1
Independent Formal Verification of Safety-
Critical Systems’ User Interfaces:
a space system case study
NASA IVV Workshop
September, 2013
Manuel Sousa1, José Creissac Campos1
Miriam Alves2 and Michael D. Harrison3
1Dept. Informática/Universidade do Minho &HASLab/INESC TEC, Portugal
2Institute of Aeronautics and Space - IAE, São José dos Campos, Brazil
3Queen Mary University of London & Newcastle University, UK
* This work is funded by the ERDF - European Regional Development Fund through the ON.2 – O
Novo Norte Operational Programme, within the Best Case project (ref. N-01-07-01-24-01-26).
2
foreword
Dependable device
Dependable system?
User
The impact of users on a system is hard to anticipate
users behave in unexpected ways
users’ behaviour is changed by (adapts to) the device
users must understand the device
We have been working on approaches to consider the user
during the formal verification of interactive systems
3
VerificationPotentialProblem
Analysis
Modelling
Properties
Model
our approach
4
systematic analysis – the process
1. Models – system as designed
2. Property patterns – good design practices
3. Verification – models against patterns
4. Traces – when verification fails
Analysis
Scenarios
Prototyping
5. Change models – reflecting analysis findings
5
systematic analysis – the process
Scenarios
Prototype Model
Traces
abstraction
deployment
analysisverification
Expert analysis
Domain knowledge
Property Templates
Prototype
redesign
be
tte
r d
esig
n
Expert usability
inspection
Universal properties
/Heuristics
simulation
refinement
walkthroughs
techniques
process
information flow
6
the IVY tool
7
MAL interactors
interactor MCP
aggregates
dial(Altitude) via ALTDial
dial(ClimbRate) via crDial
dial(Velocity) via asDial
attributes
[vis] pitchMode: PitchModes
[vis] ALT: boolean
actions
[vis] enterVSenterIASenterAHtoggleALT
enterAC
axioms
[asDial.set(t)]effect(enterIAS)
[crDial.set(t)]effect(enterVS)
[ALTDial.set(t)] ensure_ALT_is_set
[enterVS] pitchMode'=VERT_SPD & ALT'=ALT
[enterIAS] pitchMode'=IAS & ALT'=ALT
[enterAH] pitchMode'=ALT_HLD & ALT'=ALT
[toggleALT] pitchMode'=pitchMode& ALT'=!ALT
[enterAC] pitchMode'=ALT_CAP & !ALT'
Behaviour
8
9
IAE’s PTGS
MN
Subsystem
SC
Subsystem
EV
Subsystem
PR
Subsystem
CR
Subsystem
Telemetry Time
Synchronization Operators Batteries
Operational
Communication
Operational
Signalization
INTERFACES UMBILICAL
CORDS
RO
CK
ET
PW
Subsystem
10
IVY analysis of EV subsystem
The system was modelled from the operations manual
model reflects knowledge provided to the operator
properties used to express expected behaviour
A three layered model was built
Each type of variable modelled as an interactor
Each screen modelled as an interactor
Navigation between screens modelled on top of that
Values displayed modelledas attributes
Buttons modelled as actions
11
From manual to model
How the colouring scheme works (from the operations manual):
“Blinking yellow: For a critical variable, when the current value of the variable is in non acknowledged alert (value within the alert range), there is no acknowledged alarm in the variable, and the previous criterion [non acknowledged alarm criterion] is not satisfied. If over the same critical variable an acknowledged alarm exists, then Fixed Red prevails. For a non critical variable, when the current value of the variable is in non acknowledged alarm (value within the alarm range).”
12
From manual to model
How the colouring scheme works (from the operations manual):
“Blinking yellow: For a critical variable, when the current value of the variable is in non acknowledged alert (value within the alert range), there is no acknowledged alarm in the variable, and the previous criterion [non acknowledged alarm criterion] is not satisfied. If over the same critical variable an acknowledged alarm exists, then Fixed Red prevails. For a non critical variable, when the current value of the variable is in non acknowledged alarm (value within the alarm range).”
critical & ((_v>= infAlarmLim& _v<infAlertLim) | (_v<= supAlarmLim& _v>supAlertLim)) & (alarmState != AlaRec&alarmState != AlaNRec)
13
From manual to model
How the colouring scheme works (from the operations manual):
“Blinking yellow: For a critical variable, when the current value of the variable is in non acknowledged alert (value within the alert range), there is no acknowledged alarm in the variable, and the previous criterion [non acknowledged alarm criterion] is not satisfied. If over the same critical variable an acknowledged alarm exists, then Fixed Red prevails. For a non critical variable, when the current value of the variable is in non acknowledged alarm (value within the alarm range).”
!critical& ((_v<infAlarmLim) | (_v>supAlarmLim))
14
From manual to model
[setValue(_v)](((critical & ((_v>= infAlarmLim& _v<infAlertLim) | (_v<= supAlarmLim
& _v>supAlertLim))) | (!critical & ((_v<infAlarmLim) | (_v>supAlarmLim)))) & (alarmState != AlaRec&alarmState != AlaNRec))
->value’ = _v&colour’ = yellow & error’ = Lim &alertState’ = AleNRec&characteristic’ = Blink &keep(supAlertLim,infAlertLim,supAlarmLim,
infAlarmLim,unity,critical,alarmState)
conditions for blinking yellow
settingblinking yellow
How the colouring scheme works (from the operations manual):
“Blinking yellow: For a critical variable, when the current value of the variable is in non acknowledged alert (value within the alert range), there is no acknowledged alarm in the variable, and the previous criterion [non acknowledged alarm criterion] is not satisfied. If over the same critical variable an acknowledged alarm exists, then Fixed Red prevails. For a non critical variable, when the current value of the variable is in non acknowledged alarm (value within the alarm range).”
15
From manual to model
(alarmState != AlaNRec&alarmState != AlaRec) becomes (alarmState = AlaRec)
How the colouring scheme works (from the operations manual):
“Blinking yellow: For a critical variable, when the current value of the variable is in non acknowledged alert (value within the alert range), there is no acknowledged alarm in the variable, and the previous criterion [non acknowledged alarm criterion] is not satisfied. If over the same critical variable an acknowledged alarm exists, then Fixed Red prevails. For a non critical variable, when the current value of the variable is in non acknowledged alarm (value within the alarm range).”
16
the model
17
analysis
Can a variable be in alarm?
Trying to prove otherwise…
False as expected but…
counterexample highlights a situation where the variable
colour is fixed red under an acknowledged alert condition –
should not be possible.
AG(monitTMT.BD1_A.colour = green -> !EX (monitTMT.BD1_A.colour = red))
18
analysis
manual not stating what happens to a non-critical alert
model becomes non-deterministic
19
conclusions/lessons learnt
It was possible to build a relevant model independently (without a deep understanding of the system) and still provide insights to the client
This particular model captures understanding of the system from the operations manual/requirements document perspective
Incomplete or inconsistent information leads to unexpected system behaviour
Computer-aided verification of user interfaces is crucial for critical-complex systems
Results can help:
improve requirements / manuals
define test cases
improve system dependability
As we add complexity to the models, verification time becomes a problem – but, interesting results are possible with manageable models
20
Thank you!jose.campos@di.uminho.pt