12.03 Presentation

Preview:

Citation preview

/solarIVY/2.0

/solarIVY/precedent

/solarIVY/precedent

/solarIVY/research

max + min daily temp (C) with and without ivy

average temp + humidity range between ivy-covered and exposed surfaces

green wall benefits:

- can reduce ambient surround temperatures by 2 degrees (c) on average

- can reduce the U-value of a lightweight wall from 1.24 to 0.69 (W/m2) and heavyweight from 1.16 to 0.68 (W/m2)

- can reduce heat gain by up to 75%, and there-by also reduce cooling loads by 75%

/patternResearch/penrose

/materials/

/input point/1

/input point/2

/input point/3

/input point/4

/attractor point/

/attractor point/

/inner layer/

/middle layer/

/inner layer/

/input/parameters//frame size//pillow depth (ratio)

2” 30%

/input/parameters//frame size//pillow depth (ratio)

4” 30%

/input/parameters//frame size//pillow depth (ratio)

2” 30%

/input/parameters//frame size//pillow depth (ratio)

2” 10%

/output/parameters//outer panel uv area//middle panel uv area//shaded area

1.532 m2 1.115 m2 2.555 m2

/output/parameters//outer panel uv area//middle panel uv area//shaded area

2.114 m2 1.115 m2 2.555 m2

/solarIVY/penrose grid

/solarIVY/orthagonal grid

/solarIVY/analysis

/solarIVY/design map

//output/data_carbon reduction_energy produced_cost savings_tree equivalent

//user input/geometry_four points/grid_attractor point/

//user input/parameters_grid divisions_frame size/inches_pillow depth/ratio_overshading factor/_pv divisions/_orientation/_tilt/angle

coefficients:

SC /cost savings/ = kWp x 260

CC /carbon reudction/ = kWp x 950

TC /tree equivalent/ = kWp x 2.55

capacity /kWp/

CIGS /w per m2/ = 387.5 w/m2

Area /m2/ = variable (x)

/solarIVY/formulas

output /kWh/ = 0.8 x kWp x S x Zpv x Ct

where:kWp = installed solar peak powerS = annual solar radiation Zpv = overshading factorCt = tilt angle of collector / 100

/solarIVY/formulas

//overshading factor/

//solar radiation/nyc

/output/parameters.annual//carbon reduction//energy produced//cost savings//tree equivalent

/input/parameters//overshading: significant//orientation: south//tilt: 90 deg

54,915 lbs 5,261 kWh $15,093 147 trees

/solarIVY/wall

/solarIVY/arbor

Recommended