71-‐75, Shelton Street Covent Garden, London, WC2H 9JQ Tel: +44 (0) 20 7692 8729 ENGLAND
Company Nr: 9211607 hKp://www.electroscan.com
info@electroscan.uk.co
Electro Scan|CCTV Benchmark Demonstra6on
Head Office Conway House, Rochester Way DarYord, Kent, DA1 3QY Tel: 020 8636 8822 hKp://www.fmconway.co.uk/
electro scan (uk) limited
Benchmark Loca6on: Richmond Road, lford, England Tuesday 12 May 2015
0.28 l/s Defect Flow
Not Found By CCTV
As Performed by Electro Scan (UK) Limited at the Request of FM Conway Ltd. For A Selected Sewer In The Service Territory of
Thames Water Uflifes Ltd.
CCTV Callout: NONE
Electro Scan Inc. is a California-‐based high tech company engaged in designing and developing breakthrough technologies to automafcally idenffy and report water, sewer, and gas pipeline defects, without third party interpretafon or operator judgment.
Founded by soiware entrepreneur and water industry veteran, Chuck Hansen, Electro Scan’s technology is changing the way uflifes assess, priorifze, and cerffy new and rehabilitated pipes, oien providing informafon that conflicts or reverses condifon assessments that rely on acousfc (listening) or visual (seeing) defects.
Winner of WEF’s Best Innovafve Technology Award (2013) and named Best CleanTech Water & Wastewater Company by Brifsh-‐based New Economy Magazine, Electro Scan finds defects in water, sewer, gas pipes, undetected by legacy inspecfon techniques.
Electro Scan for Sewer Mains
Electro Scan for Private Sewer Laterals
About Electro Scan Inc.
-‐ 1 -‐ © Electro Scan Inc. 2015
About FM Conway Ltd. Head Office Conway House, Rochester Way, DarYord, Kent, DA1 3QY Tel: 020 8636 8822 Cleansing Division Gate 5, Mulberry Way, Belvedere, DA17 6AN Electro Scan Trial Contact Steve Peregrine BEng Hons Senior Technical Manager FM Conway Ltd Mob: 07788 209316
Infrastructure services provider FM Conway was founded in 1961 by Francis M. Conway, who sold his car to buy a single lorry. Now under the ownership of his son, Michael Conway, the fast-‐growing company now employs 1000 staff, with a turnover exceeding £180 Million (US$280 Million). FM Conway delivers the infrastructure services to support, develop and maintain the UK’s vital transport networks, built environment and open spaces. From inifal inspecfon through to design, delivery, refurbishment works and ongoing maintenance, this approach enables us to supply all of the services required to keep the nafon’s infrastructure and open spaces operafng effecfvely and efficiently.
-‐ 2 -‐ © Electro Scan Inc. 2015
About Thames Water U6li6es Ltd.
-‐ 3 -‐
15 million wastewater customers 350 sewage treatment works 4.4 bn litres/day of wastewater treatment
67,000 miles of sewer 2,530 pumping stafons 1.2 million manholes
Thames Water Uflifes Ltd, is a private uflity company responsible for the public water supply and waste water treatment in large parts of Greater London, the Thames Valley, Surrey, Gloucestershire, Wiltshire, Kent, and some other areas of the United Kingdom.
Thames Water is the UK's largest water and wastewater services company, and supplies 2.6 gigalitres of drinking water per day, and treats 4.4 gigalitres of wastewater per day. Thames Water's 15 million customers are 27% of the UK populafon.
Thames Water is regulated under the Water Industry Act 1991 owned by Kemble Water Holdings Ltd, a consorfum formed in late 2006 by Australian-‐based Macquarie Group's European Infrastructure Funds specifically for the purpose of purchasing Thames Water.
WASTEWATER COLLECTION INFRATRUCTURE PROFILE
© Electro Scan Inc. 2015
Project Loca6on -‐ Richmond Road, lford, England
12 May 2015 -‐ 4 -‐ © Electro Scan Inc. 2015
Findings and Conclusions
-‐ 5 -‐ © Electro Scan Inc. 2015
• Electro Scan idenffied 11 Defects compared to Zero Defects found by CCTV. • Total Defect Flow idenffied by Electro Scan is esfmated to be 0.92 l/s (79,748 l/d). • The seven (7) highest defect flows found by Electro Scan contributed 0.88 l/s or 96% of defect flow. • The Electro Scan survey took six minutes to complete, with a final report available in five minutes. • CCTV Report by FM Conway does not indicate numerous defects shown on the CCTV Video,
including an Acfve Break-‐in Tap. • Any use of past CCTV inspecfons as part of a Big Data analysis should be approached with caufon,
or risk inappropriate conclusions to determining CrifcalSewers.
Findings
Conclusions • Electro Scan found numerous and significant defect flows not reported by the CCTV Report.
• Had FM Conway adopted emerging U.S. sewer condifon assessment standards of Electro Scanning sewer lines, first, it could have had its CCTV operator use defect locafons established by Electro Scan to pan, flt, zoom, and capture detail images and assess the top seven (7) defect flows found by Electro Scan.
• Given the proximity of the Electro Scan survey to major roadways (A118), this sewer has a high risk of flooding during either a severe or prolonged wet weather event.
• FM Conway would gain a major compeffve advantage over its Compeftors (i.e. CCTV Only Contractors) by complefng Electro Scan surveys before all CCTV inspecfons.
TQ44861405 End of Scan
(Downstream)
TQ44861404 Start of Scan (Upstream)
-‐ 6 -‐ © Electro Scan Inc. 2015
TQ44861404 to TQ44861405 SITE MAP
VCP, 300mm Diameter, 15m Length
-‐ 7 -‐ © Electro Scan Inc. 2015
TQ44861404 to TQ44861405 SITE PHOTOGRAPHS
-‐ 8 -‐ © Electro Scan Inc. 2015
LARG
E TH
RESH
OLD
MED
IUM THR
ESHO
LD
SMAL
L TH
RESH
OLD
�
� �
�
�
� �
-‐ 9 -‐ © Electro Scan Inc. 2015
ELECTRO SCAN CCTV
0 Defects 11 Defects
12-‐05-‐2015 12-‐05-‐2015 Date Completed
Top Seven (7)Worst Defects Account for 94% of Defect Flow 7.0 TBA Tap, Break-‐in, Ac6ve 00:00:45
Missed Call Out
�
� �
� �
� �
electro scan (uk) limited 71-‐75, Shelton Street Covent Garden, London, WC2H 9JQ Tel: +44 (0) 20 7692 8729 ENGLAND
Company Nr: 9211607
-‐ 10 -‐ © Electro Scan Inc. 2015
� � � � � � �
74,895
Top Seven (7)Worst Defects Account for 94% of Defect Flow
While Defect � has the fich largest defect ! Current it’s Area (Length and Height) shows it is the third largest defect flow.!
Second highest defect current, but fourth largest defect flow.!
0.88 Total Largest Defects 7 RANKED BY WORST
DEFECT FLOW
12.9m (CCTV)
3.2m (ES)
10.5m (CCTV)
5.5m (ES)
Electro Scan Compared to CCTV
�
�
-‐ 11 -‐ © Electro Scan Inc. 2015
CCTV Callout: NONE
CCTV Callout: NONE
Esfmated Defect Flow 0.28 l/s
Esfmated Defect Flow 0.13 l/s
RANKED BY WORST
DEFECT FLOW
Esfmated Defect Flow 0.13 l/s
9.8 m (CCTV)
6.3m (ES)
Esfmated Defect Flow 0.12 l/s
6.7m (CCTV)
9.4m (ES)
�
�
-‐ 12 -‐ © Electro Scan Inc. 2015
CCTV Callout: NONE
CCTV Callout: NONE
Electro Scan Compared to CCTV RANKED BY WORST
DEFECT FLOW
1.3m (CCTV)
14.7m (ES)
2.9m (CCTV)
13.1m (ES)
-‐ 13 -‐ © Electro Scan Inc. 2015
�
�
CCTV Callout: NONE
CCTV Callout: NONE
Esfmated Defect Flow 0.09 l/s
Esfmated Defect Flow 0.06 l/s
Electro Scan Compared to CCTV RANKED BY WORST
DEFECT FLOW
� 3.6m (CCTV)
12.3m (ES)
-‐ 14 -‐ © Electro Scan Inc. 2015
CCTV Callout: NONE
Esfmated Defect Flow 0.05 l/s
Electro Scan Compared to CCTV RANKED BY WORST
DEFECT FLOW
London UK 12:26pm
Flash Report – Scan Available for Review
London UK 12:30pm
Onsite Access to Scan in CrifcalSewers
London UK 12:15pm
Probe Set and Ready Start of Scan
London UK 12:21pm
End of Scan, Saved on Laptop
London UK 12:26pm
AWS UK Server
Start of Scan-‐to-‐Final Report In Less Than 11 Minutes
-‐ 15 -‐ © Electro Scan Inc. 2015
Electro Scan Repor:ng of Results Available Onsite
It should be noted that if contractors are only allowed to visit a site once, then they could Electro Scan each Sewer, first, then review Electro Scan’s internafonal patent-‐pending reporfng to instruct the CCTV contractor which key defects to evaluate. Otherwise, the Contractor risks incorrectly assessing the sewer main by only using CCTV, and further risks client assets by missing large defect flows that may be suscepfble to flooding & infiltrafon.
®
The Cri6calSewers cloud applica6on delivered onsite repor6ng 5 minutes acer its survey was complete.
-‐ 16 -‐ © Electro Scan Inc. 2015
Supplemental Informa6on
Actual Timeline From Arrival To Departure 12 May 2015
11:20am Electro Scan Arrival 11:40am PowerPoint Overview Presentafon Complete 11:45am Electro Scan Setup (Waifng on Arrival of Jeyng Lorry) 12:00 Jeyng Lorry Arrival and Posifoning at DWN MH 12:10pm Jeyng Lorry Setup Complete | Jeyng to UPS MH 12:15pm Electro Scan Probe Setup in UPS MH. Begin Scan 12:20pm Electro Scanning Complete. Scan Saved on Van PC 12:26pm Confirmed Upload to Amazon Web Service (AWS) 12:26pm Scan Data Processing Complete | Loaded to CS 12:30pm Proof of Final Report in CrifcalSewers® 12:45pm Electro Scan Departure
-‐ 17 -‐ © Electro Scan Inc. 2015
BEST PRACTICE FOR CONDITION ASSESSMENT UNDER DRY WEATHER AND WET WEATHER CONDITIONS Crifcal Sewers®
electro scan (uk) limited electro scan (uk) limited
Recommended by the Office of Water Programs & US EPA
-‐ 18 -‐ © Electro Scan Inc. 2015
-‐ 19 -‐ © Electro Scan Inc. 2015
Electro Scan Sewers To Measure Defect Flows, By LocaAon, Then CCTV Worst
-‐ 20 -‐ © Electro Scan Inc. 2015
Electro Scan Sewers To Measure Defect Flows, By LocaAon, Then CCTV Worst
-‐ 21 -‐ © Electro Scan Inc. 2015
Electro Scan Sewers To Measure Defect Flows, By LocaAon, Then CCTV Worst
CCTV is no longer recommended as the singular tool to assess sewers due to inherent problems to determine its water fghtness or priorifse defects for pre-‐ and post-‐rehabilitafon.
The Dirty Dozen
The Twelve Dirty Secrets of CCTV Inspecfon.
*
* -‐ 22 -‐ © Electro Scan Inc. 2015
1. CCTV Inspecfon Is a Dry Weather Assessment Tool -‐-‐ Not Well Suited in Assessing Wet Weather Events.
-‐ 23 -‐ © Electro Scan Inc. 2015
2. CCTV surveys must have an empty pipe.
-‐ 24 -‐ © Electro Scan Inc. 2015
3. CCTV cannot judge pipe wall integrity if too much grease i.e.
Any WRc/PACP Call Outs for ‘Grease’ typically miss poten6al defects.
-‐ 25 -‐ © Electro Scan Inc. 2015
4. CCTV surveys tend to rate ‘Roots’ but not leakage potenfal.
-‐ 26 -‐ © Electro Scan Inc. 2015
5. CCTV Surveys Rate Evidence of Encrustafons, but Not Defects.
In several EPA-‐funded projects pipes were found to ‘PASS’ water pressure tests, but had High Rates of Encrustafon, i.e. Entrustafons may give a False Posifve, while Electro Scan located and measured potenfal defect flow rates. EncrustaAon is (STILL) not an approved method of rehabilitaAon!
-‐ 27 -‐ © Electro Scan Inc. 2015
5. CCTV operators oien use different codes for same defect.
-‐4 -‐3 -‐2 -‐1 0 1 2 3 4
49
90 46
24 3 2
40 28
19 6
Parallel TV inspec:ons 307 CCTV Operators
Different Condifon Classificafon
55% Same Condifon Classificafon Same Degree
16%
29%
Same Condifon Classificafon Different Degree
55%
-‐ 28 -‐ © Electro Scan Inc. 2015
Example: Visual Defect May Not Be Coded Correctly.
Same Pipe
Locafon
Different Defect Code
-‐ 29 -‐ © Electro Scan Inc. 2015
6. CCTV operators oien use the same code for different defects.
-‐ 30 -‐ © Electro Scan Inc. 2015
7. CCTV Operators Frequently Miss Enter Defect Codes.
-‐ 31 -‐ © Electro Scan Inc. 2015
8. CCTV operators cannot rate, what they cannot see.
Mortar Tarred Rope or Gasket
Collar Spigot -‐ 32 -‐ © Electro Scan Inc. 2015
9. Silt may prevent CCTV Operator from seeing boKom of pipe.
-‐ 33 -‐ © Electro Scan Inc. 2015
10. Mulfple CCTV reports on the same pipe lack repeatability.
6 Different CCTV Reports, From 3 Different Operators. Source: Long Beach Water Department, 3-‐17-‐2015
NASTT No-‐Dig Presenta:on.
CCTV Operators A B C
-‐ 34 -‐ © Electro Scan Inc. 2015
11. Visual Defects May Not Be Coded or Recorded At All.
Key Problem found with CCTV report submiked on Thames Water benchmark. -‐ 35 -‐ © Electro Scan Inc. 2015
12. Cleaning a line oien removes tell-‐tale signs of defects.
-‐ 36 -‐ © Electro Scan Inc. 2015
B. How Does It Work? Electro Scan is designed to automafcally assess non-‐conducfve pipes (e.g. asbestos concrete, brick, clay, cement, plasfc, reinforced concrete, etc.), where no electrical current should ever be able to “leak” or escape into the ground from inside the pipe – unless, of course, there is a crack or break in a pipe. Electro Scan’s technology uflizes a low voltage/high frequency patent-‐pending process to automafcally find & measure defects not commonly detected by closed-‐circuit television (CCTV) cameras or acousfcal devices. Using its internafonal patent-‐pending technology that measures the variafon of electrical current inside pipes, Electro Scan automafcally locates and measures potenfal leaks in GPM.
A. What Does Electro Scan Do, That CCTV Cannot? Answer: Find sources of infiltrafon and cracks. Infiltrafon is a key factor causing Sanitary Sewer Overflows (SSOs) and Combined Sewer Overflows (CSO) caused by cracks & defects found in manholes, sewer mains, service connecfons, and laterals. Given the limitafon of CCTV – i.e. not able to visually find leaks -‐-‐ Electro Scan automafcally finds , locates, and measures the amount of infiltrafon (i.e. in gallons per minute) caused by defects. Electro Scan can also cerffy newly installed, recently repaired and rehabilitated pipe lining.
C. Who Has Endorsed or Used Electro Scan? Electro Scan has undergone numerous U.S. EPA studies and found superior to CCTV in finding the locafon and quanfficafon of defects that cause leaks. Electro Scan is the only company with products in compliance with ASTM Standard F2550-‐13, just approved for another five years by ASTM CommiKee F36. Winning internafonal acceptance, Electro Scan has recorded nearly 1 million feet of scans in the U.S., England, Japan, Australia, and New Zealand, and represents the next generafon in defect locafon and cerfficafon of pipeline repairs & rehabilitafon, able to work in wet weather and dry weather condifons.
Electric “Spikes” Show Defect Locafons,
Intensity & Esfmated Gallons per Minute.
What is Electro Scan?
-‐ 37 -‐ © Electro Scan Inc. 2015
Overview of Basic Field Operafons
0
10
20
0 100 150 200 250 300 DISTANCE
ELEC
TRIC
CU
RR
ENT
50
10
20
40 60 80 100 120 DISTANCE IN METERS
ELEC
TRIC
CU
RR
ENT
20
Electro Scan’s internafonal patent pending data processing, integrafon with CCTV
equipment, and cloud compufng plaYorm provides a near instant unbiased automated
assessment of non-‐conducfve pipes, including esfmated leakage rates (l/s) and
defect flow locafons (within 1cm).
Flow
0
-‐ 38 -‐ © Electro Scan Inc. 2015
Real Time Readings
Distance
Pressure
Rate of Travel
Defect Current
Automafc In-‐Field Real-‐fme Data Capture
-‐ 39 -‐ © Electro Scan Inc. 2015
Soiware-‐as-‐a-‐Service Cloud Reporfng
-‐ 40 -‐ © Electro Scan Inc. 2015
Fire Wall Password, Protected Severn Trent Account
Authorized Electro Scan Contractor
Project Scans – By Date
Electro Scan Summary
From SP31380501 To SP31380601
Scan Detail Report
Office Upload if WIFI is Not
Available in the Field
Online Results Available in Minutes
-‐ 41 -‐ © Electro Scan Inc. 2015
Locafon & Quanfficafon of Defect Flows
Defect Counts
Esfmated Total Defect Flows.
Tabular Data Available for Export
Scan Graph for Visual Reference*
-‐ 42 -‐ © Electro Scan Inc. 2015
What Does It Tell Me*?
* That We Don’t Already Know?
Esfmated Infiltrafon
Flow: 5.2 GPM
Finds Defects Missed By CCTV
A. For Exis6ng Mains & Laterals
Finds All Post-‐Rehab Defects
B. For Post-‐Rehab, CIPP & Points Repairs
87 Large Defects Total Es6mated GPM 226
1 Large Defect No PACP Quan6fica6on
-‐ 43 -‐ © Electro Scan Inc. 2015
Defective Connection
What Are The Key Components? TV Truck -‐ Field Applicafon
TV Truck -‐ Operator’s Console
Cloud Applicafon
TV Truck – Scan Summary
Probe Funnel Plugs
Mobile Wi-‐Fi
Electro Scan Patch Panel and Data Transfer
Grounding Reel & Rod
Electro Scan CCTV Switchover
Probe Calibrator
-‐ 44 -‐ © Electro Scan Inc. 2015
While ‘Large Current Readings over a Large Area’ oien result in the largest esfmated l/s or Defect Flow, frequently the largest esfmated l/s may be caused by smaller current readings over larger areas (Right). From 12,000 – 20,000 data points may be collected for an average 100m sewer main with Electro Scan represenfng the first automated tool to idenffy & measure leaks to the closest 1 cenfmeter or 0.4 inch.
Electro Scan’s standard Graph displays the Maximum Defect Current and Lengths (i.e. from and to start and end points of defects), with its Crifcal Sewers® cloud applicafon providing an esfmated Liters per Second (Defect Flow) based on the Defect Area and Electric Current sustained over that Area.
(Above) Sample processed data.
How Does It Calculate l/s Defect Flows?
-‐ 45 -‐ © Electro Scan Inc. 2015
How Does It Manage My Data?
-‐ 46 -‐ © Electro Scan Inc. 2015
What Industry Standard Exists?
Originally approved in 2006, ASTM F2550 was recently modified to expand its use to include ‘tes:ng and cer:fica:on of pipe repairs, renewal, and new construc:on.’ The revised standard was approved October 1, 2013, by unanimous vote of CommiUee F36, for renewal for a five-‐year extension.
ASTM F2550-‐13
-‐ 47 -‐ © Electro Scan Inc. 2015
What Textbooks or Manuals? “Electro Scan has proved it belongs in our new edifon by finding leaks that CCTV can’t and renewing their
ASTM Standard*.”
Coming… October 2014 7th Edifon
Kenneth Kerri, Ph.D.
Over 80,000 Copies Sold
Coming Summer 2015
-‐ 48 -‐ © Electro Scan Inc. 2015
Best Innovafve Technology, WEF
Best Innovafve Product, No-‐Dig NASTT
Best CleanTech Company
Best Water & Sewer Company
What Major Awards Has It Won?
-‐ 49 -‐ © Electro Scan Inc. 2015
UKSTT Best Small Scheme Project
Who Backs Electro Scan? Experience • Experfse in business start-‐up, growth, and mergers &
acquisifons. • Principal investor in Electro Scan Inc. • Co-‐holder of numerous patent-‐pending filings,
trademarks, and trade names. • Leadership, business counseling, and turnaround
management. • Former Director & CEO of Hansen Informafon
Technologies. Sold to Infor Global $100 million. Electro Scan Company Awards • Finalist, Europe’s GreenTec Award for Water & Sewage
(Announced May 2014) • The New Economy Clean Tech Award for Water &
Wastewater Solufons, 2013 • PURE Award for Innovafon, South West Water, UK, 2013 • WEF Innovafve Technology Award, 2013 • SacAddy Award Best Markefng Campaign 2013 • NASTT/No-‐Dig Joseph L. AbboK Jr., Award for Best
Product Innovafon, 2013 Major Affilia:ons • AWWA, NASSCO, NASTT, WEF, AOPA • Chairman, ASTM CommiKee F36.20, Inspecfon and Renewal of Water and
Wastewater Infrastructure (Feb 2014) Educa:on • MBA, UCLA, 1982 • BS, U.C. Berkeley, 1978
About Chuck Hansen Chuck Hansen, age 59, is a Public Works and IT veteran, implemenfng some of the largest Asset Management, Building Permit, and Uflity Billing applicafons for over 1,000 water, sewer, roadway, and railway clients throughout the world. When Chuck sold his soiware company in 2007, cumulafve Hansen client databases held over 1 million closed-‐circuit television (CCTV) inspecfon reports, including over 6 million pipeline defects. In 1990, working with the City of Houston Wasteload Control Branch, Chuck co-‐developed the first nafonal CCTV standard, used by +250 TV inspecfon trucks to conduct a comprehensive crifcal sewers database in response to a Region VI EPA consent decree. Chuck spearheaded development of the first asset-‐specific accounfng system in response to new internafonal financial standards in Australia and New Zealand, adopted by all local councils and uflifes in New Zealand. Later, he led his internafonal soiware programming team to design, development, and deploy, integrated customer service, billing, building permit, and property tax accounfng systems. Partnering with San Francisco-‐based private equity firm Golden Gate Capital, Chuck doubled the size of his company over two-‐years through acquisifons, new web-‐based products, and internafonal expansion, exifng the business he started with his father and older brother in 2007. Chuck lives in Sacramento, California with his wife, Deborah, a civil engineer,
his three daughters and grown son, nearby.
Chuck Hansen
1983-‐2006
2006-‐2007
2011-‐Present
-‐ 50 -‐ © Electro Scan Inc. 2015
-‐ 51 -‐ © Electro Scan Inc. 2015
Developer of first U.S. CCTV standards in 1989. Now developing standards for CCTV standards for water mains.
Chuck Hansen
1995 First German Patents Filed, based on German government research funding. Patents filed, but abandoned.
2001 IKT Benchmark Study, including Seba Dynatronic GmbH and Prof. Dr.-‐Ing. Stein & Partner GmbH, Bochum.
2003 First prototypes developed by MetroTech, San Jose, CA
2004 WERF – An Examinafon of Innovafve Methods Used in the Inspecfon of Wastewater Systems 5.1.5.1 Focused Electrode Leak Locafon System (Fell-‐41) published.
2006 ASTM F2550-‐06 – Approved. First Presentafons at ASCE Pipeline.
2009 Condifon Assessment of Wastewater Collecfon Systems EPA/600/R-‐09/049, 4.3.1 Electrical Leak Locafon Method, published.
2010 State of Technology for Rehabilitafon of Wastewater Collecfon Systems, EPA/600R-‐10/078, including Electro Scan, published.
2011 US EPA Field Demonstrafon of Condifon Assessment Technologies for Wastewater Collecfon Systems, Kansas City, MO. First benchmarking of CCTV and Electro Scan, published.
2011 Electro Scan Inc., a Delaware Corporafon, founded by Chuck Hansen. Acquires intellectual property and assets of PDQ Scan, LLC and Leakbusters Inc.
2012 US EPA/WERF Sewer Lateral Field Assessment Project, Milwaukee, WI. Projects in New Zealand and the United Kingdom. Three (3) U.S. Patent Filed covering new product & data advancements.
2013 First UK Trials with Wessex Water. ASTM F2550-‐13 – Approved. Industry Awards: NASTT/No-‐Dig Award – Best New Product. WEF -‐ Best Innovafve Technology Award, European GreenTec Award Nominafon, New Economy Magazine -‐ Best CleanTech for Water & Sewer, South West Water, England – PURE Award. Begins Electro Scan Trials for Water Mains.
2014 Innovafon Bullefns issued by Severn Trent. Sales to Cincinnaf MSD, Miami-‐Dade, FL, Nashville Metro, and over 100 Uflifes, Contractors, and Dealers. Electro Scan opens in Dublin, Frankfurt, London, Melbourne
2015 UKSTT Award for Best Small Scheme for Severn Trent Project. Major tender released for 1,000km projects. Release of Electro Scan for Water with mulf-‐sensor probe including Electro Scan, CCTV, Acousfc, Pressure, offered exclusively by Electro Scan Services. New Chapter published in U.S. Sewer Assessment Manual. New standards for CCTV of water mains.
Electro Scan Milestones 2002
2006
2012
2013 2015
1995
2011
-‐ 52 -‐ © Electro Scan Inc. 2015
Facebook www.facebook.com/Electro-‐Scan-‐Inc/214255938644317
YouTube www.youtube.com/SewerElectroScan
Twiker @electroscan
Instagram hKp://instagram.com/electroscannow
-‐ 53 -‐ © Electro Scan Inc. 2015
1745 Markston Road Sacramento, California 95825-‐4026 USA info@electroscan.com | Tel: +1 916-‐779-‐0660 | www.electroscan.com
The Black Church, St Mary’s Place, Dublin 7, IRELAND info@electroscan.com Tel: +35 3 (0) 1 687 4514 VAT: IE 3237750VH
71-‐75, Shelton Street Covent Garden, London, WC2H 9JQ, ENGLAND info@electroscan.co.uk, Tel: +44 (0) 20 7692 8729, Company Nr: 9211607
CORPORATE HEADQUARTERS
Lyoner Straße 14, Frankfurt, D-‐60528 GERMANY Tel: +49 69 6655 4132
Suite 504 365 LiKle Collins Street Melbourne VIC 3000 AUSTRALIA Tel: +61 3 8609 1246
Suite 2201 250 Yonge Street Toronto, Ontario, M5B 2L7 CANADA Toll Free: 844 882 9280
elektro scan GmbH elektro scan GmbH electro scan australia pty ltdelectro scan canada ltd
-‐ 54 -‐ © Electro Scan Inc. 2015
Recommended