View
227
Download
0
Category
Preview:
Citation preview
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 1/38
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 2/38
LindabDamper ®
Right to alterations reserved.
32
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
A 15................................................. 22
DRU ................................................ 4-8
DSU ................................................ 10
DTBCU 100 - 630........................... 17
DTBOU 100 - 630........................... 17
DTU................................................. 11
DTBU 100 - 315.............................. 15
DTBU 355 - 630.............................. 16
DTMU ............................................. 12
DTWU ............................................. 12FK 500/8 ......................................... 22
FK 1000/8 ....................................... 22
FM 24 - SR ..................................... 21
FMDRU........................................... 31/35-37
FMU................................................ 31-34
IBU.................................................. 24-30
KM 24/220...................................... 18
PSDRU............................................ 9
RK 8................................................ 23
SF 24/230 ....................................... 20
SKU................................................. 38SM 24/220...................................... 19
TASU............................................... 13
TATBU............................................ 14
TATU............................................... 13
TDRU.............................................. 9
VF.................................................... 22
Accessories for motorised dampers 22-23
Bypass dampers............................... 13-14
Closing dampers, sealed................. 10-12
Damper motors ................................ 18-21
Damper summary............................. 3
Flow meter........................................ 31-37
Iris damper........................................ 24-30
Motorised dampers.......................... 15-17
Regulating dampers......................... 4-9
Slide damper..................................... 38
Type Page Product Page
CONTENTS
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 3/38
LindabDamper ®
33
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Sealing classApplication 1 2 3 Page Note
For Forregulation closing
Manual operation Volume DRU 4regulation DSU 10
Manual operation DTU 11
Manual operation DTMU 12DTWU 12
Manual operation Dampers can TDRU 9be cleaned PSDRU 9
Manual operation Dampers in TASU 13Tee-branches TATU 13
Volume regulation Dampers for flow IBU 24 Iris damperand measurement measurement
regulating andmeasuring volumeflow FMDRU 31
Motor control Automatically TATBU 14controlled dampersin Tee-branches
Motor control Automatically DTBU 15controlled dampers DTBCU 17
DTBOU 17
Slide dampers SKU 38
DAMPER SUMMARY
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 4/38
LindabDamper ®
Right to alterations reserved.
34
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
OrderingProduct code: DRU - aaa
Type
∅d1
DRU
The damper is designed so that it can also be built intoinsulated duct systems.The damper cup has marks showing the position of the damperblade between 0 and 90°C. The damper blade can also belocked in position with screws.The damper cup allows for up to 50 mm of insulating material.
∅d1
50
Regulating damper
Description
Dimensions
100
∅d1nom kg
63 0.4
80 0.4
100 0.5
112 0.5
125 0.6
140 0.6
150 0.7
160 0.7
180 0.9
200 1.0
224 1.1
250 1.4
280 1.5
300 1.7
315 1.8
355 2.1
400 2.7
450 3.1
500 3.5
560 3.9
600 4.6630 5.2
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 5/38
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 6/38
LindabDamper ®
Right to alterations reserved.
36
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Regulating damper DRU
Technical data
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 7/38
LindabDamper ®
37
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Regulating damper DRU
Technical dataSound data for DRUThe sound power level LW(dB) for the duc t in accordance with the octave bands 63-8000 Hz as a function of the dimension, volumeflow and pressure drop.
dim Pressure Velocity approx. 3 m/s Velocity approx. 6 m/s Velocity approx. 9 m/s∅d
1drop(Pa) Frequency Hz Frequency Hz Frequency Hz
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
500 57 57 59 58 53 46 39 38 63 65 66 65 59 52 44 43 71 72 75 72 66 58 49 48300 55 54 53 53 50 43 34 31 63 65 63 62 57 50 39 36 70 75 73 70 63 55 43 40
63 200 55 57 56 50 46 38 27 26 64 67 65 58 53 44 32 31 73 75 73 66 61 50 36 35100 55 56 52 46 39 27 17 13 67 66 64 56 48 33 20 16 77 75 73 65 56 38 23 1950 56 53 48 40 34 20 10 7 70 68 63 52 44 26 13 10 - - - - - - - -
500 65 65 65 65 59 55 49 46 67 67 67 67 60 57 50 47 70 70 70 70 63 60 53 49300 63 63 60 60 54 48 42 36 66 66 63 63 56 50 44 38 70 70 67 67 60 54 47 40
80 200 63 63 60 54 51 43 34 29 65 65 62 56 53 44 35 30 70 70 67 60 57 48 38 32100 55 60 53 48 43 30 23 15 59 65 57 51 46 32 24 16 66 72 63 57 51 36 27 1850 56 54 47 43 36 25 16 9 59 59 52 47 40 27 17 10 - - - - - - - -
500 67 64 64 57 54 48 48 48 72 68 68 62 59 52 52 52 78 75 75 67 64 57 57 57300 62 61 60 54 51 45 42 42 68 68 68 59 56 50 47 47 75 74 73 65 61 54 51 51
100 200 58 58 58 50 48 40 37 37 65 65 64 57 54 45 42 42 74 73 73 64 59 50 47 46100 58 55 53 46 41 34 26 24 68 66 62 54 48 40 31 29 79 75 71 62 56 46 36 3350 55 53 48 42 35 26 22 18 69 67 60 53 44 33 28 22 - - - - - - - -
500 71 68 65 59 56 50 50 47 76 73 70 63 60 53 53 50 83 79 76 68 65 58 58 54300 66 66 60 55 52 46 43 40 73 73 67 60 57 51 48 44 79 79 72 66 62 55 52 48
125 200 65 62 57 51 46 41 38 38 74 71 65 59 53 47 43 43 82 78 71 65 58 51 48 48100 64 59 53 47 39 34 29 27 77 70 63 55 47 40 35 32 84 78 70 61 51 45 39 3550 63 54 50 41 36 27 25 20 80 68 60 51 43 34 32 26 - - - - - - - -
500 68 67 64 59 55 53 52 51 72 71 68 62 59 55 54 53 78 77 74 67 63 60 59 58300 63 62 59 55 52 49 46 45 67 66 64 58 55 52 49 48 75 75 71 65 61 58 54 54160 200 61 58 56 50 48 42 40 40 68 65 62 56 53 47 44 44 76 73 69 63 59 53 50 50
100 59 54 50 45 40 35 33 31 70 64 60 53 48 42 39 38 77 73 69 61 54 48 45 4450 54 50 46 37 33 29 25 25 69 64 58 48 42 37 32 32 - - - - - - - -
500 70 64 61 55 52 52 55 55 75 68 65 59 55 55 59 59 83 76 72 65 61 61 65 65300 67 62 56 50 48 45 48 48 74 68 62 55 52 51 53 52 84 78 71 64 61 57 60 60
200 200 62 57 55 47 44 42 42 42 71 65 62 53 50 48 47 47 83 76 71 62 58 55 54 5410057 52 48 41 39 36 34 34 69 64 58 50 47 44 42 42 83 76 69 59 56 53 50 50
50 51 45 41 36 32 32 28 28 63 56 51 44 39 39 34 34 - - - - - - - -
500 69 66 59 53 50 54 53 52 71 67 61 56 53 56 55 54 78 75 68 61 58 61 60 59300 63 61 55 50 47 46 48 47 66 63 57 51 48 47 51 48 75 72 65 59 55 55 59 55
250 200 59 57 52 46 44 41 44 44 63 60 55 49 46 44 46 46 72 69 63 57 55 54 54 53100 56 52 45 41 38 36 34 31 63 57 51 45 43 40 38 35 75 69 60 56 52 49 45 4250 52 48 40 38 34 30 28 24 61 56 47 45 40 38 33 28 - - - - - - - -
500 68 65 59 53 50 50 53 50 74 71 65 58 55 55 58 55 82 78 71 64 60 60 54 60300 62 59 54 49 46 45 49 43 69 66 60 54 51 51 54 48 78 74 68 61 57 57 61 54
315 200 60 55 50 45 43 40 43 40 70 64 58 52 49 48 49 46 79 72 66 59 58 57 56 52100 54 52 45 41 38 36 36 31 66 63 55 50 47 46 44 39 76 72 64 57 54 52 50 4450 49 49 43 38 34 32 30 24 64 64 56 49 45 42 40 32 - - - - - - - -
500 79 73 67 62 57 60 59 58 82 75 68 65 59 62 61 60 88 81 74 70 62 66 65 64300 72 66 60 54 51 51 51 51 77 70 64 58 56 55 54 54 84 77 70 63 62 61 60 60
400 200 67 62 56 50 48 48 48 45 74 68 62 56 53 52 52 49 82 75 68 61 60 59 58 54100 61 56 49 44 42 39 39 34 72 66 58 53 49 47 46 40 83 76 67 60 58 55 53 4750 57 52 44 39 37 35 34 26 72 67 56 50 47 44 44 33 - - - - - - - -
500 84 77 70 64 63 62 61 60 85 78 71 65 64 63 62 61 91 84 76 68 67 68 68 67300 77 70 64 58 54 54 58 58 80 74 67 60 57 57 60 60 88 80 73 66 62 62 66 66
500 200 71 65 59 53 50 50 50 47 77 70 64 58 56 55 54 51 85 78 72 65 63 61 60 57100 63 58 53 47 46 44 42 37 72 66 60 55 53 51 49 43 82 75 70 63 60 57 55 5050 59 52 47 44 42 38 38 31 71 63 57 54 51 46 46 37 - - - - - - - -
500 88 80 73 69 66 64 63 62 90 83 75 71 68 67 65 64 96 88 80 76 72 72 70 68300 82 75 69 65 62 61 58 55 84 77 70 67 63 62 61 56 92 84 77 73 69 68 68 61
630 200 78 72 65 62 59 55 55 49 80 74 67 64 60 57 57 50 89 82 75 71 67 63 63 56100 71 66 59 54 50 46 45 40 78 71 66 59 56 49 47 44 90 82 76 68 63 58 55 50
50 66 58 53 48 43 40 39 30 77 68 62 57 51 45 48 36 - - - - - - - -
Volume flow 15 l/s Volume flow 30 l/s Volume flow 45 l/s
Volume flow 25 l/s Volume flow 50 l/s Volume flow 75 l/s
Volume flow 40 l/s Volume flow 80 l/s Volume flow 120 l/s
Volume flow 60 l/s Volume flow 120 l/s Volume flow 180 l/s
Volume flow 100 l/s Volume flow 200 l/s Volume flow 300 l/s
Volume flow 150 l/s Volume flow 300 l/s Volume flow 450 l/s
Volume flow 250 l/s Volume flow 500 l/s Volume flow 750 l/s
Volume flow 400 l/s Volume flow 800 l/s Volume flow 1200 l/s
Volume flow 600 l/s Volume flow 1200 l/s Volume flow 1800 l/s
Volume flow 1000 l/s Volume flow 2000 l/s Volume flow 3000 l/s
Volume flow 10 l/s Volume flow 20 l/s Volume flow 30 l/s
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 8/38
LindabDamper ®
Right to alterations reserved.
38
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Velocity approx. 12 m/s Velocity approx. 15 m/sdim Pressure∅d
1drop Frequency Hz Frequency Hz(Pa) 63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
500 75 77 80 77 71 62 52 52 76 78 81 78 72 62 53 52300 77 78 77 75 69 60 47 44 79 80 79 78 71 62 49 45
63 200 78 80 79 71 65 53 39 37 - - - - - - - -100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
500 75 75 75 75 68 64 56 53 80 80 80 80 72 68 60 56300 75 75 71 71 64 57 50 43 79 79 75 75 68 60 53 45
80 200 75 75 71 65 61 51 41 34 - - - - - - - -
100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
500 84 81 80 72 68 62 61 61 88 85 84 76 72 65 64 64300 81 80 79 70 67 59 56 55 86 85 84 74 70 62 59 58
100 200 80 80 79 69 66 55 51 51 - - - - - - - -100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
500 89 85 81 73 69 62 62 58 91 87 83 75 71 63 63 59300 86 86 79 71 68 60 56 53 89 88 81 73 69 62 58 54
125 200 89 85 78 70 63 56 52 52 - - - - - - - -100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
500 84 84 80 72 68 65 65 65 89 89 85 77 73 69 69 69300 81 81 78 70 67 63 59 59 87 87 83 76 72 68 64 64
160 200 84 80 77 69 66 58 55 55 - - - - - - - -100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
500 90 82 78 72 67 66 71 70 93 85 81 73 71 70 74 73300 92 84 78 71 67 63 67 66 95 87 81 72 68 66 69 68
200 200 90 83 79 69 65 62 61 60 - - - - - - - -100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
500 87 83 76 68 64 68 68 68 94 90 82 74 70 74 74 74300 84 80 73 67 65 64 62 61 91 87 80 72 70 69 72 68
250 200 82 79 72 64 63 63 62 61 - - - - - - - -100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
500 89 85 77 69 68 67 69 65 92 88 80 72 71 70 72 68300 85 81 74 66 64 64 66 59 89 85 78 70 68 68 70 62
315 200 86 79 72 65 63 62 64 58 - - - - - - - -100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
500 95 87 79 75 67 71 70 69 98 90 82 78 70 74 73 72
300 91 83 76 69 67 66 65 64 94 86 79 71 70 69 68 67400 200 89 82 75 69 67 64 63 60 - - - - - - - -
100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
500 96 88 80 72 70 73 72 71 102 94 85 78 75 77 77 76300 93 85 78 70 66 66 70 70 99 91 83 74 70 70 74 74
500 200 91 84 76 70 68 66 65 61 - - - - - - - -100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
500 103 95 86 82 77 77 76 73 107 98 90 85 81 81 80 76300 100 91 83 79 75 75 74 66 105 96 88 83 79 79 79 70
630 200 98 90 82 78 74 70 70 62 - - - - - - - -100 - - - - - - - - - - - - - - - -50 - - - - - - - - - - - - - - - -
Volume flow 40 l/s Volume flow 45 l/s
Volume flow 60 l/s Volume flow 75 l/s
Volume flow 100 l/s Volume flow 120 l/s
Volume flow 160 l/s Volume flow 180 l/s
Volume flow 240 l/s Volume flow 300 l/s
Volume flow 600 l/s Volume flow 750 l/s
Volume flow 2400 l/s Volume flow 3000 l/s
Volume flow 4000 l/s Volume flow 4500 l/s
Volume flow 1600 l/s Volume flow 1800 l/s
Regulating damper DRU
Technical data
Volume flow 400 l/s Volume flow 450 l/s
Volume flow 1000 l/s Volume flow 1200 l/s
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 9/38
LindabDamper ®
39
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Regulating dampers TDRU/PSDRU
The TDRU damper consists o f a cleaning hatch, KCU, a fitteddamper blade and a Tee-piece, TCPU, in whose branch thecleaning hatch can be fitted with precision.The PSDRU is like the TDRU above, but has a PSU for externalfitting. This means that the damper can be easily built into anexisting duct system.
Inspection and c leaning of the ventilation system is very easybecause the damper and cleaning hatch can be removedquickly, and there is no change in the regulation of the system,as the damper blade and cleaning hatch retain their initialsetting. Connections to the TDRU are equipped with LindabSafe sealing strips.
TDRU
Description Dimensions
∅d1∅d
3L H kg
nom mm mm
100 100 160 155 1.1
125 125 200 175 1.5
160 160 245 195 2.2
200 200 330 215 2.9
250 250 350 260 4.4
315 315 465 290 6.4
OrderingProduct code: TDRU - aaa
Type
∅d1
PSDRU
140
∅d3
∅d1
H
L
100
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 10/38
LindabDamper ®
Right to alterations reserved.
310
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
DSU is a closing damper for use where complete closure of theair flow is not required. The damper cup has marks which showthe position of the damper blade from 0-90°. The damper bladecan also be locked in position with screws.The damper cup allows for up to 50 mm of insulating material.
50
∅d1
100
DSU
Description
OrderingProduct code: DSU - aaa
Type
∅d1
Dimensions
Closing dampers, sealed
∅
d1 kgnom
63 0.4
80 0.4
100 0.5
112 0.6
125 0.6
140 0.7
150 0.7
160 0.8
180 1.0
200 1.1
224 1.2
250 1.5
280 1.7
300 1.7
315 2.0
355 2.2
400 2.7
450 3.3
500 3.8
560 4.3
600 5.1
630 5.8
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 11/38
LindabDamper ®
311
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
DTU is a closing damper for use where complete closure of theair flow is required.The damper blade is a double plate equipped with a sealingring made of non-ageing EPDM rubber which makes an airtightseal against the side.The damper cup has marks which show the position of thedamper blade from 0-90°. The damper blade can be locked inposition with screws.The damper cup allows for up to 50 mm of insulating material.
∅d1
50
100
DTU
∅
d1 M kgnom Nm
100 1.0 0.5
112 1.0 0.6
125 1.0 0.7
140 1.0 0.7
150 1.0 0.8
160 1.0 0.9
180 1.0 1.1
200 1.0 1.2
224 1.5 1.4
250 1.5 1.8
280 2.0 2.1
300 2.0 2.3
315 2.0 2.5
355 4.0 2.8
400 6.0 3.6
450 7.0 4.2
500 8.0 4.9
560 9.0 5.9
600 10.0 6.9
630 10.0 7.8
Closing dampers, sealed
Dimensions
Description
OrderingProduct code: DTU - aaa
Type
∅d1
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 12/38
LindabDamper ®
Right to alterations reserved.
312
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
DTMU/DTWU are closing dampers for use where completeclosure of the air flow is required.The damper blade is a double plate equipped with a sealingring made of non-ageing EPDM rubber which makes an airtightgasket against the side.The damper cup allows for retrofitting of 50 mm of insulating
material.DTMU: The damper cup has a handle which allows manual,infinitely variable adjustment from 0-90°.DTWU: The damper cup is equipped with a cross-arm forfitting of 2 w ires to allow remote control.
DTWU
DTMU
∅d1
100
H
100
∅d1
H
Closing dampers, sealed
Description
OrderingProduct code: DTMU - aaa
Type
∅d1
Dimensions
Dimensions
DTMU/DTWU
DTMU DTWU
∅d1
H kgnom
100 105 0.9
112 110 0.9
125 118 1.0
140 125 1.0
150 130 1.1
160 135 1.1
180 145 1.3
200 155 1.4
224 165 1.6
250 180 1.9
280 195 2.2
300 205 2.4
315 215 2.6
355 240 3.1
400 260 3.9
450 285 4.5
500 310 5.2
560 340 6.2
600 360 7.2
630 375 8.1
DTMU/DTWU
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 13/38
LindabDamper ®
313
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
TATU
3 0
6 090
Bypass dampers TATU/TASU
Description
Dimensions
70
∅d3
∅d1
L3
L
Technical data
TASU
∅d1∅d
3L L
3TASU TATU
nom mm mm kg kg
100 100 280 65 1.1 1.2
125 125 345 83 1.5 1.7
160 160 385 105 2.0 2.3
200 200 425 125 2.7 3.1
250 250 520 150 3.8 4.4
315 315 585 182 5.7 6.6
400 400 645 225 8.2 9.6
The bypass damper replaces 2 standard dampers with coup-lings and a Tee-piece.
TATUBypass damper for manual operation. Also available as TASU
without seal on the damper blade.
1000
500
200
100
50
5 10 20 50 100 200 500 1000 [ (l/s)/m ]2
[Pa]Type 4 Type 3 Type 2
Air leakage factor
P r e s s u
r e
d r o p
∆ p t
1000
500
200
100
50
5 10 20 50 100 200 500 1000 [ (l/s)/m ]2
[Pa]Type 4 Type 3 Type 2
Air leakage factor
P r e s s u r e
d r o p
∆ p t
Ordering:Product code: TATU - aaa - bbb
Type
∅d1
∅d3
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 14/38
LindabDamper ®
Right to alterations reserved.
314
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
TATBUBypass dampers
The bypass damper replaces 2 standard dampers with coup-lings and a Tee-piece.
TATBUBypass damper with motor fitted. For motor selection, see
pages 18-21.
Description
Dimensions
Technical data
105
∅d3
∅d1
L3
L
∅d1∅d
3L L
3nom mm mm kg
100 100 280 65 2.1125 125 345 83 2.6
160 160 385 105 3.2
200 200 425 125 4.0
250 250 520 150 5.4
315 315 585 182 7.5
400 400 645 225 10.5
1000
500
200
100
50
5 10 20 50 100 200 500 1000 [ (l/s)/m ]2
[Pa]Type 4 Type 3 Type 2
Air leakage factor
P r e s s u r e
d r o p
∆ p t
Ordering:Product code: TATBU - aaa - bbb
Type
∅d1
∅d3
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 15/38
LindabDamper ®
315
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
OrderingProduct code: DTBU - aaa - bbb
Type
∅d1
Motor type
150
107
100
90
∅d1
Motorised dampers DTBU 100 - 315
Description
This damper is available in all dimensions from ∅100 to ∅315,including intermediate sizes, with motor fitted for either 220Vor 24V alternating current.The motor is a reversible on/off motor controlled via a 1-poleswitch. The motor has overload protect ion and stops auto-matically when the damper reaches the end stop.The motor is fitted at a distance from the damper which allowsfor a possible 50 mm of insulating material.For motor specifications, see damper motors, page 18.
Dimensions
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 16/38
LindabDamper ®
Right to alterations reserved.
316
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
This damper is available in all dimensions from ∅355 to ∅630,including intermediate sizes, with motor fitted for either 220Vor 24V alternating or direct current. The motor is a reversibleon/of f motor cont rolled via a 1-pole switch or relay. The motorhas overload protection.The damper shaft and motor shaft can be disengaged bymeans of a release button on the motor shield. If fitted outdoors,the motor should be protected against direct UV radiation andrain. The motor is fitted at a distance from the damper whichallows for a possible 50 mm of insulating material.For motor specifications, see damper motors, page 19.
210120
128
∅d1
100
Motorised dampers DTBU 355 - 630
Description
OrderingProduct code: DTBU - aaa - bbb
Type
∅d1
Motor type
Dimensions
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 17/38
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 18/38
LindabDamper ®
Right to alterations reserved.
318
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Damper motors KM 24/220
Technical data
1 2 3 KM 220
a
220 V ~N L
1
The motorised damperopens when the switchis closed
The motorised damperopens when the switchis closed
24 V ~
a
1 2 3 KM 24
KM24 KM220
Operating voltage 24 V~ ± 20% 50 - 60 Hz 220 V ~ ± 10% 50 - 60 Hz240 V ~ ± 10% 50 Hz
Power consumption 2W 2W
Ampage 5A 12A
Connection Clamps Clamps
Turning angle Adjustable 0...100° Adjustable 0...100°
Torque at 2 Nm 2 Nmrated voltage
Scale 0..90° 0..90°
Turning time 20 to 35 s (0 to 2 Nm) 20 to 35 s (0 to 2 Nm)Shielding class IP 40 IP 40
Insulation class III (low safety voltage I (earthed)
Ambient temperature - 20°C to + 50°C - 20°C to + 50°C
Radio interference limit K K
Sound level Max. 45 dB (A) Max. 45 dB (A)
Maintenance None None
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 19/38
LindabDamper ®
319
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Damper motors SM 24/220
Technical data
SM 220
1 2 3Wire designation
220 V ~ N L
1
Parallel operation of severalmotors is possible.
SM 24
24 V ~(-) (+)
1 2 3Wire designation
SM24 SM220
Operating voltage 24 V ~ ± 20% 50 - 60 Hz 220 V ~ ± 10% 50 - 60 Hz24 V - ± 10%
Power consumption 1.5W 8W
Ampage 4A 10A
Connection Cable Cable
Turning angle 95° (mech. restricted) 95° (mech. restricted)
Torque at 15 Nm 15 Nm (50Hz)rated voltage 10 Nm (60Hz)
Scale 0 to 10 (0 = start ) 0 to 10 (0 = start )
Turning time 90 to 150 s (0 to 15 Nm) Approx. 80 s
Shielding class IP 42 IP 42
Insulation class III (low safety voltage) I (earthed)
Ambient temperature - 20°C to + 50°C - 20°C to + 50°C
Radio interference limit VDE 0875, part 1 (11.84) VDE 0875, part 1 (11.84)
Sound level Max. 45 dB (A) Max. 45 dB (A)
Maintenance None None
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 20/38
LindabDamper ®
Right to alterations reserved.
320
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Damper motors SF 24/230
Technical data
SF 24 / SF 230
1 2
(-) (+) (24 V ~)N L
1(230 V ~)
SF24 SF230
Operating voltage 24 V ~ ± 20% 50 - 60 Hz 220 - 240 V ~ ± 10% 50 - 60 Hz24 V - ± 10%
Power consumption Max. 5.5W Max. 8W
Ampage 7.5A 10VA
Connection Cable Cable
Turning angle 90° (mech. restricted) 90° (mech. restricted)
Torque- motor Min. 15 Nm Min. 15 Nm- spring Min. 15 Nm Min. 15 Nm
Scale 0 to 1 0 to 1
Turning time
- spring stressing- motor Approx. 110 s Approx. 110 s- spring return Approx. 10 s Approx. 10 s
Shielding class IP 42 IP 42
Insulation class I (earthed) I (earthed)
Ambient temperature - 30°C to + 50°C - 30°C to + 50°C
Radio interference limit VDE 0875 part 1 VDE 0875 part 1A1 (10.86) A1 (10.86)
Sound level Max. 45 dB (A) Max. 45 dB (A)
Maintenance None None
Service life Approx. 60 000 operations Approx. 60 000 operations
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 21/38
LindabDamper ®
321
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Damper motors FM 24 - SR
Technical data 24 V ~ ~
T
Y1 0...10 V -
Y2 0...20 V
Phase section
~ Y1 Y2 U FM 24-SR T
U 2...10 V -
Wire designation
FM 24 - SR
Operating voltage 24 V ~ ± 20 % 50...60 Hz
Power consumption 6W
Ampage 15A
Connection Cable
Control signal Control signal Y1 0 - 10V- / Y
2 0 - 20V phase section
Input resistance 100 K Ω ( 0,1mA ) / 8 K Ω ( 50mW )Operating range 2 - 10 V - / 2 - 10 V phase section
Tracking ± 5%
Measuring voltage U 2 to 10 V - ( max. 0,5 mA)for 0 to 100%
Turning angle 90° (mechanically restricted)
Torque- motor Min. 10 Nm- spring Min. 10 Nm
Scale 0 to 1
Turning time- spring stressing Approx. 200 s- motor 100 to 200 s ( 0 to 10 Nm )- spring return Approx. 40 s
Shielding class IP 42
Insulation class III (low safety voltage)
Ambient temperature - 20° C to + 50° C
Radio interference suppression VDE 0875, part 1 ( 11.84 )
Sound level Max. 45 dB (A)
Maintenance None
Service life- spring Approx. 2000 activations
1 2 3 4 5
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 22/38
LindabDamper ®
Right to alterations reserved.
322
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Extension wrench VFFits all standard damper handles
Damper arm A15Fits onto extension wrench VF
L
∅8∅19
15 8
110
Accessories for motorised dampers
Dimensions
Dimensions
Dimensions
Spring-action coupling rodFK 500/8 FK 1000/8Type FK 500/8 L = 500 mmType FK 1000/8 L = 1000 mm
20
60
∅15
45
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 23/38
LindabDamper ®
323
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Ball swivel joint RK 8Fits on damper arm A15and coupling rod FK.
∅13
45
∅8,3
Accessories for motorised dampers
Dimensions
Installation example:• Extension wrench, VF• Damper arm, A15• Spring-action coupling rod, FK 500/8• Ball swivel joint, RK 8
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 24/38
LindabDamper ®
Right to alterations reserved.
324
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
The iris damper type IBU is designed for regulation and mea-surement of the volume flow in ventilation systems. The specialiris design provides accurate regulation, smooth flow and lownoise level.
IBU as a volume flowmeasuring deviceThe iris damper enables the user to measure the volume flowquickly and accurately. The accurate contro l mechanism gua-rantees precise opening of the damper in relation to the scale.The damper is equipped with two outputs (to be connected toa manometer) for measuring the differential pressure, whichcan be directly converted to volume flow by means of the dia-grams.The iris damper is a permanent measuring station and thecontrol measurements can be taken very quickly at all times.Each damper is calibrated individually, giving accurate mea-suring results, with the method error being ±7%.
IBU as a regulation damperThe round, adjustable aperture in the iris damper allows re-gulation of the volume flow with a smooth flow profile and arelatively low noise level. Regulation is easy and fast, and theeffect of the regulation is immediate.
Design and materialsIBU is designed in galvanised plate and equipped w ith a scaleand measurement output. The connections are fitted with Lin-dabSafe sealing strips.
Iris damper IBU
Description
OrderingProduct code: IBU - aaa
Type
∅d1
Dimensions
∅6
20
∅d1
∅D
L
∅d1
∅D L kg
nom80 125 50 0.5
100 165 50 0.6
125 210 50 0.9
150 230 55 1.1
160 230 55 1.2
200 285 55 1.7
250 335 55 2.3
300 410 160 4.2
315 410 55 3.7
400 525 70 6.7
500 655 70 9.8
630 815 70 15.8
800 1015 70 25.0
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 25/38
LindabDamper ®
325
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Technical data
Iris damper IBU
Volume flow qv
Quick selection guide Size
m /h318000100005000200010006003002001006040
10 20 40 60 100 200 300 500 1000 2000 5000 l/s
800630
500400
300/315250
200160
150125
10080
v (m/s)2 4 6 8
300
200
100
6050
40
30
20
6 7 10 20 30 60 100 140
20 40 60 100 200 300 500
2
1
4
3
567
50
45
40
30 dB(A)
Lp 10A
10
3525
40
5030
8
(l/s)
(m /h)3
P r e s s u r e
d r o p
p
( P a )
t
Volume flow qv
IBU 100
300
200
100
6050
40
30
20
3 4 5 10 20 30 40 70 (l/s)
10 20 30 40 5060 100 200 250
45
(m /h)3
2
1
4
3
567
P r e s s u r e
d r o p
p
( P a )
t
40
35
30
25 dB(A)Lp 10A
10
Volume flow qv
IBU 80
300
200
100
6050
40
30
20
10 20 30 40 100 200
40 60 100 200 300 400 700
1
4
2
56
55
45
40
30 dB(A)
Lp 10A
10
35
25
60
50
7 3
50
(l/s)
(m /h)3
P r e s s u r e
d r o p
p
( P a )
t
Volume flow qv
IBU 125
300
200
100
6050
40
30
20
15 20 30 40 200 300
60 100 200 300 400 600 1000
2
4
3
58
50
45
55 dB(A)
Lp 10A10
25
100
70
7 6
1
40
30 35
(l/s)
(m /h)3
P r e s s u r e
d r o p
p
( P a )
t
Volume flow qv
IBU 150
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 26/38
LindabDamper ®
Right to alterations reserved.
326
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
300
200
100
6050
40
30
20
80 100 200 1000 1500
300 400500 1000 2000 5000
1
48
50
40 dB(A)Lp 10A
10500
7 6
302535
55
300
2
45
5 3
60
3000
(l/s)
(m /h)3
P r e s s u r e
d r o p
p
( P a )
t
Volume flow qv
IBU 300/315
300
200
100
6050
40
30
20
100 300 2000
400 600 1000 2000 9000
1
48
50
65 dB(A)
Lp 10A10
1000
7 6
3025 35
55
500
2
45
5
60
3000
3
40
200
5000
(l/s)
(m /h)3
P r e s s u r e
d r o p
p
( P a )
t
Volume flow qv
IBU 400
300
200
100
6050
40
30
20
50 60 100 400 700
200 300 400 500 1000 2000 2500
2
3
58
50
45 dB(A)Lp 10A
10300
7 6
1
3025 35
55
200
4
60
40(l/s)
(m /h)3
P r e s s u r e
d r o p
p
( P a )
t
Volume flow qv
IBU 250
300
200
100
6050
40
30
20
30 40 60 300 500
100 200 300 400 600 1000 1800
2
4
3
58
50
45
40 dB(A)
Lp 10A
10200
7 6
1
3025 35
55
100 (l/s)
(m /h)3
P r e s s u r e
d r o p
p
( P a )
t
Volume flow qv
IBU 200
300
200
100
6050
40
30
20
15 20 30 40 200 300
60 100 200 300 400 600 1000
2
4
3
58
50
45
40 dB(A)
Lp 10A
10100
70
7 6
1
30
25 35
55
60 (l/s)
(m /h)3
P r e s s u r e
d r o p
p
( P a )
t
Volume flow qv
IBU 160
Sizing guide
Iris damper IBU
Technical data
300
200
100
6050
40
30
20
200 500 4000
700 1000 2000 3000 14000
1
48
50Lp 10A
102000
7 6
3025 35
55
1000
2
45
5
65 dB(A)
5000
3
40
300
10000
60
(l/s)
(m /h)3
P r e s s u r e
d r o p
p
( P a )
t
Volume flow q v
IBU 500
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 27/38
LindabDamper ®
327
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Iris damper IBU
Technical dataSizing guide
300
200
100
6050
40
30
20
500 10000
2000 3000 5000 10000 30000
48
102000
7 6
1000
1
5
20000
3
5000
2
65 dB(A)
60
55
50
Lp 10A25 30 35 40 45
(l/s)
(m /h)3
P r e s s u r e
d r o p
p
( P a )
t
Volume flow qv
IBU 800
300
200
100
6050
40
30
20
300 500 6000
1000 2000 3000 5000 20000
1
48
102000
7 6
1000
2
5
65 dB(A)
10000
3
400 3000
50Lp 10A
3025 3555
40
60
45
P r e s s u r e
d r o p
p
( P a )
t
Volume flow qv
IBU 630
(l/s)
(m /h)3
Correction KOKt
(dB)
Frequency (Hz)∅d 125 250 500 1000 2000 4000 8000
80 13 9 7 3 -2 -6 -23100 15 13 7 1 -5 -13 -22
125 12 11 6 1 -8 -15 -25
150 20 14 6 -2 -8 -18 -22
160 14 8 3 -1 -4 -14 -22
200 11 9 4 -1 -8 -14 -21
250 10 5 1 1 -9 -14 -21
300 6 5 0 0 -5 -10 -19
315 6 5 0 0 -5 -10 -19
400 4 4 1 -1 -4 -9 -13
500 3 3 1 -1 -4 -8 -11
630 4 2 2 -1 -5 -9 -11
800 3 2 3 -1 -6 -10 -13
Tol.± 3 2 2 2 2 2 3
LW okt = Lp 10A + KOKt
Lp 10A can be read off the diagrams
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 28/38
LindabDamper ®
Right to alterations reserved.
328
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
D
≥ 4D ≥ 1D
D
> 2D
D
d
> 4D
D 1D
D
1D
D
d
1d
D
≥ 2D
D
≥ 2D
> 2D
DD
Iris damper IBU
Technical data
In duct
Tee
After Tee-branch
Reduction
Expansion In connection with air supply device
90° Elbow
Before Tee-branch
Tee
Minimum installation dimensions
≥ 4D
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 29/38
LindabDamper ®
329
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
500
300
200
100
50
20
15 (l/s)
5
10
8 7
1
6 4
40
30
60 100 200 3004030
3
2
20
Volume flow qv
IBU 150
P r e s
s u r e
d i f f e r e n c e
p
( P a )
60 100 200 300 400 600 100070 (m /h)3
500
300
200
100
50
20
15 (l/s)
5
10
8 7
1
6 4
40
30
60 100 200 3004030
3
2
20
Volume flow qv
IBU 160
P r e s s u r e
d i f f e r e n c e
p
( P a )
60 100 200 300 400 600 100070 (m /h)3
500
300
200
100
50
20
30 (l/s)
5
10
8 7
1
6 4
40
30
100 200 300 5007050
2
40
3
Volume flow qv
IBU 200
P r e s s u r e
d i f f e r e n c e
p
( P a )
100 200 300 400 600 1000 1800 (m /h)3
500
300
200
100
50
20
10 (l/s)
4
10
7 6
1
5 3
40
30
40 60 100 2003020
8
2
Volume flow qv
IBU 125
P r e s s u r e
d i f f e r e n c e
p
( P a )
40 60 100 200 300 400 70050 (m /h)3
500
300
200
100
50
20
6 (l/s)
4
10
7 6
7
1
5
2
3
40
30
30 40 60 100 140
8
2010
Volume flow qv
IBU 100
P r e s s u r e
d i f f e r e n c e
p
( P a )
20 40 60 100 200 300 5005030 (m /h)3
500
300
200
100
50
20
3 (l/s)
4
10
7 6
4
1
5
2
3
40
30
5 10 20 30 40 70
P r e s s u r e
d i f f e r e n c e
p
( P a )
Volume flow qv
IBU 80
10 20 30 40 50 60 100 200 250 (m /h)3
Measuring and regulation
Iris damper IBU
Technical data
P r e s s u r e
d i f f e r e n c e
∆ p t
( P a )
P r e s s u r e
d i f f e r e n c e
∆ p t
( P a )
P r e s s u r e
d i f f e r e n c e
∆ p t
( P a )
P r e s s u r e
d i f f e r e n c e
∆ p t
( P a )
P r e s
s u r e
d i f f e r e n c e
∆ p t
( P a )
P r e s
s u r e
d i f f e r e n c e
∆ p t
( P a )
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 30/38
LindabDamper ®
Right to alterations reserved.
330
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
500
300
200
100
50
20
(l/s)
4
10
7 6 5 3
40
30
300 1000 2000 4000
1
500200
2
400
8
Volume flow qv
IBU 500
P r e s s u r e
d i f f e r e n c e
p
( P a )
700 1000 2000 3000 140005000 10000 (m /h)3
500
300
200
100
50
20
(l/s)
4
10
7 6 5 3
40
30
1000 2000 6000
1
500300
400
8
2
Volume flow qv
IBU 630
P r e s s u r e
d i f f e r e n c e
p
( P a )
1000 2000 3000 5000 2000010000 (m /h)3
500
300
200
100
50
20
(l/s)
4
10
7 6 5 3
40
30
2000 5000 10000
1
1000500
400
8 2
Volume flow qv
IBU 800
P r e s s u r e
d i f f e r e n c e
p
( P a )
2000 3000 5000 10000 3000020000 (m /h)3
500
300
200
100
50
20
(l/s)
4
10
7 6 5 3
40
30
200 500 1000 2000
1
300100
2
400
8
Volume flow qv
IBU 400
P r e s s u r e
d i f f e r e n c e
p
( P a )
400 600 1000 2000 90003000 5000 (m /h)3
500
300
200
100
50
20
(l/s)
5
10
8 7
1
6 4
40
30
200 500 1000 1500100
2
30080
3
Volume flow qv
IBU 300/315
P r e s s u r e
d i f f e r e n c e
p
( P a )
300 400500 1000 2000 50003000 (m /h)3
500
300
200
100
50
20
(l/s)
5
10
8 7
1
6 4
40
30
100 300 400 70060
2
3
20050
Volume flow qv
IBU 250
P r e s
s u r e
d i f f e r e n c e
p
( P a )
200 300 400 500 1000 2000 2500(m /h)3
Iris damper IBU
Technical dataMeasuring and regulation
P r e s
s u r e
d i f f e r e n c e
∆ p t
( P a )
P r e s
s u r e
d i f f e r e n c e
∆ p t
( P a )
P r e s s u r e
d i f f e r e n c e
∆ p t
( P a )
P r e s s u r e
d i f f e r e n c e
∆ p t
( P a )
P r e s s u r e
d i f f e r e n c e
∆ p t
( P a )
P r e s s u r e
d i f f e r e n c e
∆ p t
( P a )
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 31/38
LindabDamper ®
331
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
OrderingProduct code: FMU - aaa
Type
∅d1
FMU is a measuring device designed for stationary installa-tion. By measuring the pressure drop across the measuringoutputs, the volume flow can be read off the gauge diagram.The flow meter, which is available in the sizes ∅80 - ∅630 mm,is prepared for up to 100 mm insulation. Installing the flowmeter does not restrict cleaning of the duct. FMU is supplied
with LindabSafe seals.
Advantages of FMU Relatively low total pressure drop Relatively low noise level Prepared for insulation 100 mm Easy to combine with other components Does not prevent duct cleaning
Flow meter FMU/FMDRU
Description
Dimensions
FMU∅
d1∅
di L kgnom
80 63 110 0,4
100 80 100 0,5
125 100 120 0,5
160 125 120 0,5
200 160 125 0,7
250 200 145 1,3
315 250 210 1,5
400 315 220 2,7
500 400 265 4,2
630 500 355 5,6
FMDRU for regulationCombining the flow meter with the DRU regulator damper, en-
ables the user to regulate the volume flow.
FMU
∅d1
L
∅di
FMDRU
FMDRU∅d1
∅di
L1
kgnom
80 63 300 0,9
100 80 290 1,1
125 100 310 1,2
160 125 315 1,3
200 160 380 2,1
250 200 440 3,3
315 250 570 4,3
400 315 660 7,8
500 400 840 12,3
630 500 1030 17,0
L1
∅d1
Flow
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 32/38
LindabDamper ®
Right to alterations reserved.
332
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
63050040031525020016012510080
[m3 /h]
10
50
100
300
10 50 100 500 1000 5000 [l/s]
50 100 500 1000 5000 10000200 2000
200
40
30
20
Flow meter FMU
Technical dataPressure drop diagramfor FMU selectionThe dot ted curves indicate the pressure drop, ∆ pt, across themeasuring output as a funct ion of the volume flow, q. The so-lid curves indicate the A-weighted sound power level, LW(A), indB for the duct . Note: Pressure drop data for regulation deviatefrom this diagram.
Regulation diagramThe curves indicate the volume flow, q, as a function of thepressure drop across the measuring output.
Measuring method for soundSound generation is measured by the National Swedish Institutefor Materials Testing (Statens Provningsanstalt) in a rever-beration room in accordance with ISO 5135 and ISO 3741, andindicates the A-weighted sound power level, LWA, for the duct.(For informat ion on frequency d istribution, see page 34).
Note: Pressure drop data for dimensioning deviate from thisdiagram.
Alternatively, the volume flow can be calculated on the basis ofthe following formulae:
∅d = 80 q = 4,78 X ∆ pt , I/s
∅d = 100 q = 7,32 X ∆ pt , I/s
∅d = 125 q = 11,2 X ∆ pt , I/s
∅d = 160 q = 18,0 X ∆ pt , I/s
∅d = 200 q = 31,6 X ∆ pt , I/s
∅d = 250 q = 48,5 X ∆ pt , I/s
∅d = 315 q = 73,3 X ∆ pt , I/s
∅d = 400 q = 112,0 X ∆ pt , I/s
∅d = 500 q = 191,0 X ∆ pt , I/s
∅d = 630 q = 283,0 X ∆ pt , I/s
∆ pt in Pa
[ Pa ] Measuring output Dimensions [mm]
P r e s s u r e
d r o p
∆ p t
Volume flow q
50
40
30
60
m3 /h
1
5
10
50
100
10 50 100 500 1000 5000 l/s
50 100 500 1 000 5 000 10 000
80 100 125 160 200 250 315 400
630
500
[ Pa ] Dimensions [mm]
Sound powerlevel
LWA [dB]
P r e s s u r e
d r o p
∆ P
t
Volume flow q
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 33/38
LindabDamper ®
333
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Methoderror
Examples of duct layout m2 = 5%
2 x d1
90 ° bend
1 x d1
Two 90 ° bends
in the same plan
1 x d1
Two 90 ° bends
in planes at right angles
4 x d1
A revolving damp er (45 ° ). The shaf t
is in l ine with the measuring outputs.
Flow meter FMU
Technical dataMeasuring accuracyThe minimum required length for a straight duct sectionbefore
the flow meter in order to limit method errors to 5% is specifiedin the table.
A straight duct sect ion of 1 x d is required after the flow meter.d1 indicates the nominal diameter of the duct.
∅ d 1
S
S
∅ d 1
S
S
∅d1
∅ d 1
S = straight duct section before flow meter
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 34/38
LindabDamper ®
Right to alterations reserved.
334
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
Flow meter FMU
Technical dataSound data for FMU
Velocity approx. 5 m/s Velocity approx. 10 m/s Velocity approx. 15 m/s
dim Frequency Hz Frequency Hz Frequency Hz∅d
163 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
Volume flow 25 I/s Volume flow 50 I/s Volume flow 75 I/s
80 49 45 42 33 22 14 11 11 54 56 56 51 42 34 29 21 68 62 61 59 54 44 41 34
Volume flow 40 I/s Volume flow 80 I/s Volume flow 120 I/s
100 50 45 39 30 18 6 2 7 51 58 54 48 38 30 22 18 60 64 62 59 50 43 38 34
Volume flow 60 I/s Volume flow 120 I/s Volume flow 180 I/s
125 45 40 33 24 11 1 1 8 53 55 50 42 34 26 21 16 61 62 61 53 45 38 35 33
Volume flow 100 I/s Volume flow 200 I/s Volume flow 300 I/s
160 41 39 31 24 13 0 0 3 58 54 50 42 34 27 19 15 66 64 61 52 46 41 35 31
Volume flow 150 I/s Volume flow 300 I/s Volume flow 450 I/s
200 41 36 32 23 7 0 0 4 55 52 47 39 30 23 20 17 64 62 58 48 42 38 34 31
Volume flow 250 I/s Volume flow 500 I/s Volume flow 750 I/s
250 44 37 31 22 17 15 17 17 64 53 48 39 28 27 26 22 72 64 58 49 44 40 39 29
Volume flow 400 I/s Volume flow 800 I/s Volume flow 1200 I/s
315 51 35 29 19 14 10 5 6 64 55 46 38 34 31 32 28 72 65 57 48 45 42 42 41
Volume flow 600 I/s Volume flow 1200 I/s Volume flow 1800 I/s
400 46 37 30 22 19 14 9 7 61 55 47 40 36 34 33 29 72 65 57 50 47 45 44 43
Volume flow 1000 I/s Volume flow 2000 I/s Volume flow 3000 I/s
500 50 40 29 24 22 15 8 5 64 58 47 41 40 40 37 30 75 69 59 53 51 52 51 46
Volume flow 1500 I/s Volume flow 3000 I/s Volume flow 4500 I/s
630 53 43 32 28 25 19 14 10 68 61 50 44 43 45 42 35 78 73 62 56 54 58 57 48
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 35/38
LindabDamper ®
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
335
Flow meter
Technical dataSound data for FMDRU regulating damper
dim Pressure Velocity approx. 5 m/s Velocity approx. 10 m/s Velocity approx. 15 m/s∅d
1drop
(Pa) Frequency Hz Frequency Hz Frequency Hz63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
500 64 65 62 59 57 56 52 51 68 76 76 70 64 61 59 56 71 80 80 73 67 63 61 58
300 61 62 58 55 52 50 45 43 65 75 75 67 61 57 53 49 68 79 77 68 63 58 55 52
80 200 59 60 56 51 47 46 40 38 63 75 74 64 58 53 48 44 67 78 75 64 59 54 51 47100 56 56 51 45 40 38 30 28 59 74 72 59 52 47 40 35 63 76 71 58 53 48 42 38
50 52 52 47 40 33 30 21 18 56 73 71 54 47 41 32 26 Pressure drop exceeds 50 Pa
500 64 63 62 58 56 55 53 54 67 76 76 69 63 60 61 61 70 81 82 70 66 64 64 64
300 61 60 58 54 51 50 46 46 65 76 76 65 59 55 56 56 68 81 80 65 62 60 60 59
100 200 59 58 55 51 47 46 40 40 62 75 75 62 55 51 52 53 65 81 79 61 58 57 56 55100 56 54 51 45 40 40 31 30 59 75 75 57 49 44 46 46 62 81 78 54 52 51 50 49
50 52 50 46 39 34 33 22 20 55 75 74 52 43 37 39 40 Pressure drop exceeds 50 Pa
500 66 64 62 59 56 56 54 53 72 76 75 68 63 60 61 59 75 81 79 71 66 63 63 61
300 63 61 58 55 51 51 47 45 69 75 73 65 59 56 55 53 73 79 76 67 62 59 58 56
125 200 61 59 56 51 47 47 42 40 67 74 71 62 56 52 50 49 71 78 74 63 58 55 53 51100 57 55 51 46 41 40 33 30 64 72 69 57 50 45 43 41 67 76 70 57 52 49 46 43
50 53 51 46 40 35 32 25 21 60 71 66 51 44 38 36 34 Pressure drop exceeds 50 Pa
500 66 63 61 57 54 54 53 52 77 78 73 67 63 59 59 58 80 81 76 71 66 62 61 59
300 63 60 57 53 50 49 47 45 75 77 70 63 59 54 54 53 78 79 72 67 62 57 55 53
160 200 61 58 55 50 47 45 42 40 74 75 68 60 56 50 49 48 76 77 69 64 58 53 50 48100 58 54 50 45 41 38 34 31 71 73 64 55 51 43 42 41 74 74 63 59 53 46 42 3950 55 51 45 39 36 31 26 23 69 71 60 50 46 36 34 33 71 71 58 54 47 39 34 31
500 71 68 65 61 58 58 57 55 77 78 74 68 64 62 63 61 80 82 78 71 67 65 66 63300 67 64 60 57 53 53 50 47 74 75 71 64 60 57 57 55 77 79 74 67 63 60 60 57
200 200 65 61 57 53 49 49 45 42 71 73 68 61 56 53 52 50 74 77 71 63 58 56 55 52100 60 56 52 48 43 41 36 32 66 69 64 55 50 46 45 42 70 71 66 57 52 50 48 44
50 55 52 46 42 37 34 28 23 62 66 60 50 44 38 37 34 65 69 51 50 46 41 40 35
500 69 66 64 61 57 59 58 56 79 76 72 67 62 61 64 63 83 81 76 72 65 64 67 66
300 66 63 60 58 53 54 53 49 77 73 68 63 57 56 59 58 81 77 72 68 60 59 61 60
250 200 64 60 57 55 49 50 49 44 75 70 65 60 53 52 54 53 78 74 69 65 56 55 57 55100 60 56 52 50 43 44 41 34 72 65 59 54 47 45 47 46 75 69 63 60 50 48 50 47
50 56 51 47 45 37 37 34 25 69 61 54 49 40 38 39 38 71 64 58 55 43 41 42 39
500 76 71 67 62 60 60 60 57 82 79 74 68 66 64 65 63 86 83 77 71 68 66 69 64
300 72 67 62 58 55 55 54 49 78 75 69 64 61 58 59 57 82 79 72 66 63 61 62 58
315 200 69 64 59 55 51 50 48 44 74 72 66 60 57 54 54 51 78 75 69 62 59 56 57 53100 63 58 53 49 45 43 39 34 69 66 60 54 51 46 46 43 73 67 62 56 52 51 49 44
50 58 52 47 43 39 36 30 24 63 61 54 48 44 38 38 34 67 64 56 49 45 41 41 36
500 78 71 66 61 58 59 59 55 83 78 72 67 65 64 65 62 88 82 76 71 68 67 68 64300 73 67 61 57 54 54 53 48 77 73 67 62 60 59 59 56 84 78 71 66 64 62 63 58
400 200 69 63 58 54 51 50 48 43 73 69 63 58 56 54 54 51 80 74 67 63 60 58 59 53100 63 56 51 48 45 43 39 34 65 62 56 52 50 47 46 42 74 68 60 56 54 50 52 45
50 56 50 45 43 40 36 31 25 58 55 49 45 43 39 38 34 68 62 54 50 48 43 45 37
500 81 75 69 64 61 63 63 59 87 81 73 68 67 66 67 64 91 84 76 71 69 68 72 66300 76 70 64 60 57 57 57 51 82 75 67 63 62 60 61 58 86 79 70 66 64 62 64 59
500 200 73 66 61 57 54 52 51 45 78 71 63 59 57 55 56 53 82 74 66 62 59 57 59 54
100 66 59 53 51 48 45 42 35 71 64 55 53 51 47 47 44 75 62 58 55 52 52 51 4550 60 53 47 45 42 37 33 26 65 56 48 46 44 38 39 35 69 60 51 49 45 40 43 36
500 88 81 74 68 66 67 67 62 91 84 75 70 70 69 70 66 93 86 77 71 71 70 76 67300 82 75 68 63 61 60 60 54 85 78 69 65 65 62 63 59 87 80 71 65 65 63 65 60
630 200 78 71 64 59 57 55 54 47 80 73 64 61 60 57 58 53 82 75 66 60 60 57 60 54
100 70 63 56 53 51 46 43 36 72 65 56 54 53 48 48 43 73 67 58 52 51 48 51 4450 63 56 49 46 44 38 33 25 64 57 48 47 46 39 39 33 65 59 50 44 43 38 42 34
Volume flow 25 l/s Volume flow 50 l/s Volume flow 75 l/s
Volume flow 60 l/s Volume flow 120 l/s Volume flow 180 l/s
Volume flow 100 l/s Volume flow 200 l/s Volume flow 300 l/s
Volume flow 150 l/s Volume flow 300 l/s Volume flow 450 l/s
Volume flow 250 l/s Volume flow 500 l/s Volume flow 750 l/s
Volume flow 600 l/s Volume flow 1200 l/s Volume flow 1800l/s
Volume flow 1000 l/s Volume flow 2000 l/s Volume flow 3000 l/s
Volume flow 1500 l/s Volume flow 3000 l/s Volume flow 4500 l/s
Volume flow 400 l/s Volume flow 800 l/s Volume flow 1200 l/s
Volume flow 40 l/s Volume flow 80 l/s Volume flow 120 l/s
FMDRU
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 36/38
LindabDamper ®
Right to alterations reserved.
336
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
0
4080∅100 [Pa]
500
100
50
10
20 50 100 120 [ I/s ]
[ m3 /h ]400300200100
60
[ °]
4 0
5 0
6 0
7 0
20
Volume flow q
Sound power level
LWA
[dB ] B la de a ngle
P
r e s s u r e
d r o p
∆ p t
∅100 [Pa]
0
20
4060807 0 6 0 500
5 0
4 0
100
50
10
60 100 200 300 [ I/s ]
[ m3 /h ]1000500400300
[ °]∅160 [Pa]
Volume flow q
Sound power level
LWA
[dB ] B la de a ngle
P
r e s s u r e
d r o p
∆ p t
∅160 [Pa]
∅250 [Pa]
500
100
50
10100
500
200
1000
300 400 500
2000
800 [ I/s ]
[ m3 /h ]
4 0
5 0
6 0 7 0
20
0
406080
[ °]
Volume flow q
Sound power level
LWA
[dB ] B la de a ngle
P
r e s s u r e
d r o p
∆ p t
∅250 [Pa]
80 60 40
[ °]
20
0
[ I/s ]
[ m3 /h ]
50040030020010090
400 500 1000
10
50
100
500
4 0
5 0
6 0 7 0
∅200 [Pa]
Volume flow q
Sound power level
LWA
[dB ] B la de a ngle
P
r e s s u r e
d r o p
∆ p t
∅200 [Pa]
0
∅125 [Pa]
500
100
50
10
30 50 100 200 [ I/s ]
[ m3 /h ]500400300200
4 0
6 0
7 0
20
406080
[ °]
Volume flow q
Sound power level
LWA
[dB ] B la de a ngle
P
r e s s u r e
d r o p
∆ p t
∅125 [Pa]
80 60 40
[ °]
20
0
8 0
7 0 6
0 5 0
4 0
500
100
50
10
10 20 30 40 50 80 [ I/s ]
[ m3 /h ]20010050
∅80 [Pa]
Flow meter FMDRU
Technical dataFMDRUPressure drop diagram for selection.
The dotted curves indicate the pressure drop, ∆ pt, across the
flow meter as a funct ion of the volume flow, q. The solid curvesindicate the A-weighted sound power level, L
WA, in dB for the
duct.Note: Pressure drop data for regulation deviate from thesediagrams.
Volume flow q
Sound power level
LWA
[dB ] B la de a ngle
P
r e s s u r e
d r o p
∆ p t
∅80 [Pa]
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 37/38
LindabDamper ®
Right to alterations reserved.
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
337
0
6 0
7 0
5 0
4 0
10
50
100
50060 40
[ °]
20
[ I/s ]2000
[ m3 /h ]50004000
1000
30002000
500400
∅400 [Pa]
Volume flow q
Sound power level
LWA
[dB ] B la de a ngle
P
r e s s u r e
d r o p
∆ p t
∅400 [Pa]
∅630 [Pa]500
100
50
10
900 1000 2000 3000 4000 5000 [ I/s ]
[ m3 /h ]1000050004000
5 0
6 0
7 0
80 60 40
[ °]
20
0
Volume flow q
Sound power level
LWA
[dB ] B la de a ngle
P
r e s s u r e
d r o p
∆ p t
∅630 [Pa]
60 40500
100
50
10
300020001000600 [ I/s ]
[ m3 /h ]10000500040003000
5 0
6 0
7 0
20
0
[ °]∅500 [Pa]
Sound power level
LWA
[dB ] B la de a ng le
P
r e s s u r e
d r o p
∆ p t
∅500 [Pa]
80 60 40
[ °]
20
0
[ I/s ]
[ m3 /h ]
1000 1200
400030002000
500
1000
200
10
50
100
500
∅315 [Pa]
4 0
5 0
6 0
7 0
Volume flow q
Sound power level
LWA
[dB ] B la de a ngle
P
r e s s u r e
d r o p
∆ p t
∅315 [Pa]
Volume flow q
Flow meter FMDRU
Technical data
8/12/2019 1335449194_4451_13_VENTILATION_3 DAMPERS
http://slidepdf.com/reader/full/1335449194445113ventilation3-dampers 38/38
LindabDamper ®
338
G e n e r a
l
S a f e
S i l e n c e r
I s o l
T
r a n s f e r
F l a t o v a l
C o m f o r t
B
L
H
∅d1
Slide damper SKU
Description
The slide damper is a manual damper which can be placedwhere complete or part ial blocking off of the air flow is desired.
OrderingProductcode: SKU aaa
Dimensions
∅d1
L B H kgmm mm mm mm
80 140 140 170 0,4100 180 180 210 0,6
112 200 200 240 0,6
125 200 200 240 0,7
140 210 210 265 0,9
150 220 220 270 0,9
160 220 220 285 1,0
180 280 280 350 1,1
200 300 300 360 1,3
224 320 320 400 1,5
250 350 350 440 1,9
280 360 360 480 2,0
300 400 400 540 2,3
315 400 400 540 2,7
Recommended