fallingobjects,settlingofthebuilding,
movement of the framing members,
failure or distortion in the walls or
foundation of the structure.
•CertainTeedisnotresponsibleforthe
performance of the exterior system
applied over GlasRoc Sheathing including
but not limited to coatings, cladding and
wall coverings.
Effect of State/Provincial Law
THISWARRANTYSTATESTHEFULLEXTENT
OFCERTAINTEED’SRESPONSIBILITY
FORDEFECTSINTHEPRODUCT.
ALLOTHERREPRESENTATIONSAND
WARRANTIESEITHEREXPRESSEDOR
IMPLIED,INCLUDINGWARRANTIESOF
FITNESSFORAPARTICULARPURPOSE
ORMERCHANTABILITY,AREHEREBY
DISCLAIMED.
INNOEVENTSHALLCERTAINTEEDBE
LIABLEFORLOSSOFPROFITSORANY
CONSEQUENTIAL,SPECIAL,INCIDENTAL,
INDIRECTORPUNITIVEDAMAGES,
WHETHERBASEDUPONBREACHOF
WARRANTYNEGLIGENCE,STRICTLIABILITY,
TORT,BREACHOFCONTRACT,ORANY
OTHERLEGALTHEORY.
Some states do not allow the exclusion
or limitation of warranties or do not allow
the exclusion or limitation of incidental or
consequential damages, so the above
disclaimers may not apply to you.
What will CertainTeed do?
CertainTeed will, at its option, provide
replacement Product or a refund up to
double the purchase price.
How To Handle Claims?
Submitallclaimsinwritingwithin30days
of the defect discovery, including a brief
description of the damaged area, with a
copy of the dated sales receipt, invoice and
evidenceofinstallationdate,to:
CertainTeed Gypsum
4300 W. Cypress St., Ste 500
Tampa, FL 33607
USA
Attn: Marketing Manager, Commercial
GlasRoc Sheathing
To effect this sole and exclusive remedy,
the claim must be submitted in writing prior
to the end of the warranty period.
THISSHALLCONSTITUTETHETOTAL
LIABILITYOFCERTAINTEEDANDTHE
EXCLUSIVEREMEDYOFCUSTOMER.
THEREARENOOTHERWARRANTIES,
EXPRESSORIMPLIED,INCLUDINGANY
WARRANTYOFMERCHANTABILITYOR
FITNESSFORAPARTICULARPURPOSE.
LIABILITYISLIMITEDTOTHEABOVEAND
CERTAINTEEDSHALLINNOEVENTBE
LIABLEFORLABORCHARGES,INCLUDING
BUTNOTLIMITEDTO,LABORCHARGES
INCONNECTIONWITHREMOVALOR
REPLACEMENT,NORFORINCIDENTALOR
CONSEQUENTIALDAMAGES.
NorepresentativeofCertainTeedhas
theauthoritytomakeanyrepresentation
or promise with respect to this limited
warranty or otherwise amend, restate, or
supplement this limited warranty.
This warranty applies to GlasRoc Sheathing
soldonorafterJanuary1,2008,intheU.S.
and Canada.
GlasRoc® Sheathing5 Year Limited Warranty
23
SAFETY:
Formoreinformation,consulttheMaterialSafetyDataSheetbycontactingCertainTeedat1-800-233-8990 oremail:building.solutions@certainteed.com.Foranelectroniccopyofthisspecification,pleasevisit: www.certainteed.com
Section 09253 / 06 16 00 - Sheathing
Part 1-General1.1 RELATED DOCUMENTS
A. Drawingsandgeneralprovisionsofthe Contract, including General and Supplementary
ConditionsandDivision1.SpecificationSections, apply to this Section.
1.2 SUMMARY
A. ThisSectionincludesthefollowing:
1.EmbeddedGlassReinforcedGypsum (EGRG™)SheathingBoard.
2. Sheathingjoint-and-penetrationtreatment.
1.3 DEFINITIONS
A. GypsumBoardConstructionTerminologyStandard:RefertoASTMC11fordefinitionsofterms for gypsum sheathing board construction not defined in this Section or in other referenced standards.
1.4 SUBMITTALS
A. SubmitinaccordancewithSection01330.
B. ProductData:Foreachtypeofproductindicated.
C. InformationalSubmittals:Submitmanufacturer’s instructions, special procedures, and perimeter conditions requiring special attention.
1.5 QUALITY ASSURANCE
A. Fire-Test-ResponseCharacteristics:Forassemblies with fire-resistance ratings, provide materials and construction identical to those of assembliestestedforfireresistanceperASTME119(UL263,CAN/ULC-S101)byatestingandinspecting agency acceptable to authorities having jurisdiction.
1.Fire-ResistanceRatings:IndicatedbydesigndesignationsfromULIandULC“FireResistanceDirectory”andProductsCertifiedfor Canada.
B. SingleSourceResponsibility:Exceptwherespecified otherwise, obtain gypsum board
products,jointtreatment,andaccessoriesfrom single manufacturer or from manufacturers recommended by prime manufacturer of gypsum board products.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Store materials protected against damage from weather, direct sunlight, surface contamination, construction traffic, or other causes.StackCertainTeedGlasRoc® Sheathing flat on leveled supports off the ground, under cover, and fully protected from weather.
1. Store and support CertainTeed GlasRoc Sheathingboardinflatstackstopreventsagging.
2.Protectmaterialstokeepthemdry.
3.Protectgypsumboardpanelstopreventdamage to edges, ends, and surfaces.
1.7 COORDINATION
A. CertainTeedGlasRocSheathing:
1.EGRG™SheathingBoard:Intendedforup to 12 (twelve) months of exposure following installation.
1.8 WARRANTY
A. Manufacturer’sstandardwarrantyforproductexposed to weather without failure, when installed in accordance with manufacturer’s requirements, for period of not less than 12 months.
Part 2-Product
2.1 GYPSUM SHEATHING
A. EmbeddedglassmatgypsumsheathingmeetingtherequirementsofASTMC1177.
1.CertainTeedGypsum,Inc.
a.BasisofDesign:“GlasRocSheathing”withEGRGTM technology
b.Substitutions:SubmitinaccordancewithSection01600.
2. TypeandThickness:TypeX,5/8inch(15.9mm) thickwhereindicatedandasotherwiserequired to meet fire rating for specific element.[1/2inch(12.7mm)elsewhere.]
a.Flamespread:ASTME84:0; CAN/ULC-S102:5
b.Smokedeveloped:ASTME84:0; CAN/ULC-S102:5
3.Size:48bynotlessthan96inches(1219bynotlessthan2438mm);longerlengths as available to reduce number ofjoints.
2.2 SHEATHING JOINT-AND-PENETRATION TREATMENT MATERIALS
A. SiliconeEmulsionSealant:Meeting ASTMC920,TypeS,GradeNS,compatiblewith glass fiber mesh tape and for covering exposed fasteners.
B. Glass-FiberMeshTape:Self-adhering glass-fiber tape, nominal 2 inches (50mm)wide,oftyperecommendedbysheathing and tape manufacturers for use withsiliconeemulsionsealantinsealingjointsin glass-mat gypsum sheathing board and with a history of successful in-service use.
2.3 ACCESSORY MATERIALS
A. Fasteners:Steeldrillscrewsornails,in lengths recommended by sheathing manufacturerforthicknessofsheathingboard to be attached, with organic-polymer or other corrosion- protective coating. Forceiling/soffitapplicationswithDirect-AppliedExteriorFinishSystems(DEFS) andpaintedceilings/soffits,fasteners having a salt spray resistance of more than800hoursaccordingtoASTMB117arerecommended.
1.Forsteelframinglessthan0.0329inch(0.835mm)thick,attachsheathing with steel drill screws complying with ASTMC1002.
2.Forsteelframingfrom0.033to0.112inch(0.84to2.84mm)thick,attachsheathingwithdrillscrewscomplyingwithASTMC954.
3.Forwoodframing,attachwithnailsor screws of type and spacing as recommended by sheathing manufacturer
Part 3-Execution3.1 GYPSUM SHEATHING INSTALLATION
A. ComplywithGA-253,ASTMC1280andmanufacturer’s written instructions.
B. InstallCertainTeedGlasRocSheathingwithpolymercoatedside(logoside)out.Boardsarealso printed with “This side out” on the face side.
C. Cut boards at penetrations, edges, and other obstructionsofwork;fittightlyagainstabuttingconstruction, unless otherwise indicated.
1.Installboardswitha3/8-inch(10mm)setbackwherenon-load-bearingconstructionabuts structural elements.
2.Installboardswitha1/4-inch(6mm)setbackwhere they abut masonry or similar materials that might retain moisture, to prevent wicking.
3.Allownojointsgreaterthan1/8inch(3mm).
D. Coordinate sheathing installation with flashing andjoint-sealantinstallationsothesematerialsare installed in sequence and manner that prevents exterior moisture from passing through completed exterior wall assembly.
E. Applyfastenerssoscrewheadsbeartightlyagainst face of sheathing boards but do not cut into facing.
F. Donotbridgebuildingexpansionjointswithsheathing; cut and space edges to match spacing of structural support elements.
G. HorizontalInstallation:Installsheathingwithlongedgesincontactwithedgesofadjacentboardswithoutforcing.Abutendsofboardsovercentersofstudflanges,andstaggerendjointsofadjacentboardsnotlessthanonestudspacing.Screw-attach boards at perimeter and within field of board to each steel stud.
1.Spacefastenersapproximately8inches (200mm)o.c.(ortighterspacingifrecommended by manufacturer for specific application)andsetbackaminimumof3/8inch(10mm)fromedgesandendsofboards.
3.2 SHEATHING JOINT-AND-PENETRATION TREATMENT
A. Sealsheathingjoints,asrequired,accordingto sheathing manufacturer’s written recommendations.
1.Ifaweathersealisrequiredbeforetheapplication of a water-resistive barrier, apply siliconeemulsionsealantonjointsandtrowelflat.Applysufficientquantityofsealanttocompletelycoverjointsaftertroweling.Sealotherpenetrationsandopenings.Checkwiththe water-resistive barrier manufacturer for installation instructions prior to the application of sealant.
2.Whenthecodesallowtheapplicationasanalternate to separate water-resistive barrier -Applyglass-fibermeshtapetofiberglassreinforcedgypsumsheathingboardjoints,and apply and trowel silicone emulsion sealant to embed sealant in entire face of tape.Applysealanttoexposedfastenerswitha trowel so fasteners are completely covered. Seal other penetrations and openings.
B. Water-ResistiveBarrier:
1. Consult building code authority having jurisdictionforrequirementsregardingwater-resistive barrier installation, if necessary.
3.3 Ceilings and Soffits
A. Finishingisaccomplishedwithoneofthefollowingmethods:
1.Direct-AppliedExteriorFinishSystem(DEFS)isappliedperthemanufacturer’sspecifications.
2.Applynominal2inch(50mm)wideglassmeshdrywalltapeand90minute,setting-typejointcompoundontheboardjoints. Skimcoattheentiresurfacewithasetting-type compound, prime and paint with good quality exterior grade primer and paint per the manufacturer’s recommendations.
GlasRoc® SheathingArchitectural Specifications
GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com
©11-2003 CertainTeed Gypsum. Rev 05-2012
Printed in U.S.A. on recycled paper. CTG-2355/3M
Confidence worth building on.
Confidence worth building on
™
Con�denceAssuranceTime-testedLong-term
GlasRoc®Sheathingfeaturingpatented*Embedded
Glass Reinforced GypsumTM technology is strong,
yetflexibleenoughtobendtocurvedsurfaceslike
thoseatBonnetCreek.
Great Design Deserves Great Protection.
Project (pictured above): BonnetCreek,Orlando,FL
Architect: Smallwood,Reynolds,Stewart& Associates,Atlanta,GA
General Contractor: HuntConstructionGroup,Orlando,FL
TM®CertainTeedandthetagline“Qualitymadecertain.Satisfactionguaranteed.”aretrademarksofCertainTeedCorporation.Allothertrademarksare the property of CertainTeed’s affiliates and related companies.
NOTICE:Theinformationinthisdocumentissubjecttochangewithoutnotice.CertainTeedassumesnoresponsibilityforanyerrorsthatmayinadvertently appear in this document.
*CoveredbyU.S.PatentNo.6,524,679;6,878,321;6,866,492,andotherpatentspending.
©4-2015CertainTeedGypsum. PrintedintheU.S.A.onrecycledpaper.CTG-2362/3M
Recommended