View
16
Download
0
Category
Preview:
Citation preview
Den Helder, The Netherlands
+31 (0)223 747 001
info@endures.nl
Index of presentation
Endures B.V. Ambition / vision Our team Outstanding projects Market Segments Some of Endures Clients Top clients of Endures in expertise areas Expertise areas
Corrosion, Failure analysis and electrochemistry
Performance of protective and antifouling coatings
Microbiological effects on materials Knowledge Facilities
Corrosion, Failure analysis and Antifouling research since 1964 Expertise
Corrosion Electrochemistry Metallurgy Antifouling Microbiology Coatings Material durability in seawater (composites, adhesive joints)
Fresh natural seawater Outdoor exposure In-house laboratory of Royal Netherlands Navy
Endures BV, Den Helder, The Netherlands
Ambition: Endures wants to become a European Centre of Excellence for consultancy and applied research in corrosion,
failure analysis and fouling control by turning present single customer projects and services into recurrent multi-client
business programs using professional marketing and sales tools. This leads to higher profits that can be invested in advanced
new unique infrastructure and knowledge to ensure unique high level competences.
Vision: Use of comprehensive knowledge from material, environmental and biological perspective yields optimal and integral
solutions for our customers.
Endures BV, Den Helder, The Netherlands
ManufacturingDesign
MaintenanceFailure
€ndurance of your assets
Endures BV, Our team
Mark Bakker Biofouling and MIC
Job Klijnstra Antifouling and Biofouling
Babs MouthaanOffice assistant
Paul JongeriusTechnical assistant
Xiaolong Zhang Corrosion
Merlina KranenburgMicrobiology and Biofilms
Sibo ButerCorrosion and Coatings
Hans Christ Corrosion and Failure Analysis
Nanni Noel MIC
Gijsbert Strijk Corrosion and Failure Analysis
Raphael FredonElectrochemistry & Materials Science
Projects examples
Clients Project
Armacell Corrosion under insulation
Damen Coating performance (EIS) at 15 ballast water tanks of large navy ship
Allseas MV Pioneering Spirit: coating damage AntiFouling
Philips Lightning UV irradiation for antifouling purpose
Hempel A/S Friction drag performance of antifouling coatings
Shell Corrosion and MIC (Microbiologically Influenced Corrosion) at welds of Inconel 625
Evides MIC monitoring in water distribution grid of BASF (Antwerp)
MCN-efro High pressure (700 bar) and arctic corrosion test set ups
Endures BV, Market Segments
Maritime & Offshore
Paint Suppliers
Navy Oil & Gas Water companies
Ship builders
Some of Endures Clients
Corrosion, Failure analysis and Electrochemistry
Sample preparation Mechanical testing Optical microscopy Electron microscopy
Carbon steel Stainless steel Aluminum alloys Copper alloys
Polarisation resistanceOpen Corrosion PotentialElectrochemical Impedance Spectroscopy (EIS)
Electrochemical Noise Resistance
Cathodic disbondment
Durability and life time prediction
SEM-EDX 3D & Stereo microscope
Performance of protective and antifouling coatingsProtective CoatingsTechnology: early detection of corrosion and coating degradationModel based life time prediction: coating selection and condition based maintenance
H2O, O2
Na+, Cl-
Fe2+
corrosie-producten
anode
e-
kathodekathode
e-
Na+, OH-Na+, OH-
Antifouling Coatings•Laboratory bioassays for screening of products•Polishing behaviour of hull coatings•Foul release tests on rotor drums in seawater•Friction drag tests of coatings/ surfaces with and without fouling
•Long term dynamic ageing of hull coatings•Raft exposure studies, benchmarking
Microbiological effects on materials
Microbiology
Metallurgy
Direct observation (in-situ analysis)
Electrochemistry MIC
Diagnosis and risk assessment Microbial presence/activity Microbial corrosive metabolites Characterization of corrosion damage
(electrochemical, metallographic)
Monitoring In-situ, online detection techniques Offline analyses
Mitigation (prevention and treatment) System design recommendations (e.g. material selection, substrate pre-treatment, coatings,
anti-microbials, etc)
Endures operates from four different knowledge fields
Key underlying knowledge for ENDURES is understanding of the combined influence of environmental conditions on material degradation and structural durability. Based on this adequate mitigation measures are provided.
• Ferrous /non ferrous metals,
• Composites• Adhesive joints • Coatings• Cathodic protection
• Ageing• Biofilms• Biological and chemical degradation
• Physics• (Electro)Chemistry• Corrosion• Microbiology
• Operational costs• Sustainability• Safety
Life time extension
Fundamentalknowledge
on corrosion
PredictionMitigation
Monitoring
Knowledge
Gained from the past TNO
Build up now TNO, JIP, MIIP, TUDelft, NDLA, TU Duisburg
Future TNO, consortia, individual companies, TUDelft, NDLA, TU Duisburg
SEM-EDX AFM/ SKPFM
3D & Stereo microscope
Fluorescence microscope
Ship tank model
MIC cultures
Sensors
Electrochemical techniques
Staining techniques
Monopile modelin natural seawater
Some of Endures laboratory facilities
High pressure setup
Anaerobic glove box
Recommended