Series 3100 and Series 3200

Preview:

Citation preview

Series 3100 and 3200Industrial Pressure Transmitter

The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc.

©Copyright 2011 Dwyer Instruments, Inc

Can be configured with Zero/Span buttons, HART handheld communicator or HART communicator softwareFM and CE approved

FM: Class I, Div I, Group A, B, C and D

High or Low fail safe Output: 4-20mA / HARTAdditional terminals for HART communicator and multimeter. LCD and enclosure can be rotated100:1 TurndownAccuracy: 0.075% F.S.

Features

Enclosure Adjustments

Enclosure can be rotated 360⁰

LCD can be rotated 270⁰

Mechanical Features

3100 comes standard with bleed fittings

Front and back enclosure covers are lockable.

Smart Transmitter

Nonlinearities and temperature dependencies of the pressure sensor are eliminated. Smart

TransmitterConventional Transmitter

HARTThe 3100/3200 transmitters are equipped with analog (4-20mA) and digital (HART) communication.

Push Button ConfigurationThe 3100/3200 can be configured using the Zero/Span buttons The Zero/Span buttons allow the transmitter to be configured without opening the housing covers

Failsafe

The failsafe can be programmed to fail High (21.75mA) or Low (3.75mA) if the self-diagnostic test detects a failure.

Turndown ExplanationExample:

Nominal lower value (LRL) = 0 barNominal upper value (URL) = 100 barLower-range value (LRV) = 0 barUpper-range value (URV) = 1 bar

Turndown:Nominal upper value(URL)/Upper-range value (URV)

100/1 barTD = 100:1

Installation

Steam Service

Liquid Service

Air Service

Calibration Frequency

Calculations

Options

Diaphragm Seals

Options316 SS Housing

AccessoriesBBV Valve Manifolds

2 Valve Manifolds 3 Valve Manifolds5 Valve Manifolds

COM-PC HART Communicator Software

HART Software with all registered DD (Device Description) filesIncludes USB HART Modem

Water & Waste Water FacilitiesChemical & Petrochemical PlantsOil & Gas RefineriesPulp & Paper Processing PlantsFood & Beverage PlantsRenewable Energy & Alternative Fuels Soil RemediationIron & Steel FoundriesTest & Measurement Labs

Target Industries

Level ApplicationThe 3100 can be used to monitor the level in a closed or open tank. The transmitter range can be adjusted to compensate for specific gravity.

Gas Train ApplicationThe 3100 is used to monitor the air or air/gas mixture flow into a combustion chamber.

Filter ApplicationsThe 3100 can be used to measure the pressure drop across air filters, liquid filters and reverse osmosis systems in hazardous locations.

Refining Application

The 3100 and 3200 are used to monitor processes converting raw resources to refined natural gas, diesel or gasoline.

Oil Well Application

The 3200 is used to monitor the well pressure to prevent blowouts.

Water Pressure Application

The 3200 is used to monitor the water level in a tower and pump pressure.

Food Processing Application

The 3200 is used to monitor pressure in cooking and processing lines to prevent blockages.

Questions

To order a free catalog or for more information contact;Dwyer Instruments, Inc., P.O. Box 373,

Michigan City, IN., 46361Telephone: (800) 872-9141 or (219) 879-8000

Fax: (219) 872-9057Internet address: www.dwyer-inst.com

E-mail: info@dwyer-inst.com

Recommended