BS2 Hvac ventilation 1

Preview:

Citation preview

BUILDING SERVICES TWO (BLD60503)

HVAC Systems & Building

BUILDING | SERVICES | TWO (BLD60503)

Ventilation

Prepared by Tan Hee Chai

BUILDING | SERVICES | TWO (BLD60503)

Ventilation RequirementsThe effect of air on health and comfort depends upon:Movements;Humidity andTemperature

BUILDING | SERVICES | TWO (BLD60503)

BUILDING | SERVICES | TWO (BLD60503)

BUILDING | SERVICES | TWO (BLD60503)

Ventilation systemRatio Main Elements in Dry atmospheric

Oxygen 21%

Carbon dioxide 0.03%

Nitrogen NeonHelium HydrogenWater Vapour79%

BUILDING | SERVICES | TWO (BLD60503)

Ventilation Requirements

Air change important for two reasons:

1.Maintain a satisfactory level of oxygen content – essential for life2.To remove impurities

BUILDING | SERVICES | TWO (BLD60503)

Ventilation Requirements

BUILDING | SERVICES | TWO (BLD60503)Ventilation System

Rate of air change = ratio of fresh air supplied each hour to volume of the enclosed space

BUILDING | SERVICES | TWO (BLD60503)

Ventilation System Example: A private office of 30 m3 volume designed for 2 persons:Recommended m3/hour per person is 43

43/30 x 2 = 2.86 air change per hour

BUILDING | SERVICES | TWO (BLD60503)

Ventilation System

Ordinary conditions

Fresh air supply of 30 -35m3 per person per hour

• 1.5 air changes per hour for family of 4

Normal living room 45 m3:

BUILDING | SERVICES | TWO (BLD60503)

Ventilation System

BUILDING | SERVICES | TWO (BLD60503)

Ventilation SystemVentilation rates requirements:Normally based on recommendations by authorities or code of practice e.g:•Department of Occupational Safety & Health (DOSH)•Malaysian Standard Code of Practice

BUILDING | SERVICES | TWO (BLD60503)

Ventilation System

Apart from fresh air, movement of air over surface of body necessary to remove surplus •heat, •water vapour, •carbon dioxide and •organic vapours from body

BUILDING | SERVICES | TWO (BLD60503)Ventilation System

Desirable characteristics of atmosphere:•Cool •Dry •Diverse in temperature in different parts and at different times •Moving

Undesirable characteristics of atmosphere:•Hot•Damp•Uniform and Monotonous•Still

BUILDING | SERVICES | TWO (BLD60503)

Ventilation System

Desirable characteristics of atmosphere:•Air change•Proper means of ventilation

Undesirable characteristics of atmosphere:•Cubic space•Excessive cubic space

BUILDING | SERVICES | TWO (BLD60503)

Ventilation SystemVentilation principles:

To prevent undue concentrations of odours,

Bacteria carrying particles andNoxious gases

BUILDING | SERVICES | TWO (BLD60503)

Ventilation SystemVentilation principles:

To remove heat from products of combustionBody heat and heat from electrical equipment, motors, heat from solar radiation etc

BUILDING | SERVICES | TWO (BLD60503)

Ventilation SystemVentilation principles:

To remove fumes, dust etc produced by industrial process

BUILDING | SERVICES | TWO (BLD60503)Ventilation System

Ventilation principles:To maintain the relative humidity within reasonable limits

BUILDING | SERVICES | TWO (BLD60503)

Ventilation SystemVentilation principles:Percentage saturation = Weight of moisture in the air/weight of moisture if air were saturated at the same temperature x 100%Relative humidity (RH) = Vapour pressure of moisture present/ Vapour pressure if air were saturated at the same temperature x 100%

BUILDING | SERVICES | TWO (BLD60503)

Ventilation SystemVentilation principles: Relative Humidity

BUILDING | SERVICES | TWO (BLD60503)

Ventilation principles:

To create air movement

BUILDING | SERVICES | TWO (BLD60503)

Natural Ventilation

• Natural ventilation systems rely on pressure differences to move fresh air through buildings.

• Pressure differences can be caused by wind or the buoyancy effect created by temperature differences or differences in humidity.

BUILDING | SERVICES | TWO (BLD60503)

Natural Ventilation

BUILDING | SERVICES | TWO (BLD60503)

Pressure Patterns caused by wind

BUILDING | SERVICES | TWO (BLD60503)

Passive stack ventilation (PSV)

PSV Consist of Extract grilles at ceiling height Ducts to terminal at roof

BUILDING | SERVICES | TWO (BLD60503)

Passive stack ventilation (PSV) Types of vent

BUILDING | SERVICES | TWO (BLD60503)

Natural Ventilation System

BUILDING | SERVICES | TWO (BLD60503)

Building Regulation

Habitable or occupiable rooms located on an external wall

Requirements require a window

opening with permanent background ventilation

Natural Ventilation System

Non-habitable rooms in domestic buildings

Maybe ventilated mechanically or by passive stack ventilation system

BUILDING | SERVICES | TWO (BLD60503)

Building Regulation

Rooms with no openable windows in non-domestic buildings

Requirements Mechnical ventilated

or air-conditioning

Natural Ventilation System

Kitchen,bathrooms,utility rooms etc

Open window and mechanical extract ventilation or by passive stack ventilation system

BUILDING | SERVICES | TWO (BLD60503)

Mechanical Ventilation System

Artificial methods of preserving the purity and controlling the temperature of the atmosphere.

BUILDING | SERVICES | TWO (BLD60503)

Mechanical Ventilation System

Method: Extract Supply Combined extract and input

BUILDING | SERVICES | TWO (BLD60503)

Extractor fan system

BUILDING | SERVICES | TWO (BLD60503)

Extractor fan

BUILDING | SERVICES | TWO (BLD60503)

Extract system

• Cheap to install and operate• Definite volume of air is removed from

buildings• Air entering to replace cannot be controlled.• Draughts are created

BUILDING | SERVICES | TWO (BLD60503)

Supply system

BUILDING | SERVICES | TWO (BLD60503)

Supply system

BUILDING | SERVICES | TWO (BLD60503)

• Air delivered under pressure.

• Include air heater battery with automatic

control over temperature of air delivered

into rooms

• An air filtration device

Supply system

BUILDING | SERVICES | TWO (BLD60503)

• Easy to install in existing buildings• Can be included when designing new

building.• Eliminates draughts by building up

pressure inside the spaces

Supply system

BUILDING | SERVICES | TWO (BLD60503)

Combined supply & extract system with propeller fans

BUILDING | SERVICES | TWO (BLD60503)

Combined supply & extract system with propeller fans

BUILDING | SERVICES | TWO (BLD60503) Heat Exchanger

BUILDING | SERVICES | TWO (BLD60503) Heat Exchanger

BUILDING | SERVICES | TWO (BLD60503)

Mechanical Ventilation System

Components:FanFiltersDuctworkFire dampersDiffusers

BUILDING | SERVICES | TWO (BLD60503)

Mechanical Ventilation System

Types of Fan Cross-flow or tangential Propeller Axial flow Centrifugal

BUILDING | SERVICES | TWO (BLD60503)

Wall mounted propeller fan

BUILDING | SERVICES | TWO (BLD60503)

Axial-flow fan

BUILDING | SERVICES | TWO (BLD60503)

Bifurcated axial flow fan

BUILDING | SERVICES | TWO (BLD60503)

Centrifugal fan

BUILDING | SERVICES | TWO (BLD60503)

Centrifugal fan

BUILDING | SERVICES | TWO (BLD60503)

Centrifugal fan

BUILDING | SERVICES | TWO (BLD60503)

Cross-flow or tangential fan

BUILDING | SERVICES | TWO (BLD60503)

Filters

Dry Filter made of •Paper•Fine woven fabrics•Foamed plastics or fibreglass

BUILDING | SERVICES | TWO (BLD60503)

Dry Filters

BUILDING | SERVICES | TWO (BLD60503)

Filters

Viscous or Wet Filter made of •A bank or rows of corrugated metal sheets with surface coated in non-flammable, non-toxic odourless oil

BUILDING | SERVICES | TWO (BLD60503)

Viscous or Wet Filter

BUILDING | SERVICES | TWO (BLD60503)

Electrostatic Filterconsist of •Pre-filter•Power pack•Ioniser•Rows of opposing charged plates

BUILDING | SERVICES | TWO (BLD60503)

Electrostatic Filter

BUILDING | SERVICES | TWO (BLD60503)

Electrostatic Filter

BUILDING | SERVICES | TWO (BLD60503)

Activated carbon Filter

BUILDING | SERVICES | TWO (BLD60503)

Activated carbon Filter

made of •Disposable elements of glass fibrous matting containing charcoal granular

BUILDING | SERVICES | TWO (BLD60503)

BUILDING | SERVICES | TWO (BLD60503)

BUILDING | SERVICES | TWO (BLD60503)

Ventilation duct design

BUILDING | SERVICES | TWO (BLD60503)

Factors influencing the size of ducts for air transport are:

The volume of flow rate of the air The friction of the air against the walls of

the ducts and any turns and protrusions. The pressure available for the movement of

air.

BUILDING | SERVICES | TWO (BLD60503)

BUILDING | SERVICES | TWO (BLD60503)

Calculation of air volume flow rate:

Q = Room volume x air changes per hour/time in seconds

Where • Q is the volume of flow rate in

m3/s

Ventilation duct design

BUILDING | SERVICES | TWO (BLD60503)Ventilation duct design

BUILDING | SERVICES | TWO (BLD60503)

Ventilation duct design - Chart

BUILDING | SERVICES | TWO (BLD60503)

Ventilation duct design

BUILDING | SERVICES | TWO (BLD60503)Ventilation duct design

BUILDING | SERVICES | TWO (BLD60503)Ventilation duct design

BUILDING | SERVICES | TWO (BLD60503)

Ventilation duct design

BUILDING | SERVICES | TWO (BLD60503)

Ventilation Design – Duct conversion

BUILDING | SERVICES | TWO (BLD60503)

Ventilation Design – Duct conversion chart

BUILDING | SERVICES | TWO (BLD60503)

The End