Reviewed For Code Compliance
1. Must meet TIA 2222. Need sealed 3rd party inspection report for thecell tower upgrade at the final inspection.ART 7.6.2016
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
February 22, 2016
TowerCom
Re: Proposed 150-ft Pine Tree MonopoleLocated in Brunswick Co., NC: Sunset Harbor SiteMFP #23513-784 / TAPP 15-2019 TP-13942
I understand that there may be some concern on the part of local building officials regarding the potentialfor failure of the proposed communication monopole. Communication structures are designed inaccordance with the Telecommunications Industry Association ANSI/TIA-222-G, "Structural Standards forSteel Antenna Towers and Antenna Supporting Structures". This structure is to be fabricated byTransAmerican Power Products.
I have designed this monopole for (4) four antenna carrier levels, and to withstand a 3-second gusted windspeed of 140 mph (Vasd) as recommended by ANSI/TIA-222-G for Brunswick County. The design alsoconforms to the requirements of the 2012 North Carolina Building Code.
This monopole has been intentionally designed to accommodate a theoretical fall radius. The upper 43’ ofthe pole has been designed to meet the wind loads of the design, however, the lower portion of the pole hasbeen designed with a minimum 10% extra capacity. Assuming the pole has been fabricated according tomy design and well maintained, in the event of a failure due to extreme wind and a comparableappurtenance antenna loads (winds in excess of the design wind load), it would yield/buckle at the 107’elevation. The yielded section would result in a maximum 43’ fall radius, but would most likely remainconnected and hang from the standing section.
The structure has been designed with all of the applicable factors as required by the code. A properlydesigned, constructed and maintained pole has never collapsed; monopoles are safe structures with a longhistory of reliable operation.
I hope this review of the monopole design has given you a greater degree of comfort regarding the designcapacity inherent in pole structures. If you have any additional questions please call me at 614-398-6250 oremail mike@mfpeng.com.
Sincerely,
Michael F. Plahovinsak, P.E.Professional Engineer
2.22.2016
Reviewed For Code Compliance
0'-0"
101'-0"
3/8" THK. x 49' LONG(EST. WT. = 6.819 KIPS
SPLICE LENGTH =6' (±10%)
26.0" ACROSS FLATS
150'-0"
65'-0"
3/4" THK. x 42' LONG(EST. WT. = 16.101 KIPS
SPLICE LENGTH =7'-6" (±10%)
31'-0"
7/8" THK. x 41'-6" LONG(EST. WT. = 22.714 KIPS
SPLICE LENGTH =9' (±10%)
0'-0"
1" THK. x 40' LONG(EST. WT. = 29.102 KIPS
75.5" ACROSS FLATS
BASEPLATE: 4'' THK X 89.5''ROUND W/(38) ANCHOR RODSON A 83.5'' B.C. MIN. 7'-0"EMBEDMENT INTO CONCRETE
145'-0"
130'-0"
120'-0"
110'-0"
Page of
Eng:
Structure:
Site:
Location:
Owner:
Revision No.:
Job Number:
Customer Ref:
Date:
Revision Date:
2 23515-0784TP-13942
2/22/2016
150-FT PINE TREE MONOPOLE
SUNSET HARBOR
BRUNSWICK CO., NC / 33°55'40.62", -78°12'10.92"
TOWERCOM
MFP
DESIGNBuilding Code:
Wind Speed Load Cases:
Load Case #1:
Design Standard:
MPH Design Wind Speed
Load Case #2:
2012 NORTH CAROLINA BUILDING CODE
ANSI/TIA-222-G-2
3-SEC. GUSTED WIND SPEED
140
30
60
0.25''
II C 1
EQUIPMENT LISTElev. Description
145 (12) PANEL ANTENNA + MOUNTING (288 FT2 / 6000 LBS)
145 T-ARM MOUNTS
130 (12) 8' X 1' PANEL + (9) RRU
130 12-FT T-ARM MOUNTS
120 (12) 8' X 1' PANEL + (9) RRU
120 12-FT T-ARM MOUNTS
110 (12) 8' X 1' PANEL + (9) RRU
110 12-FT T-ARM MOUNTS
PINE TREE BRANCHES SPACED EVENLY FROM 80'POLE DESIGNED FOR A 43' MAX FALL RADIUS
STRUCTURE PROPERTIESCross-Section:
Anchor Rods:
Shaft Steel:
Taper:
Baseplate Steel:
Sect. Length (ft) Thickness (in) Splice (ft) Top Dia. (in) Bot Dia. (in)
18-SIDED 0.35667 in/ft
ASTM A572 GR 65 ASTM A572 GR 50
2.5 in. F1554 GR. 105 X 8'-0"
1 49.00 0.3750 6.00 26.00 43.48
2 42.00 0.7500 7.50 40.59 55.57
3 41.50 0.8750 9.00 51.39 66.19
4 40.00 1.0000 0.00 61.23 75.50
Moment:
Shear:
Axial:
ft-kip
kip
kip
BASE REACTIONS FOR FOUNDATION DESIGN24348
217
123
Structure Class Exposure Cat. Topography Cat. Crest Height
Load Case #3
MPH Wind with Ice Accumulation
MPH Service Wind Speed
1
MICHAEL F. PLAHOVINSAK, P.E. #3280418301 S.R. 161, Plain City, OH 43064
614-398-6250 / mike@mfpeng.com
2.22.2016
Reviewed For Code Compliance
10'-0"Ø DRILLED SHAFT
6" ABOVE GRADE
(2) ADD'L REINFTIES WITHIN THE TOP5" OF CAISSON
(16) #5 HOR. TIESSPACED @ 6" O/C
2" CLEAR
3" GAP(GROUT NOT REQ'D.)
6'-0
"M
IN.
AB
EM
BEDM
ENT
3" CLEAR (TYP)
6" CLEAR
8'-0" LONG ANCHORROD 10"-12" PROJECTION W/HEAVY HEX LOCK NUT ANDLEVELING NUT
POLE SHAFT
CLOSE TIES WITHMIN. 24" LAP
50
'-6
"M
IN.
CAIS
SO
ND
EPTH
FINISHED GRADE
LOWER TIES @ 12" O/C
(62) #14 VERTICALREINF BARSEQUALLY SPACED
CL
Page of
Eng:
Structure:
Site:
Location:
Owner:
Revision No.:
Job Number:
Customer Ref:
Date:
Revision Date:
MFP
CAISSON FOUNDATION
2
FOUNDATION NOTES:
1. ALL FOUNDATION CONCRETE SHALL USE TYPE II CEMENT AND ATTAIN AMINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS. CONCRETESHALL HAVE A MAXIMUM WATER/CEMENT RATIO OF 0.46 AND SHALL BE AIRENTRAINED 6% (±1.5%). ALL CONCRETE CONSTRUCTION SHALL BE INACCORDANCE WITH ACI 318, "THE BUILDING CODE REQUIREMENTS FORREINFORCED CONCRETE", LATEST EDITION.
2. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 VERTICAL BARSSHALL BE GRADE 60, AND TIES OR STIRRUPS SHALL BE A MINIMUM OF GRADE40. THE PLACEMENT OF ALL REINFORCEMENT SHALL CONFORM TO ACI 315,"MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETESTRUCTURES", LATEST EDITION.
3. CAISSON FOUNDATION INSTALLATION SHALL BE IN ACCORDANCE WITH ACI336, "STANDARD SPECIFICATIONS FOR THE CONSTRUCTION OF DRILLED PIERS",LATEST EDITION.
4. THE CONTRACTOR SHALL DETERMINE THE MEANS AND METHODS TO SUPPORTTHE EXCAVATION DURING CONSTRUCTION. THE CONTRACTOR SHALL READ THEGEOTECHNICAL REPORT AND SHALL CONSULT THE GEOTECHNICAL ENGINEER ASNECESSARY PRIOR TO CONSTRUCTION.
5. FOUNDATION DESIGN IS BASED ON GEOTECHNICAL REPORT BY:ENGINEER: ENVIRONMENTAL CORP OF AMERICAREPORT NO.: R1463 (DATED 1/11/15)
6. ESTIMATED CONCRETE VOLUME = 148 CUBIC YARDS.
7. THE FOUNDATION HAS BEEN DESIGNED TO RESIST THE FOLLOWING FACTOREDLOADS:MOMENT: 24348 FT*KIPSSHEAR: 217 KIPSAXIAL: 123 KIPS
8. GEOTECHNICAL REPORT INDICATES GROUNDWATER MAY BE ENCOUNTERED AT
6'-0" BELOW GRADE.
Page of
Eng:
Structure:
Site:
Location:
Owner:
Revision No.:
Job Number:
Customer Ref:
Date:
Revision Date:
2 23515-0784TP-13942
2/22/2016
150-FT PINE TREE MONOPOLE
SUNSET HARBOR
BRUNSWICK CO., NC / 33°55'40.62", -78°12'10.92"
TOWERCOM
MFP
MICHAEL F. PLAHOVINSAK, P.E. #3280418301 S.R. 161, Plain City, OH 43064
614-398-6250 / mike@mfpeng.com
2.22.2016
Reviewed For Code Compliance
ttnnxxTToowweerrJob
150-ft Monopine - MFP #23515-784
Page
1 of 6
Michael F. Plahovinsak, P.E.18301 State Route 161
Project
Sunset Harbor
Date
12:21:02 01/05/16
Plain City, OH 43064Phone: 614-398-6250
FAX: mike@mfpeng.com
Client
TAPP (TP-13942)Designed by
Mike
Tower Input DataThis tower is designed using the TIA-222-G standard.The following design criteria apply:
Tower is located in Brunswick County, North Carolina.Basic wind speed of 140 mph.Structure Class II.Exposure Category C.Topographic Category 1.Crest Height 0.00 ft.Nominal ice thickness of 0.2500 in.Ice thickness is considered to increase with height.Ice density of 56 pcf.A wind speed of 30 mph is used in combination with ice.Temperature drop of 50 °F.Deflections calculated using a wind speed of 60 mph.A non-linear (P-delta) analysis was used.Pressures are calculated at each section.Stress ratio used in pole design is 1.Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered.
Tapered Pole Section Geometry
Section Elevation
ft
SectionLength
ft
SpliceLength
ft
Numberof
Sides
TopDiameter
in
BottomDiameter
in
WallThickness
in
BendRadius
in
Pole Grade
L1 150.00-101.00 49.00 6.00 18 26.0000 43.4800 0.3750 1.5000 A572-65(65 ksi)
L2 101.00-65.00 42.00 7.50 18 40.5896 55.5700 0.7500 3.0000 A572-65(65 ksi)
L3 65.00-31.00 41.50 9.00 18 51.3949 66.1900 0.8750 3.5000 A572-65(65 ksi)
L4 31.00-0.00 40.00 18 61.2314 75.5000 1.0000 4.0000 A572-65(65 ksi)
Tapered Pole Properties
Section Tip Dia.in
Areain2
Iin4
rin
Cin
I/Cin3
Jin4
It/Qin2
win
w/t
L1 26.4011 30.5002 2530.2723 9.0969 13.2080 191.5712 5063.8740 15.2530 3.9160 10.44344.1507 51.3057 12043.6628 15.3023 22.0878 545.2621 24103.1730 25.6577 6.9925 18.647
L2 43.3888 94.8381 19017.3624 14.1431 20.6195 922.2993 38059.7483 47.4281 5.8238 7.76556.4273 130.4990 49547.6122 19.4611 28.2296 1755.1677 99160.4204 65.2619 8.4603 11.28
L3 54.9028 140.3065 45241.8722 17.9346 26.1086 1732.8326 90543.2748 70.1666 7.5055 8.57867.2111 181.3961 97766.7592 23.1868 33.6245 2907.6031 195662.162
490.7153 10.1094 11.554
L4 65.4360 191.1746 87622.1480 21.3822 31.1056 2816.9282 175359.5914
95.6054 9.0167 9.017
76.6647 236.4630 165810.9436
26.4475 38.3540 4323.1721 331840.0656
118.2540 11.5280 11.528
Reviewed For Code Compliance
ttnnxxTToowweerrJob
150-ft Monopine - MFP #23515-784
Page
2 of 6
Michael F. Plahovinsak, P.E.18301 State Route 161
Project
Sunset Harbor
Date
12:21:02 01/05/16
Plain City, OH 43064Phone: 614-398-6250
FAX: mike@mfpeng.com
Client
TAPP (TP-13942)Designed by
Mike
Feed Line/Linear Appurtenances - Entered As Area
Description Faceor
Leg
AllowShield
ComponentType
Placement
ft
TotalNumber
CAAA
ft2/ft
Weight
plf1 5/8'' C No Inside Pole 145.00 - 0.00 18 No Ice
1/2'' Ice0.000.00
0.920.92
1 5/8'' C No Inside Pole 130.00 - 0.00 12 No Ice1/2'' Ice
0.000.00
0.920.92
1 5/8'' C No Inside Pole 120.00 - 0.00 12 No Ice1/2'' Ice
0.000.00
0.920.92
1 5/8'' C No Inside Pole 110.00 - 0.00 12 No Ice1/2'' Ice
0.000.00
0.920.92
Discrete Tower Loads
Description Faceor
Leg
OffsetType
Offsets:Horz
LateralVert
ftftft
AzimuthAdjustment
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
Panel Antennas + Mounting288 ft2 / 6000 lbs
C None 0.0000 145.00 No Ice1/2'' Ice
288.00300.00
288.00300.00
6.006.20
**(4) 96'' x 12'' x 3'' Panel w/
mount pipeA From Face 3.00
0.000.00
0.0000 130.00 No Ice1/2'' Ice
11.4712.08
5.907.65
0.090.16
(3) 24'' x 13'' x 7'' RemoteUnit
A From Face 2.000.000.00
0.0000 130.00 No Ice1/2'' Ice
3.033.28
1.631.84
0.060.08
(4) 96'' x 12'' x 3'' Panel w/mount pipe
B From Face 3.000.000.00
0.0000 130.00 No Ice1/2'' Ice
11.4712.08
5.907.65
0.090.16
(3) 24'' x 13'' x 7'' RemoteUnit
B From Face 2.000.000.00
0.0000 130.00 No Ice1/2'' Ice
3.033.28
1.631.84
0.060.08
(4) 96'' x 12'' x 3'' Panel w/mount pipe
C From Face 3.000.000.00
0.0000 130.00 No Ice1/2'' Ice
11.4712.08
5.907.65
0.090.16
(3) 24'' x 13'' x 7'' RemoteUnit
C From Face 2.000.000.00
0.0000 130.00 No Ice1/2'' Ice
3.033.28
1.631.84
0.060.08
12' T-Arm Mounts (MC-K12) C None 0.0000 130.00 No Ice1/2'' Ice
8.1510.59
8.1510.59
0.851.10
**(4) 96'' x 12'' x 3'' Panel w/
mount pipeA From Face 3.00
0.000.00
0.0000 120.00 No Ice1/2'' Ice
11.4712.08
5.907.65
0.090.16
(3) 24'' x 13'' x 7'' RemoteUnit
A From Face 2.000.000.00
0.0000 120.00 No Ice1/2'' Ice
3.033.28
1.631.84
0.060.08
(4) 96'' x 12'' x 3'' Panel w/mount pipe
B From Face 3.000.000.00
0.0000 120.00 No Ice1/2'' Ice
11.4712.08
5.907.65
0.090.16
(3) 24'' x 13'' x 7'' RemoteUnit
B From Face 2.000.000.00
0.0000 120.00 No Ice1/2'' Ice
3.033.28
1.631.84
0.060.08
(4) 96'' x 12'' x 3'' Panel w/mount pipe
C From Face 3.000.00
0.0000 120.00 No Ice1/2'' Ice
11.4712.08
5.907.65
0.090.16
Reviewed For Code Compliance
ttnnxxTToowweerrJob
150-ft Monopine - MFP #23515-784
Page
3 of 6
Michael F. Plahovinsak, P.E.18301 State Route 161
Project
Sunset Harbor
Date
12:21:02 01/05/16
Plain City, OH 43064Phone: 614-398-6250
FAX: mike@mfpeng.com
Client
TAPP (TP-13942)Designed by
Mike
Description Faceor
Leg
OffsetType
Offsets:Horz
LateralVert
ftftft
AzimuthAdjustment
°
Placement
ft
CAAA
Front
ft2
CAAA
Side
ft2
Weight
K
0.00(3) 24'' x 13'' x 7'' Remote
UnitC From Face 2.00
0.000.00
0.0000 120.00 No Ice1/2'' Ice
3.033.28
1.631.84
0.060.08
12' T-Arm Mounts (MC-K12) C None 0.0000 120.00 No Ice1/2'' Ice
8.1510.59
8.1510.59
0.851.10
**(4) 96'' x 12'' x 3'' Panel w/
mount pipeA From Face 3.00
0.000.00
0.0000 110.00 No Ice1/2'' Ice
11.4712.08
5.907.65
0.090.16
(3) 24'' x 13'' x 7'' RemoteUnit
A From Face 2.000.000.00
0.0000 110.00 No Ice1/2'' Ice
3.033.28
1.631.84
0.060.08
(4) 96'' x 12'' x 3'' Panel w/mount pipe
B From Face 3.000.000.00
0.0000 110.00 No Ice1/2'' Ice
11.4712.08
5.907.65
0.090.16
(3) 24'' x 13'' x 7'' RemoteUnit
B From Face 2.000.000.00
0.0000 110.00 No Ice1/2'' Ice
3.033.28
1.631.84
0.060.08
(4) 96'' x 12'' x 3'' Panel w/mount pipe
C From Face 3.000.000.00
0.0000 110.00 No Ice1/2'' Ice
11.4712.08
5.907.65
0.090.16
(3) 24'' x 13'' x 7'' RemoteUnit
C From Face 2.000.000.00
0.0000 110.00 No Ice1/2'' Ice
3.033.28
1.631.84
0.060.08
12' T-Arm Mounts (MC-K12) C None 0.0000 110.00 No Ice1/2'' Ice
8.1510.59
8.1510.59
0.851.10
**Pine Tree Branches C None 0.0000 147.60 No Ice
1/2'' Ice77.0088.00
0.000.00
0.660.78
Pine Tree Branches C None 0.0000 134.40 No Ice1/2'' Ice
135.00155.00
0.000.00
1.161.36
Pine Tree Branches C None 0.0000 118.90 No Ice1/2'' Ice
163.00188.00
0.000.00
1.401.65
Pine Tree Branches C None 0.0000 103.30 No Ice1/2'' Ice
191.00221.00
0.000.00
1.651.93
Pine Tree Branches C None 0.0000 87.80 No Ice1/2'' Ice
219.00253.00
0.000.00
1.892.22
Load Combinations
Comb.No.
Description
1 Dead Only2 1.2 Dead+1.6 Wind 0 deg - No Ice3 0.9 Dead+1.6 Wind 0 deg - No Ice4 1.2 Dead+1.6 Wind 90 deg - No Ice5 0.9 Dead+1.6 Wind 90 deg - No Ice6 1.2 Dead+1.6 Wind 180 deg - No Ice7 0.9 Dead+1.6 Wind 180 deg - No Ice8 1.2 Dead+1.0 Ice+1.0 Temp9 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp10 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp11 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp12 Dead+Wind 0 deg - Service
Reviewed For Code Compliance
ttnnxxTToowweerrJob
150-ft Monopine - MFP #23515-784
Page
4 of 6
Michael F. Plahovinsak, P.E.18301 State Route 161
Project
Sunset Harbor
Date
12:21:02 01/05/16
Plain City, OH 43064Phone: 614-398-6250
FAX: mike@mfpeng.com
Client
TAPP (TP-13942)Designed by
Mike
Comb.No.
Description
13 Dead+Wind 90 deg - Service14 Dead+Wind 180 deg - Service
Maximum Member Forces
SectionNo.
Elevationft
ComponentType
Condition Gov.Load
Comb.
Axial
K
Major AxisMoment
kip-ft
Minor AxisMoment
kip-ftL1 150 - 101 Pole Max Tension 2 0.00 0.00 -0.00
Max. Compression 8 -34.65 0.00 0.00Max. Mx 4 -18.46 -2945.22 0.00Max. My 2 -18.46 0.00 2945.22Max. Vy 4 121.76 -2945.22 0.00Max. Vx 2 -121.76 0.00 2945.22
L2 101 - 65 Pole Max Tension 1 0.00 0.00 0.00Max. Compression 8 -59.43 0.00 0.00
Max. Mx 4 -42.18 -8288.91 0.00Max. My 2 -42.18 0.00 8288.91Max. Vy 4 174.50 -8288.91 0.00Max. Vx 2 -174.50 0.00 8288.91
L3 65 - 31 Pole Max Tension 1 0.00 0.00 0.00Max. Compression 8 -87.53 0.00 0.00
Max. Mx 4 -72.94 -14114.26 0.00Max. My 2 -72.94 0.00 14114.26Max. Vy 4 183.68 -14114.26 0.00Max. Vx 2 -183.68 0.00 14114.26
L4 31 - 0 Pole Max Tension 1 0.00 0.00 0.00Max. Compression 8 -133.29 0.00 0.00
Max. Mx 4 -121.40 -21669.17 0.00Max. My 2 -121.40 0.00 21669.17Max. Vy 4 193.45 -21669.17 0.00Max. Vx 2 -193.45 0.00 21669.17
Maximum Tower Deflections - Service Wind
SectionNo.
Elevation
ft
Horz.Deflection
in
Gov.Load
Comb.
Tilt
°
Twist
°
L1 150 - 101 10.449 12 0.6572 0.0000L2 107 - 65 5.074 12 0.4712 0.0000L3 72.5 - 31 2.239 12 0.2988 0.0000L4 40 - 0 0.669 12 0.1498 0.0000
Critical Deflections and Radius of Curvature - Service Wind
Elevation
ft
Appurtenance Gov.Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius ofCurvature
ft147.60 Pine Tree Branches 12 10.123 0.6474 0.0000 70509145.00 Panel Antennas + Mounting 288 ft2
/ 6000 lbs12 9.772 0.6367 0.0000 70509
134.40 Pine Tree Branches 12 8.357 0.5926 0.0000 22599130.00 (4) 96'' x 12'' x 3'' Panel w/ mount
pipe12 7.784 0.5741 0.0000 17627
120.00 (4) 96'' x 12'' x 3'' Panel w/ mount 12 6.537 0.5307 0.0000 11751
Reviewed For Code Compliance
ttnnxxTToowweerrJob
150-ft Monopine - MFP #23515-784
Page
5 of 6
Michael F. Plahovinsak, P.E.18301 State Route 161
Project
Sunset Harbor
Date
12:21:02 01/05/16
Plain City, OH 43064Phone: 614-398-6250
FAX: mike@mfpeng.com
Client
TAPP (TP-13942)Designed by
Mike
Elevation
ft
Appurtenance Gov.Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius ofCurvature
ftpipe
118.90 Pine Tree Branches 12 6.406 0.5259 0.0000 11335110.00 (4) 96'' x 12'' x 3'' Panel w/ mount
pipe12 5.392 0.4853 0.0000 8831
103.30 Pine Tree Branches 12 4.699 0.4533 0.0000 857587.80 Pine Tree Branches 12 3.326 0.3759 0.0000 10584
Maximum Tower Deflections - Design Wind
SectionNo.
Elevation
ft
Horz.Deflection
in
Gov.Load
Comb.
Tilt
°
Twist
°
L1 150 - 101 101.633 4 6.3969 0.0000L2 107 - 65 49.400 4 4.5883 0.0000L3 72.5 - 31 21.808 4 2.9105 0.0000L4 40 - 0 6.522 4 1.4600 0.0000
Critical Deflections and Radius of Curvature - Design Wind
Elevation
ft
Appurtenance Gov.Load
Comb.
Deflection
in
Tilt
°
Twist
°
Radius ofCurvature
ft
147.60 Pine Tree Branches 4 98.474 6.3010 0.0000 7410145.00 Panel Antennas + Mounting 288 ft2
/ 6000 lbs4 95.058 6.1971 0.0000 7410
134.40 Pine Tree Branches 4 81.307 5.7694 0.0000 2373130.00 (4) 96'' x 12'' x 3'' Panel w/ mount
pipe4 75.746 5.5889 0.0000 1850
120.00 (4) 96'' x 12'' x 3'' Panel w/ mountpipe
4 63.627 5.1677 0.0000 1231
118.90 Pine Tree Branches 4 62.348 5.1202 0.0000 1187110.00 (4) 96'' x 12'' x 3'' Panel w/ mount
pipe4 52.497 4.7259 0.0000 922
103.30 Pine Tree Branches 4 45.753 4.4151 0.0000 89487.80 Pine Tree Branches 4 32.397 3.6614 0.0000 1097
Pole Design Data
SectionNo.
Elevation
ft
Size L
ft
Lu
ft
Kl/r A
in2
Pu
K
Pn
K
RatioPu
Pn
L1 150 - 101 (1) TP43.48x26x0.375 49.00 0.00 0.0 48.7581 -18.46 3539.12 0.005L2 101 - 65 (2) TP55.57x40.5896x0.75 42.00 0.00 0.0 124.131
0-42.18 9222.31 0.005
L3 65 - 31 (3) TP66.19x51.3949x0.875 41.50 0.00 0.0 172.4850
-72.94 12814.80 0.006
L4 31 - 0 (4) TP75.5x61.2314x1 40.00 0.00 0.0 212.4480
-98.93 15783.80 0.006
Reviewed For Code Compliance
ttnnxxTToowweerrJob
150-ft Monopine - MFP #23515-784
Page
6 of 6
Michael F. Plahovinsak, P.E.18301 State Route 161
Project
Sunset Harbor
Date
12:21:02 01/05/16
Plain City, OH 43064Phone: 614-398-6250
FAX: mike@mfpeng.com
Client
TAPP (TP-13942)Designed by
Mike
Pole Bending Design Data
SectionNo.
Elevation
ft
Size Mux
kip-ft
Mnx
kip-ft
RatioMux
Mnx
Muy
kip-ft
Mny
kip-ft
RatioMuy
Mny
L1 150 - 101 (1) TP43.48x26x0.375 2945.22 2977.42 0.989 0.00 2977.42 0.000L2 101 - 65 (2) TP55.57x40.5896x0.75 8288.91 9825.25 0.844 0.00 9825.25 0.000L3 65 - 31 (3) TP66.19x51.3949x0.875 14114.25 16265.42 0.868 0.00 16265.42 0.000L4 31 - 0 (4) TP75.5x61.2314x1 17616.17 21573.00 0.817 0.00 21573.00 0.000
Pole Shear Design Data
SectionNo.
Elevation
ft
Size ActualVu
K
Vn
K
RatioVu
Vn
ActualTu
kip-ft
Tn
kip-ft
RatioTu
Tn
L1 150 - 101 (1) TP43.48x26x0.375 121.76 1744.27 0.070 0.00 5962.11 0.000L2 101 - 65 (2) TP55.57x40.5896x0.75 174.50 4611.16 0.038 0.00 19674.50 0.000L3 65 - 31 (3) TP66.19x51.3949x0.875 183.68 6407.39 0.029 0.00 32570.58 0.000L4 31 - 0 (4) TP75.5x61.2314x1 189.16 7960.54 0.024 0.00 43198.83 0.000
Pole Interaction Design Data
SectionNo.
Elevation
ft
RatioPu
Pn
RatioMux
Mnx
RatioMuy
Mny
RatioVu
Vn
RatioTu
Tn
Comb.StressRatio
Allow.StressRatio
Criteria
L1 150 - 101 (1) 0.005 0.989 0.000 0.070 0.000 0.999 1.0004.8.2
L2 101 - 65 (2) 0.005 0.844 0.000 0.038 0.000 0.850 1.0004.8.2
L3 65 - 31 (3) 0.006 0.868 0.000 0.029 0.000 0.874 1.0004.8.2
L4 31 - 0 (4) 0.006 0.817 0.000 0.024 0.000 0.823 1.0004.8.2
Section Capacity Table
SectionNo.
Elevationft
ComponentType
Size CriticalElement
PK
øPallow
K%
CapacityPassFail
L1 150 - 101 Pole TP43.48x26x0.375 1 -18.46 3539.12 99.9 PassL2 101 - 65 Pole TP55.57x40.5896x0.75 2 -42.18 9222.31 85.0 PassL3 65 - 31 Pole TP66.19x51.3949x0.875 3 -72.94 12814.80 87.4 PassL4 31 - 0 Pole TP75.5x61.2314x1 4 -98.93 15783.80 82.3 Pass
SummaryPole (L1) 99.9 Pass
RATING = 99.9 Pass
Reviewed For Code Compliance
ANSI/TIA-222-G-2
Factored Base Reactions: Pole Shape: Anchor Rods: Base Plate:
Moment: 21669 ft-kips 18-Sided (38) 2.5 in. F1554 GR. 105 4 in. x 89.5 in. Round
Shear: 193 kips Pole Dia. (D f ): Anchor Rods Evenly Spaced fy = 50 ksi
Axial: 122 kips 75.50 in On a 83.5 in Bolt Circle
Anchor Rod Calculation According to TIA-222-G section 4.9.9
f = 0.80 TIA 4.9.9 The following Interation Equation Shall Be Satisfied:
Ibolts = 33118.19 in2
Momet of Inertia Vu
Pu = 328 kips Tension Force h
Vu = 5 kips Shear Force
Rnt = 500.00 kips Nominal Tensile Strength
h = 0.50 for detail type (d) 0.845 1
Base Plate Calculation According to TIA-222-G
f = 0.90 TIA 4.7
MPL = 910.3 in-kip Plate Moment
L = 6.2 in Section Length
Z = 25.0 Plastic Section Modulus 910.28 in-kip 1124 in-kip
MP = 1248.4 in-kip Plastic Moment
f Mn= 1123.5 in-kip Factored Resistance
Anchor Rods Are Adequate 84.5% R
Base Plate is Adequate 81.0% R
150-ft pine tree monopole - MFP #23515-0784 BP-G
Sunset Harbor 2/22/2016
TAPP TP-13942 Mike
Anchor Rod and Base Plate Calculation
Pu +1.0
fRnt
Calculated Moment vs Factored Resistance
Michael F. Plahovinsak, P.E.18301 State Route 161 W
Plain City, OH 43064Phone: 614-398-6250
email: mike@mfpeng.com
Job
Project
Client
Page
Date
Designed by
Reviewed For Code Compliance
According to ANSI/TIA-222-G-2
*** PIER PROPERTIES CONCRETE STRENGTH (ksi) = 4.00 STEEL STRENGTH (ksi) = 60.00
DIAMETER (ft) = 10.000 DISTANCE FROM TOP OF PIER TO GROUND LEVEL (ft) = 0.50
*** SOIL PROPERTIES LAYER TYPE THICKNESS DEPTH AT TOP OF LAYER DENSITY CU KP PHI(ft) (ft) (pcf) (psf) (degrees)
1 S 6.00 0.00 0.0 1.000 -0.002 S 17.50 6.00 50.0 2.880 28.983 S 15.00 23.50 50.0 3.390 32.984 S 20.00 38.50 65.0 4.020 36.98
*** DESIGN (FACTORED) LOADS AT TOP OF PIER MOMENT (ft-k) = 24348.0 VERTICAL (k) = 123.0 SHEAR (k) = 217.0ADDITIONAL SAFETY FACTOR AGAINST SOIL FAILURE = 1.33
*** CALCULATED PIER LENGTH (ft) = 51.000
*** CHECK OF SOILS PROPERTIES AND ULTIMATE RESISTING FORCES ALONG PIER
TYPE TOP OF LAYER BELOW TOP OF PIER THICKNESS DENSITY CU KP FORCE ARM(ft) (ft) (pcf) (psf) (k) (ft)
S 0.50 6.00 0.0 1.000 0.00 4.50S 6.50 17.50 50.0 2.880 661.50 18.17S 24.00 15.00 50.0 3.390 1906.88 32.25S 39.00 1.58 65.0 4.020 318.57 39.80S 40.58 10.42 65.0 4.020 -2597.54 46.07
*** SHEAR AND MOMENTS ALONG PIERWITH THE ADDITIONAL SAFETY FACTOR WITHOUT ADDITIONAL SAFETY FACTOR
DISTANCE BELOW TOP OF PIER (ft) SHEAR (k) MOMENT (ft-k) SHEAR (k) MOMENT (ft-k)0.00 289.4 33484.4 217.1 25113.35.10 289.4 34960.3 217.1 26220.310.20 259.8 36399.8 194.9 27299.915.30 122.1 37421.5 91.6 28066.220.40 -127.9 37454.5 -96.0 28090.925.50 -511.3 35910.1 -383.5 26932.730.60 -1070.2 31933.6 -802.6 23950.235.70 -1761.3 24769.5 -1321.0 18577.240.80 -2550.7 13701.6 -1913.0 10276.245.90 -1377.3 3598.7 -1033.0 2699.051.00 0.0 -0.0 0.0 -0.0
*** TOTAL REINFORCEMENT PCT = 1.22 REINFORCEMENT AREA (in^2) = 137.98*** USABLE AXIAL CAP. (k) = 123.0 USABLE MOMENT CAP. (ft-k) = 28545.0
Minimum Steel Per ACI-318 in2
For Design:
36.43
10-ft Diameter caisson x 51-ft long (50.5-ft Embeded with 0.5-ft above grade)
Concrete strength =4000 PSI @ 28 days. Estimated Concrete Volume = 148 CY3.
Caisson Calculation
5. Foundation has been designed with factored loads per TIA-222-G.
6. Design water table = 6 ft below grade
1. Foundation overturning resistance calculated with PLS Caisson, for Brom's method for rigid piles. Soil layers modeled after recommendations from the geotechnical report.
2. Cohesion strength for the upper 30 ft has been reduced by 50%
3. In lieu of a soil resistance factor fs = 0.75 (TIA-9.4.1) an additional safey fator against soil failure of 1.33 has been applied.
4. Foundation is designed with a minimum safety factor resisting overturning of 2.0
Approx. Foundation Usage 0.0%
(62) #14 Vertical Rebar. Steel Cross-Section = 139.5 in2
TAPP TP-13942 Mike
150-ft pine tree monopole - MFP #23515-0784 FND
Sunset Harbor 2/22/2016
Michael F. Plahovinsak, P.E.18301 State Route 161 W
Plain City, OH 43064Phone: 614-398-6250
email: mike@mfpeng.com
Job
Project
Client
Page
Date
Designed by
Reviewed For Code Compliance
Copyright 2015 STEALTH} Concealment Solutions, Inc. All Rights Reserved
SAFETY. INTEGRITY. TRUST. EXPERIENCE.
FABRICATION DRAWINGS
TOWERCOM
SUNSET HARBOR
BRUNSWICK CO.
NORTH CAROLINA
STEALTH JOB #: TC15-01729W-05R0
DRAWING INDEX
REVISION
STEALTHFIRST IN CONCEALMENT
}
01-7-16
T1
TM
3034-A ASHLEY PHOSPHATE RD. NORTH CHARLESTON, SC 29418 P: (800)-755-0689 / F: (843)-207-0207 WWW.STEALTHCONCEALMENT.COM
PROJECT MANAGER: BRAD BALKHAM ; 843-573-2013
WE ARE STEALTH .
THE } MAKES THE DIFFERENCE.
}
T1 TITLE SHEETN1-N2 NOTES & SPECIFICATIONSA1 ASSEMBLY - PARTS LISTA2 BRANCH LAYOUTD1 STEEL DETAILS
Reviewed For Code Compliance
Copyright 2015 STEALTH} Concealment Solutions, Inc. All Rights Reserved We are STEALTH}. The } Makes the Difference!
PROPRIETARY INFORMATION
THE INFORMATION CONTAINED WITHIN THIS DRAWING SET IS PROPRIETARY & CONFIDENTIAL
BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO
STEALTH} CONCEALMENT SOLUTIONS, INC
IS STRICTLY PROHIBITED.
3034-A ASHLEY PHOSPHATE RD.NORTH CHARLESTON, SC 29418
P: (800)-755-0689 F: (843)-207-0207WWW.STEALTHCONCEALMENT.COM
DRAWING NOT TO SCALE. UNLESS SPECIFIED
OTHERWISE DIMENSIONS SHOWN ARE IN INCHES
TOLERANCESDECIMALSX ± 1/16"
.XXX ± 0.01"
ANGULAR
X ± 0.5°
REVISION
JOB #:DRAWN:DESIGNED:REVISED:
TOWERCOM
SUNSET HARBOR
BRUNSWICK CO.
NORTH CAROLINA
DLDL
N2 1-7-16 0
STEALTHFIRST IN CONCEALMENT
}
NOTES & SPECIFICATIONS
TC15-01729W-05R0
TM
REVISION TABLE
REVISION DESIGNER DATE SCOPE OF REVISION
0 DL 1-7-16 BRANCH LAYOUT
Reviewed For Code Compliance
DETAIL B
ISOMETRIC
PART # 200 - MONOPOLE - PARTS LIST - PROVIDED BY POLE VENDOR
SHEETMATERIALDESCRIPTIONQTYITEM
D1ASTM A500 GR. B5° BRANCH RECEIVER 66201
D1ASTM A500 GR. B15° BRANCH RECEIVER 45202
D1ASTM A500 GR. B30° BRANCH RECEIVER 15203
D1ASTM A500 GR. B45° BRANCH RECEIVER 9204
D1ASTM A500 GR. B60° BRANCH RECEIVER 3205
PROPRIETARY INFORMATION
THE INFORMATION CONTAINED WITHIN THIS DRAWING SET IS PROPRIETARY & CONFIDENTIAL
BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO
STEALTH} CONCEALMENT SOLUTIONS, INC
IS STRICTLY PROHIBITED.
3034-A ASHLEY PHOSPHATE RD.NORTH CHARLESTON, SC 29418
P: (800)-755-0689 F: (843)-207-0207WWW.STEALTHCONCEALMENT.COM
DRAWING NOT TO SCALE. UNLESS SPECIFIED
OTHERWISE DIMENSIONS SHOWN ARE IN INCHES
TOLERANCESDECIMALSX ± 1/16"
.XXX ± 0.01"
ANGULAR
X ± 0.5°
REVISION
JOB #:DRAWN:DESIGNED:REVISED:
TOWERCOM
SUNSET HARBOR
BRUNSWICK CO.
NORTH CAROLINA
DLDL
A1 1-7-16 0
STEALTHFIRST IN CONCEALMENT
}
ASSEMBLY - PARTS LIST
TC15-01729W-05R0
TM
Copyright 2015 STEALTH} Concealment Solutions, Inc. All Rights Reserved We are STEALTH}. The } Makes the Difference!
PART #100 - MONOPINE - PARTS LIST
SHEETMATERIALDESCRIPTIONPACKING QTYQTYITEM
--- 4' BRANCH66101
--- 6' BRANCH4545102
--- 8' BRANCH4545103
--- 10' BRANCH4242104
---STAINLESS STEEL1/4" x 3" FULL THREAD BOLT SS183138105
---STAINLESS STEEL1/4" FLAT WASHER SS276276106
---STAINLESS STEEL1/4" LOCK WASHER SS138138107
---STAINLESS STEEL1/4" HEX NUT SS138138108
205
204
203
201
FABRICATION NOTE - DETAILS ARE GENERIC TO ILLUSTRATE
VERTICAL ORIENTATION OF BRANCHES ETC.SPECIFIC ELEVATIONS, POLAR ORIENTATIONS & NUMBER OF ROWS FOR
ALL RECEIVERS ARE TO BE INSTALLED PER THE TREE BRANCH(BRANCH LAYOUT) SHEETS.
RECEIVERS TO BE RE-LOCATED TO AVOID ANY REQUIREDFEATURES SUCH AS HAND-HOLES AND STEP BOLTS
201
203
204
205
105 106 107 108PINE BRANCHES SHOWN FORESHORTENED
202
202
202202
75°
30°
45°
60°
75°
85°
Reviewed For Code Compliance
Copyright 2015 STEALTH} Concealment Solutions, Inc. All Rights Reserved We are STEALTH}. The } Makes the Difference!
PROPRIETARY INFORMATION
THE INFORMATION CONTAINED WITHIN THIS DRAWING SET IS PROPRIETARY & CONFIDENTIAL
BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO
STEALTH} CONCEALMENT SOLUTIONS, INC
IS STRICTLY PROHIBITED.
3034-A ASHLEY PHOSPHATE RD.NORTH CHARLESTON, SC 29418
P: (800)-755-0689 F: (843)-207-0207WWW.STEALTHCONCEALMENT.COM
DRAWING NOT TO SCALE. UNLESS SPECIFIED
OTHERWISE DIMENSIONS SHOWN ARE IN INCHES
TOLERANCESDECIMALSX ± 1/16"
.XXX ± 0.01"
ANGULAR
X ± 0.5°
REVISION
JOB #:DRAWN:DESIGNED:REVISED:
TOWERCOM
SUNSET HARBOR
BRUNSWICK CO.
NORTH CAROLINA
DLDL
A2 1-7-16 0
STEALTHFIRST IN CONCEALMENT
}
BRANCH LAYOUT
TC15-01729W-05R0
TM
Reviewed For Code Compliance
GALVANIZATION NOTES:
-GALVANIZATION BUILD UP MUST BE MINIMIZED TO INSURE BRANCHES WILL FIT INTO RECEIVERS AFTER BEING GALVANIZED.
-A TEST BRANCH MUST BE INSERTED INTO EVERY RECEIVER AFTER
GALVANIZATION TO INSURE BRANCHES WILL FIT ON SITE.
PROPRIETARY INFORMATION
THE INFORMATION CONTAINED WITHIN THIS DRAWING SET IS PROPRIETARY & CONFIDENTIAL
BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO
STEALTH} CONCEALMENT SOLUTIONS, INC
IS STRICTLY PROHIBITED.
3034-A ASHLEY PHOSPHATE RD.NORTH CHARLESTON, SC 29418
P: (800)-755-0689 F: (843)-207-0207WWW.STEALTHCONCEALMENT.COM
DRAWING NOT TO SCALE. UNLESS SPECIFIED
OTHERWISE DIMENSIONS SHOWN ARE IN INCHES
TOLERANCES
DECIMALS
X ± 1/16"
.XXX ± 0.01"
ANGULAR
X ± 0.5°
REVISION
JOB #:DRAWN:DESIGNED:REVISED:
TOWERCOM
SUNSET HARBOR
BRUNSWICK CO.
NORTH CAROLINA
DLDL
D1 1-7-16 0
STEALTHFIRST IN CONCEALMENT
}
STEEL DETAILS
TC15-01729W-05R0
PN SYMBOL DENOTES LOCATION OF PART NUMBER
TM
Copyright 2015 STEALTH} Concealment Solutions, Inc. All Rights Reserved We are STEALTH}. The } Makes the Difference!
1 1/2"
1 1/2"
9 1/8"
n2 3/8" [2.375]
1/8" [.154]
n3/8 THRU 2X
20215° BRANCH RECEIVER
NEW RECIEVER 15.ipt
1 1/2"
9 7/8"
n3/8 THRU
n2 3/8" [2.375]
1/8" [.154]
20330° BRANCH RECEIVER
NEW RECIEVER 30.ipt
1 1/2"
n3/8 THRU
n2 3/8" [2.375]
1/8" [.154]
20445° BRANCH RECEIVER
NEW RECIEVER 45.ipt
1'- 5/8"
1 1/2"
n2 3/8" [2.375]
1/8" [.154]
n3/8 THRU
20560° BRANCH RECEIVER
NEW RECIEVER 60.ipt
n2 3/8" [2.375]
1/8" [.154]
8 11/16"
8"
!!!!
5°8 1/2"
n3/8 THRU
15°
n3/8" WEEP HOLE
THRU THIS SIDE ONLY
n3/8" WEEP HOLE
THRU THIS SIDE ONLY
8 1/2"
30°
8 1/2"
n3/8" WEEP HOLE
THRU THIS SIDE ONLY
45°
8 1/2"
10 7/8"
n3/8" WEEP HOLE
THRU THIS SIDE ONLY
60°
8 1/2"
n3/8" WEEP HOLE
THRU THIS SIDE ONLY
8 1/2"
9"
10"
11 3/4"
WEEP HOLE AT "BOTTOM" OF RECEIVER
WEEP HOLE AT "BOTTOM" OF RECEIVER
WEEP HOLE AT "BOTTOM" OF RECEIVER
WEEP HOLE AT "BOTTOM" OF RECEIVER
WEEP HOLE AT "BOTTOM"
OF RECEIVER
7 15/16"n3/8 THRU
8 1/8"n3/8 THRU
8 1/2"
n3/8 THRU
8 3/4"
n3/8 THRU
9 3/8"
n3/8 THRU
2015° BRANCH RECEIVER
NEW RECIEVER 0.ipt
Reviewed For Code Compliance
Reviewed For Code Compliance
Reviewed For Code Compliance
Recommended